The JA-80E  hard-wired keypad 

2 / 2 

MHE51203 

The JA-80E hard-wired keypad

The JA-80E is a component of Jablotron’s OASiS alarm system and is 
designed to control and program the system. It has a built-in proximity access 
card reader and allows the wiring up of a separate door detector. The keypad 
should be wired to the control panel.

  

 

Installation 

Installation shall only be undertaken by technicians holding a certificate 

issued by an authorized distributor. The keypad is for indoor installation only, 
typically by a main entrance door.  

1. 

Open the keypad housing 

(by pressing the tab on the bottom) and 

disconnect the inter-housing connection cable inside (by pulling the 
connector from the board). 

2. 

Install the rear housing 

to the desired location. 

3. 

Connect the control panel bus cable. There are two possibilities

Use a twisted-pair cable (max. 100m) for keypad installation. The 
correspondingly marked terminals in the keypad unit and in the control 
panel should be connected together (GND, A, B, +U). 

Use a flat four-cord telephone cable with RJ connectors (max. 10 
metres) for temporary (test) installation. There is a digital bus connector 
in the control panel, and in the keypad too. The keypad’s digital bus 
connector is supplied in the package and must be wired to the circuit 
board (remove a blind flange from the rear plastic and route the wires 
through the hole). 

4. 

Install the external door detector 

(if required)

 

and connect its cable to 

the IN and GND terminals. 

5. 

Connect the inter-housing cable 

to the keypad board.  Attach the keypad 

to the rear housing. 

6.  Keypad operating instructions are found in the control panel manual. 

 

OASIS 80

A     

B     

C

ABC

?

B

A

IN

GND

+U

B

A

GND

GN

D

A

B

+U

digital bus

cable

OASIS 80

A     

B     

C

ABC

?

B

A

 

 

Keypad menu – language selection and door bell function 

If the 

∗ 

 key is kept pressed while is being powered-up the internal keypad 

menu will be displayed allowing the selection of the 

desired language

. Using 

the arrows choose your language and confirm selection by the 

∗ 

 key. 

In this menu the 

door bell function 

can also be enabled or disabled (if 

enabled the keypad makes a sound when its IN input is triggered). 

To exit the menu, press 

(exiting also occurs after 10 seconds’ inactivity). 

Notes: 

• 

The keypad power can be switched on by connecting the bus cable or by 
switching on the control panel power. 

• 

Each keypad has its own menu, i.e. each keypad in the system can have 
its own unique settings. 

• 

The keypad keeps its settings even if its power is disconnected (settings 
can only be altered via the keypad menu). 

 

Three minute time-out of displaying the alarm status  

To comply with EN standards the keypad does not indicate the status of the 

alarm system while the system is set (armed). Indication only returns when the 
keypad is operated or an entrance delay is triggered. It is however possible to 
program permanent indication via the control panel, if considered appropriate. 

 

Installing a door detector 

It is possible to wire up a detector(s) to the keypad via the IN input. The IN 

input terminal is triggered when disconnected from GND. The control panel’s 
natural reaction to the IN input being triggered is a delayed intruder alarm 
(unchangeable reaction).    

Notes: 

 

• 

If the IN input is not used, connect it to GND. 

• 

The IN input only reports to the control panel at the moment of being 

triggered (a so-called pulse reaction, which means that the keypad 
cannot signal permanently open doors). The input belongs to the C 
section (can not be changed) and if there is more than one JA-80E in 
the system their inputs IN are not distinguished by the system.  

 

OASIS 80

A     

B     

C

ABC

?

B

A

IN

GND

+U

B

A

GND

 

An example of door detector wiring 

 

Disabling the tamper sensor 

To disable the tamper sensor, short out the jumper in the keypad unit close 

to the tamper sensor (equipped with a spring). This is useful when carrying the 
keypad unit around with a long cable while servicing the system. During 
normal system use this jumper 

must remain open circuited 

 

 

Keypad text editing  

There are two kinds of text: device and code names (displayed on the 

second line after the address number), and other system text. 

The names can be edited via the keypad after pressing and holding the 

key 

in service mode – see the control panel installation manual. The edited text is 
only stored in the keypad unit used for editing.  

If you use a PC running OLink software to set the texts, you will set the texts 

in all connected keypads.  

If you add a new keypad to the system, you can transfer (synchronize) all the 

latest texts to the keypad by using OLink to read the texts from the control 
panel. (OLink reading the control panel texts triggers the keypad into listening 
in to the bus and copying the texts into itself). 

The texts can only be copied  into the keypad but cannot be read out of it. 

 

Technical specifications 

Power 

via the control panel bus 

Standby consumption 

30mA 

RFID  cards 

Jablotron PC-01 or PC-02 (EM UNIQUE 125kHz) 

Length of digital bus cable 

max. 100m 

Door detector input 

IN = normally closed loop 

Dimensions  

113 x 121 x 63 mm 

Environment according to EN 50131-1  

II. internal 

Operating temperature range 

-10 to +40 °C 

EN 50131-1 and CLC/TS 50131-3 classification 

 class 2 

FCC ID VL6JA80E  

 
 

 

Jablotron Ltd. hereby declares that the JA-80E is in compliance 
with the essential requirements and other relevant provisions of 
Directive 1999/5/EC and complies with part 15 of the FCC rules. 
Operation is subject to the following two conditions: 1. This device 
may not cause harmful interference, and 2. This device must 
accept any interference received, including interference that may 
cause undesired operation. 

CAUTION

: Changes or modifications not expressly approved by 

Jablotron could void the user´s authority to operate the equipment.
The original of the conformity assessment can be found on the web 
site 

www.jablotron.com

, Technical Support section. 

 

Note: Although this product 
does not contain any harmful 
materials we suggest you return 
the product to the dealer or 
directly to the manufacturer 
after use.

 

 

Отзывы: