jablotron JA-82Y Скачать руководство пользователя страница 1

The JA-82Y GSM communicator installers manual 

1/13 

MDL51109 

 
 

The JA-82Y GSM communicator

 

The communicator is a component of the Jablotron Oasis 80 system. It has been 
designed for communication via a GSM network. It is installed directly  within the 
OASIS control panel housing and it allows the following: 

 event reporting by SMS (for up to 8 telephone numbers) 

 event reporting by phone call with voice message warnings (it is possible to 

record up to 7 messages for various events)  

 remote control and programming by phone (by calling and using the voice 

menu or by SMS instructions) 

 remote control of the system (or appliances in the house) by dialling in from 

an authorized number (free of charge )  

 remote control and programming of the system via the Internet  (

It is  not 

possible to register the communicator on www.gsmlink.cz) 

 data transmission to an Alarm Receiving Centre (ARC) - up to 2 ARCs 

 sending photos from JA-84P detectors to a secure server 

 updating communicator firmware, language and new text sets using OLink 

2.0 software or higher  

1.  Installation in the control panel 

If you purchased the communicator module separately, it should first be installed in 
the OASiS control panel as follows: 
 
The control panel 

power must be switched o

ff (both mains and battery) 

Fit the communicator inside the control panel housing using screws and 

connect 

its cable

 to the main board. 

Attach the adhesive GSM antenna inside the control panel’s plastic housing (it can 
be  glued  in  a  suitable  place)  and  connect  the  antenna  to  the  communicator. 

Warning: never switch the control panel power on if the GSM antenna is not 
connected to the GSM module as this will cause serious damage!!!

 

 

fig. 1 Communicator description: 

 1.LED  signalling  connection  to  a  GSM  network;  2.LED  signalling  image 
transmission; 3. control panel connector; 4. GSM connector; 5. SIM card 

2.  Initial powering up of the communicator 

1. 

The  communicator  is  installed  in  the  control  panel  and  its  GSM 
antenna is connected, then: 

2. 

Have a suitable SIM card ready

. It should be activated (see if it works 

in a mobile phone first). If it requires a PIN code  when switching the 
phone on, 

then disable the PIN code request upon the first use of 

the phone

); e.g.  Nokia: Menu / Settings / Security settings / PIN code 

request / Off. The communicator can work with a prepaid card, but we 
recommend using a tariff card for more reliable functioning 

3. 

Insert the  SIM card

 into the communicator (to open the card holder 

push its frame up a little) 

4. 

Switch  on  the  control  panel  power  (both  mains  and  battery).  The 
commu

nicator’s  red  LED  should  be  lit  =  registering  to  the  GSM 

network; 

it should go off within a minute = registration successful

 

5. 

 If the red LED starts flashing after a while, switch off the control panel 
power, put the SIM card into a mobile phone and check that it registers 
to the network in the place where the control panel is installed without 
any PIN code requests 

6. 

Close the control panel cover

, the alarm system should be in Service 

mode - if it is not, enter *0 Service code (Factory default setting: 8080) 
with the alarm system unset (disarmed) 

7. 

Key  in 

99101

  -  to  set  the 

texts

  and  voice  messages  of  the 

communicator 

to the English language

 

8. 

Key in 888 to measure the GSM signal strength (a number in the range 
from 1/4 to 4/4 should be displayed). It should be at least 2/4 to ensure 
reliable  functioning.  If  the  signal  is  weak,  change  the  location  of  the 
control  panel  or  try  a  SIM  card  from  another  GSM  provider  (it  is  not 
recommended to use either a high-gain or directional GSM antenna 

– 

see 6.2 GSM signal strength measuring) 

9. 

If the GSM signal strength is sufficient, test the communicator functions 
(system control via a mobile phone, etc), see the instructions below 

Warning:  If  installed  at  a  location  near  a  national  border  where  the  signal 
strength  fluctuates,  roaming  to  a  foreign  network  is  highly  likely.      We 
therefore recommend blocking the roaming feature in the SIM card to avoid 
unnecessarily  high  communication  fees  (contact  your  GSM  provider  for 
details).

 

3.  User functions of the communicator 

The following text describes all communicator features. The installer should show 
the end user how to operate the functions used in the particular installation. 

3.1. 

Event reporting to the user’s phone  

The  communicator  reports  events  in  the  OASiS  system  by  sending  a  text  SMS 
and / or calling and transmitting a voice message. Reporting can be set to up to 8 
telephone numbers. The most frequently used report variants are preset but they 
can be customized 

Notes:  

 

If  used,  transmissions  to  the  Alarm  Receiving  Centre  have  absolute 
transmission priority (see 7.4).
 

 

Calling is usually used to draw the user’s attention to a detailed report sent in 
an SMS. If reporting by SMS is enabled, the communicator first sends all SMS 
messages before it starts dialling the set numbers.  

 

Message  playing  can  be  terminated  by  pressing  *  on  the  telephone  keypad. 
The keypad then switches into keypad simulation mode and the messages are 
not further transmitted to other numbers. 

3.2. Temporarily authorizing a phone as a system keypad 

It is possible to operate the system remotely  by temporarily  authorizing a phone 
keypad as follows: 
Dial the communicator’s SIM card number. 
After 15 seconds of ringing, the system will answer with  a voice menu welcome 
message and ask for a code. 
Key in a valid control panel access code on the telephone keypad 

–the  master 

code (default 1234), a user code or possibly the service code (default 8080). 
Once the code has been entered, the voice menu offers the basic system functions 
(see 10). 
To exit this mode simply end the phone call.  If nothing is entered within a minute, 
the phone call will end automatically anyway. 
The maximum allowed phone call length is 30 minutes. 

Notes: 

 

a  fixed-line  phone  can  also  be  used  to  operate  the  system  remotely  in    the 
same way. The phone must use tone dialling (DTMF).  

 

do  not  enter  sequences  on  the  phone  too  fast

,  each  key  signal  needs  a 

certain time to be sent (it depends on the particular phone and the quality of the 
GSM connection 

3.3. SMS instructions to control the system remotely 

All  incoming  SMSes  are  checked  by  the  communicator  and  if  there  are  any 
instructions to the system, they will be performed. Each instruction message must 
have the following format:: 

code_instruction 

(i.e. valid code space instruction) 

Valid code = any valid code in the system (e.g.  8080, 1234) 

The factory-default instruction texts (editable 

– see TXT command) 

Command 

Function 

Note 

SET 

setting (arming) 

setting or unsetting (the same way as if the 
used code is entered on the system keypad), 
If the system is already in the desired mode, 
it will not change 

UNSET 

unsetting 

(disarming) 

STATUS 

reports system 

status 

including GSM signal strength, GPRS 
connection and ARC communication (shown 
as MS1, MS2 and MS3) 

MEMORY 

reports latest 

events 

this concerns the last 3 events from the 
control panel memory 

PGX ON 

turns on PGX 

the PG output has to be programmed for the 
function: on/off (by 237/247) or 2 second 
switching (by 238/248) 

PGX OFF 

turns off PGX 

PGY ON 

turns on PGY 

PGY OFF 

turns off PGY 

CREDIT 

SIM card credit 

inquiry 

it has to be initialized before it can be used 

– 

see 6.21 

DINFO 

SMS info about 

device version 

SMS on assembly,  firmware, and hardware 
versions, reg. key, remote access code via 
OLink 

Tab. 1 SMS commands 

Example by sending: “code SET” (valid code space SET) the system will set (if it is 
already set it will not change its status) 

Notes: 

 

the system will confirm performance of the SMS instruction by an SMS reply, if 
this function is allowed   

 

the SMS instruction texts are not case-sensitive and only ASCII characters are 
allowed 

 

the SMS instruction texts can contain multiple instructions separated with a comma   

 

if you are sending an instruction and you are not sure whether any other text 
will  be  automatically  added  to  the  SMS  (for  example,  when  using  an  SMS 
internet gate) type the instruction as:   %code instruction%%  

 

the valid code can also be entered automatically, see 6.6. 

Содержание JA-82Y

Страница 1: ...commend blocking the roaming feature in the SIM card to avoid unnecessarily high communication fees contact your GSM provider for details 3 User functions of the communicator The following text describes all communicator features The installer should show the end user how to operate the functions used in the particular installation 3 1 Event reporting to the user s phone The communicator reports e...

Страница 2: ...M8 To program phone numbers to the M memories enter the following sequence while in Maintenance Service mode 81 M xxx x y 0 where M is memory number 1 to 8 xxx x is a telephone number max 20 digits y is a sequence for control via unanswered calls it does not have to be entered In a split system information from all sections ABC is reported to the 1st and 8th number positions sections AC to numbers...

Страница 3: ...2 is programmed the code 2222 will be automatically inserted in an SMS with instructions sent from the first number stored in the memory Factory default setting No code 6 7 Allowing remote access for telephone numbers Remote access is allowed for numbers saved in positions 1 to 8 Programming sequence 85 M x where M memory position tel numbers 1 to 8 x parameter 1 to allow access parameter 0 to den...

Страница 4: ...ation off 907 1 synchronization on Factory default settings on 6 18 Phone receiver loudness To set the loudness of the receiver of the phone which is used to call the communicator key in 909 x where x is a number from 1 to 9 max Factory default setting 9 max 6 19 Number to be called to maintain SIM card validity If a prepaid SIM card is used and a lack of outgoing phone calls for a certain period ...

Страница 5: ...o the communicator turn on the control panel power and then enter the correct PIN code 920 PIN 0 and wait until the communicator registers to the GSM network its red LED should turn off within a minute The communicator memorizes the set PIN and it will use it automatically whenever it registers to the GSM network again If you are replacing the SIM card in the communicator with another one and the ...

Страница 6: ... 97 Low SIM card credit balance Not reported 50 SMS transmission from a line e g from JA 84P Not reported 51 ARC communication failure 1354 reported 52 ARC communication restored 3354 reported 53 tab 3 ARC event table Source Name 701 Control panel 731 Communicator 741 Keypad 001 050 Device 1 Device 50 500 Master code 599 Service code 501 550 Code 1 code 50 tab 4 Source number table The report to t...

Страница 7: ...ated by green LED 1 being permanently lit on the left under the SIM card holder see fig 1 Communicator description Transmission to the server is signalled by a flashing green LED Successful transmission is confirmed by a long green LED flash and unsuccessful transmission is reported by rapid flashes of the green LED Successful transmission from the GSM communicator to the server is confirmed by a ...

Страница 8: ...ed in position 0 by the sequence 81 0 xxx x 0 xxx x own telephone number If you change the SIM card position 0 will be automatically erased Time synchronization see section 6 17 of the control panel is performed whenever entering into service mode or maintenance mode and if there is a difference greater than 5 minutes between the correct time and control panel time synchronization is performed aut...

Страница 9: ... Incoming call Welcome to OASiS Enter your access code Valid code CODE Can t perform the operation Enter your access code OK Invalid Valid Disarmed system Press 1 to arm OK System Armed Armed system Press 2 to disarm OK System disarmed Service mode If the system is in the requested state terminate the call The 9 key pressed Keypad simulation ...

Страница 10: ...witching to service maintenance mode 7 other event 66 Exiting service maintenance mode 7 other event 67 End of alarm indication 7 other event 78 Alarm cancelled by user S S S S S S S 7 other event 79 Control panel reset 7 other event 80 All tampers on standby 7 other event 81 All faults removed 7 other event 82 System power supply OK 7 other event 83 The communicator has no connection 5 fault 84 C...

Страница 11: ... 702 Finish setting 406 Service mode 529 Internal communication error 703 Signal strength 407 Maintenance mode 530 Internal communication restored 704 Control 409 Battery discharged 531 Communication test 705 Bypass 410 Tamper alarm 532 Unconfirmed alarm 706 Test OK 411 Alarm memory 533 Blocking after an alarm 707 Test error 412 Fault 534 Unblocking after an alarm 708 0 4 413 Power supply fault 53...

Страница 12: ...abled Enabling remote access 802 x x 0 no x 1 yes by phone and Internet x 2 yes but only by enrolled phones 1 yes Forwarding of incoming SMS messages 801 x x 0 no x 1 if the incoming text is not an SMS instruction it will be forwarded to the first programmed number in memories M1 to M8 yes Autoconfiguration of GPRS 903 x X 0 autoconfiguration disabled x 1 autoconfiguration enabled Autoconfiguratio...

Страница 13: ...vent code see 7 4 x 1 report x 0 no report All events are reported see tab 3 Periodic or fixed ARC connection check 06 p x p 1 ARC1 p 2 ARC2 x 0 with a period from the last report according to the 07 p hhmm setting x 1 once a day at the time set by entering 07 p hhmm With a period after the last report X 0 ARC communication checking period 07 p hhmm p 1 ARC1 p 2 ARC2 hhmm hours minutes see setting...

Отзывы: