Digital communicator JA-65X
5/7
MFM53103
Note: Changing of a phone number erases the internal
communicator’s memory of non reported events and sends a
“Reset“ reporting code (051) to the Monitoring Station.
Factory setting:
both numbers are erased
4.6
Digital communicator reset
sequence:
096060
By entering this code the factory default settings of all parameters
are restored in the digital dialer. All phone numbers, reporting
codes, account codes etc. are erased. This reset doesn’t effect
the voice dialer’s settings. The reset sequence is:
0 9 6060
Note: All communicator settings are stored in non-volatile memory
and remain unchanged even after switching off the power supply.
5 Central Monitoring station report
codes table
A two digit report code
rc
(00 to FFh) can be set for every event.
If 00 is programmed as a report code, that event will not be
reported.
The major events group is marked by
Rc.
When formats 3/1 or
4/1/1 are used, only 16 of these major events are reported to
the Monitoring Station. This makes it necessary to only
program the
R
digits. The second digit does not count. Zero
can not be used in the pulse protocols. For Contact ID
protocol, program code 11 for major events (
Rc
) which you
want to report and the system will generate all details
regarding the event automatically including the events source
details (see part 5.1).
N.
Event
Code
001 Arming with remote control N.1
Rc
002 Arming with remote control N.2
Rc
003 Arming with remote control N.3
Rc
004 Arming with remote control N.4
Rc
005 Arming with remote control N.5
Rc
006 Arming with remote control N.6
Rc
007 Arming with remote control N.7
Rc
008 Arming with remote control N.8
Rc
009 Arming with master code
Rc
010 Arming with user code N.1
Rc
011 Arming with user code N.2
Rc
012 Arming with user code N.3
Rc
013 Arming with user code N.4
Rc
014 Arming with user code N.5
Rc
015 Arming with user code N.6
Rc
016 Arming with user code N.7
Rc
017 Arming with user code N.8
Rc
018 Arming with user code N.9
Rc
019 Arming with user code N.10
Rc
020 Arming with user code N.11
Rc
021 Arming with user code N.12
Rc
022 Arming with user code N.13
Rc
023 Arming with user code N.14
Rc
024 Partial arming
Rc
025 Quick arming without code
Rc
026 Disarming with remote control N.1
Rc
027 Disarming with remote control N.2
Rc
028 Disarming with remote control N.3
Rc
029 Disarming with remote control N.4
rc
030 Disarming with remote control N.5
rc
031 Disarming with remote control N.6
rc
032 Disarming with remote control N.7
rc
033 Disarming with remote control N.8
rc
034 Disarming with master code
rc
035 Disarming with user code N.1
rc
036 Disarming with user code N.2
rc
037 Disarming with user code N.3
rc
038 Disarming with user code N.4
rc
039 Disarming with user code N.5
rc
040 Disarming with user code N.6
rc
041 Disarming with user code N.7
rc
042 Disarming with user code N.8
rc
043 Disarming with user code N.9
rc
044 Disarming with user code N.10
rc
045 Disarming with user code N.11
rc
046 Disarming with user code N.12
rc
047 Disarming with user code N.13
rc
048 Disarming with user code N.14
rc
049 Entering of the programming mode
Rc
050 Exiting the programming mode
Rc
051 Communicator Reset
Rc
052 Initial AC powering
Rc
053 Alarm after initial AC powering
Rc
054 General battery trouble
Rc
055 General battery trouble end
Rc
056 Control panel battery trouble
Rc
057 Control panel battery trouble end
Rc
058 Zone alarm 1
Rc
059 Zone alarm 2
rc
060 Zone alarm 3
rc
061 Zone alarm 4
rc
062 Zone alarm 5
rc
063 Zone alarm 6
rc
064 Zone alarm 7
rc
065 Zone alarm 8
rc
066 Zone alarm 9
rc
067 Zone alarm 10
rc
068 Zone alarm 11
rc
069 Zone alarm 12
rc
070 Zone alarm 13
rc
071 Zone alarm 14
rc
072 Zone alarm 15
rc
073 Zone alarm 16
rc
074 Wrong access code alarm
Rc
075 Zone tamper 1
Rc
076 Zone tamper 2
rc
077 Zone tamper 3
rc
078 Zone tamper 4
rc
079 Zone tamper 5
rc
080 Zone tamper 6
rc
081 Zone tamper 7
rc
082 Zone tamper 8
rc
083 Zone tamper 9
rc
084 Zone tamper 10
rc
085 Zone tamper 11
rc
086 Zone tamper 12
rc
087 Zone tamper 13
Rc
088 Zone tamper 14
Rc
089 Zone tamper 15
Rc
090 Zone tamper 16
Rc
091 Keypad tamper
Rc
092 Control panel tamper
Rc
093 Siren tamper
Rc
094 Zone fault 1
Rc
095 Zone fault 2
Rc
096 Zone fault 3
Rc
097 Zone fault 4
Rc
098 Zone fault 5
Rc
099 Zone fault 6
Rc
100 Zone fault 7
Rc
101 Zone fault 8
Rc
102 Zone fault 9
Rc
103 Zone fault 10
Rc
104 Zone fault 11
Rc
105 Zone fault 12
Rc
106 Zone fault 13
Rc
107 Zone fault 14
Rc
108 Zone fault 15
Rc
109 Zone fault 16
Rc
110 Keypad fault
Rc
111 Control panel fault
Rc
112 Siren fault
Rc
113 Zone alarm end 1
Rc
114 Zone alarm end 2
Rc
115 Zone alarm end 3
Rc
116 Zone alarm end 4
Rc
117 Zone alarm end 5
Rc
118 Zone alarm end 6
Rc
119 Zone alarm end 7
Rc
120 Zone alarm end 8
Rc
121 Zone alarm end 9
Rc
122 Zone alarm end 10
Rc
123 Zone alarm end 11
Rc
124 Zone alarm end 12
Rc
125 Zone alarm end 13
Rc
126 Zone alarm end 14
Rc
127 Zone alarm end 15
Rc
128 Zone alarm end 16
Rc
129 Zone tamper end 1
Rc
130 Zone tamper end 2
Rc
131 Zone tamper end 3
Rc
132 Zone tamper end 4
Rc
133 Zone tamper end 5
Rc
134 Zone tamper end 6
Rc
135 Zone tamper end 7
Rc
136 Zone tamper end 8
Rc
137 Zone tamper end 9
Rc
138 Zone tamper end 10
Rc
139 Zone tamper end 11
Rc
140 Zone tamper end 12
Rc
141 Zone tamper end 13
Rc
142 Zone tamper end 14
Rc
143 Zone tamper end 15
Rc
144 Zone tamper end 16
Rc
145 Keypad tamper end
Rc
146 Control panel tamper end
Rc
147 Siren tamper end
Rc
148 Zone fault end 1
Rc
149 Zone fault end 2
Rc
150 Zone fault end 3
Rc
151 Zone fault end 4
Rc
152 Zone fault end 5
Rc
153 Zone fault end 6
Rc
154 Zone fault end 7
Rc
155 Zone fault end 8
Rc
156 Zone fault end 9
Rc
157 Zone fault end 10
Rc
158 Zone fault end 11
rc
159 Zone fault end 12
rc
160 Zone fault end 13
rc
161 Zone fault end 14
rc
162 Zone fault end 15
rc
163 Zone fault end 16
rc
164 Keypad fault end
rc
165 Control panel fault end
rc
166 Siren fault end
rc
167 Telephone line trouble
Rc
168 Telephone line trouble end
Rc
169 Control panel failure
Rc
170 End of control panel failure
Rc
171 Periodic test (24 hr. from last com.)
Rc
172 AC failure (in 30 min. after failure)
Rc
173 AC failure end
Rc
174 RF jamming
Rc
175 Wrong code alarm end
Rc
176 RF jamming end
Rc
177 Panic alarm from remote control N.1
Rc
178 Panic alarm from remote control N.2
rc
179 Panic alarm from remote control N.3
rc
180 Panic alarm from remote control N.4
rc
181 Panic alarm from remote control N.5
rc
182 Panic alarm from remote control N.6
rc
183 Panic alarm from remote control N.7
rc
184 Panic alarm from remote control N.8
rc
185 Master code panic alarm
rc
186 User code panic alarm
rc
187 Panic alarm end from rem. contr. 1
Rc
188 Panic alarm end from rem. control N.2 rc
189 Panic alarm end from rem. control N.3 rc
190 Panic alarm end from rem. control N.4 rc
191 Panic alarm end from rem. control N.5 rc
192 Panic alarm end from rem. control N.6 rc
193 Panic alarm end from rem. control N.7 rc
194 Panic alarm end from rem. control N.8 rc
195 Master code panic alarm end
rc
196 User code panic alarm end
rc
197 Subsystem panic alarm
Rc
198 Subsystem panic alarm end
Rc