background image

 

The JA-85B mini-size wireless glass-break detector

 

 

MHP52600_OS1_c1_FCC 

The JA-85B mini-size wireless glass-break detector 

 
The  JA-85B  is  a  component  of  Jablotron’s  Oasis  80  alarm  system.  The 
glass-break detector uses the analysis of air pressure variations combined 
with the characteristic sound of glass breaking and it is designed for indoor 
use in buildings or in cars. The battery-powered detector communicates via 
OASIS radio protocol.

 

open here

+

lithium 
battery
AA 3V 

A

A

 3

V

PCB

release

LED

1

2

DIP switches
- see table

secure

d (C

LIC

K

)

 

 

Installation 

 

Installation  shall  only  be  undertaken  by  technicians  holding  a  certificate 
issued by an authorized distributor. The detector can be installed on a wall 
or  on  a  ceiling.  In  a  car  it  can  be  under  a  dashboard.  Because  of  its 
sensitivity  to  air  pressure  changes  and  sounds  it  should  not  be  located 
close to air conditioning or ventilation outlets. There should be no sources 
of vibration or audible sounds in the protected area. There should also be 
no obstacles blocking the detector’s “listening” to the protected area. Keep 
the  detector  away  from  metal  objects  which  could  interfere  with  radio 
communication. 
Warning:  The  most  frequent  cause  of  false  alarms  is  bad  detector-
positioning. 
Do not set (arm) this detector if there are any people or pets moving within 
the protected area. 

1. 

Release the detector installation bracket (by turning it clockwise)   

2. 

Attach  the  bracket  to  the  desired  place  and  reinstall  the  detector 
onto the bracket. 

3. 

Open the detector cover by pressing the tab  

4. 

Remove the internal board held by an internal tab. 

5. 

Set  the  detector  DIP  switches  (see  the  “DIP  switches”  section 
below) 

6. 

Return the board into the plastic cover. 

7. 

Leave  the  battery  disconnected  and  the  detector  open  and  then 
follow  the  receiver  (or  control  panel  or  car  alarm)  manual.  The 
detector  enrolls  by  connecting  up  its  battery  while  the  receiver  is  in 
enrollment mode. 

8. 

After  detector  enrollment,  close  its  cover,  wait  until  its  indicator 
turns off and then test its functionality and adjust its sensitivity. 

To  enroll  a  detector  after  having  already  connected  the  battery,  first 
disconnect the battery, wait 30 seconds and reconnect it. 

 

 

DIP switches 

OFF 

ON 

1* 

Radio comms. supervision off 

Radio comms. supervision on 

2** 

Delayed natural reaction   

Instant natural reaction   

*  Radio  communication  supervision  should  be  switched  off  if  a  detector 

installed  in  a  car  is  enrolled  to  an  Oasis  control  panel  in  a  house  (to 
avoid lost detector indication when the car drives away). 

**  This DIP switch has an effect if the detector is used with a CA car alarm 

or with an Oasis control panel which has a natural reaction assigned to 
the JA-85B’s address. It has no effect when used with a UC-8x or AC-8x 
receiver. 

 

 

 

 

 

 

Testing the detector  

15  minutes  after  closing  the  detector  cover,  the  LED  shows  detector 
triggering as follows: 

Short flash = air pressure change (glass deformation) 

Long flash = glass-break detection (alarm)   

Adjusting the sensor: 

  Using a suitable tool or a hand protected by gloves, one by one, knock 

all  the  windows  that  should  be  under  the  detector’s  protection.  A 
visible deformation of the glass should occur but without any damage. 

  The  deformation  of  glass  causes  a change  in  the  air  pressure  of  the 

room which makes the LED on the detector flash quickly.  

  Sensitivity to air pressure changes can be adjusted by a potentiometer 

on  the  PCB.  Turning  clockwise  increases  sensitivity.  Avoid  selecting 
too high a sensitivity as this can cause a short battery lifetime. 

  The  complete  function  of the  detector  can  be  tested  with  a  GBT-212 

glass-break  simulator.  After  knocking  the  glass,  this  simulator  will 
automatically  generate  the  characteristic  sound  of  breaking  glass  to 
create the conditions for detector triggering. 

 

If  there  are  any  devices  in  the  detector’s  protected  area  generating 
sound  such  as  air  conditioning,  heating,  fax  machines,  refrigerators, 
etc., check that they are not triggering alarms by emitting sounds like 
breaking glass.

  

 

Battery replacement 

The  detector  battery  is  regularly  checked.  If  the  battery  has  expired, 

then  the  user  or  installer  is  informed.  The  detector  continues  to  work 
and  each  air  pressure  change  is  shown  by  a  brief  LED  flash.  The 
battery should be replaced within two weeks by a qualified technician.   

After battery replacement, the detector needs two minutes to stabilise 

during  which  the  LED  is  permanently  lit.    After  battery  replacement, 
test  the  functioning  of  the  detector.  An  expired  battery  should  not  be 
thrown into the garbage, but disposed of according to local regulations. 

 

 

Detection characteristics of the sensor  

The  directional  response  of  the  glass-break  sensor  has  a  near-spherical 
characteristic  and  it  is  possible  to  detect  breaking  glass  up  to  9  metres 
away as can be seen in the below diagram. The size of glass should be at 
least  60  by  60  cm.  For  smaller  sizes  the  detection  range  can  be  shorter. 
Only breaking glass forming part of the walls within the protected area can 
be detected. All kinds of glass can be protected including windows covered 
with unbreakable folio. 

Warning: This type of detector is not suited to sensing holes being cut 
through  glass  by  glass  cutters.  For  this  reason,  valuables  near 
windows should be covered by PIR sensors. 
 

 

 

 

Detector relative directional sensitivity 

 

Technical specifications 

 

Voltage 

Lithium battery type CR14505 (AA 3.0V) 

Calculated battery lifetime 

approx. 3 years (sleep time 5 min.) 

Communication band: 

868 MHz, Oasis protocol 

Communication range: 

approx. 100m (open area) 

Detection range: 

up to 9 m 

Operational environment according to EN 50131-1  

II. internal space 

Operational temperature range 

-10 to +40 °C 

Dimensions 

88 x 46 x 22 mm 

EN 50131-1, CLC/TS 50131-2-2, EN 50131-5-3 classification: 

grade 2  

Complies with 

 ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1

,   

ANSI C63.4 

Can be operated according to

  

ERC REC 70-03, FCC Part 15 

FCC ID VL6JA85B 
 

Jablotron Ltd. hereby declares that the JA-85B is in compliance 
with  the  essential  requirements  and  other  relevant  provisions  of 
Directive  1999/5/EC 

and  complies  with  part  15  of  the  FCC  rules. 

Operation  is  subject  the  the  following  two  conditions:  1.  This  device 

may not cause harmful interference, and  2. this device must accept any 
interference  received,  including  interference  that  may  cause  undesired 
operation. 

 The  original  of  the  conformity  assessment  can  be  found  at 

www.jablotron.com

,  Technical  Support  section

  CAUTION:  Changes  

or  modifications  no  expressly  approved  by  Jablotron  could  void  the  user´s 
authority to operate the equipment

 

 

Отзывы: