background image

Digital communicator JA-65X 

5/7 

MFM53103 

 

Note: Changing of a phone number erases the internal 

communicator’s memory of non reported events and sends a 

“Reset“ reporting code  (051) to the Monitoring Station. 

Factory setting:

 both numbers are erased 

 

4.6 

Digital communicator reset 

 

sequence:

 096060

 

By entering this code the factory default settings of all parameters 

are restored in the digital dialer. All phone numbers, reporting 

codes, account codes etc. are erased. This reset doesn’t effect 

the voice dialer’s settings. The reset sequence is:  

0 9 6060

 

Note:  All communicator settings are stored in non-volatile memory 

and remain unchanged even after switching off the power supply. 

5  Central Monitoring station report 

codes table 

 

A two digit report code 

rc 

(00 to FFh) can be set for every event. 

If 00 is  programmed as a report code, that event will not be 

reported.  

The major events group is marked by 

Rc. 

When formats 3/1 or 

4/1/1 are used, only 16 of these major events are reported to 

the Monitoring Station. This makes it necessary to only 

program the

  R 

digits. The second digit does not count. Zero 

can not be used in the pulse protocols. For Contact ID 

protocol, program code 11 for major events (

Rc

) which you 

want to report and the system will generate all details 

regarding the event automatically including the events source 

details (see part 5.1). 

 

N. 

Event 

Code 

001  Arming with remote control N.1 

Rc 

002  Arming with remote control N.2 

Rc 

003  Arming with remote control N.3 

Rc 

004  Arming with remote control N.4 

Rc 

005  Arming with remote control N.5 

Rc 

006  Arming with remote control N.6 

Rc 

007  Arming with remote control N.7 

Rc 

008  Arming with remote control N.8 

Rc 

009  Arming with master code 

Rc 

010  Arming with user code N.1 

Rc 

011  Arming with user code N.2 

Rc 

012  Arming with user code N.3 

Rc 

013  Arming with user code N.4 

Rc 

014  Arming with user code N.5 

Rc 

015  Arming with user code N.6 

Rc 

016  Arming with user code N.7 

Rc 

017  Arming with user code N.8 

Rc 

018  Arming with user code N.9 

Rc 

019  Arming with user code N.10 

Rc 

020  Arming with user code N.11 

Rc 

021  Arming with user code N.12 

Rc 

022  Arming with user code N.13 

Rc 

023  Arming with user code N.14 

Rc 

024  Partial arming 

Rc 

025  Quick arming without code 

Rc 

026  Disarming with remote control N.1 

Rc 

027  Disarming with remote control N.2 

Rc 

028  Disarming with remote control N.3 

Rc 

029  Disarming with remote control N.4 

rc 

030  Disarming with remote control N.5 

rc 

031  Disarming with remote control N.6 

rc 

032  Disarming with remote control N.7 

rc 

033  Disarming with remote control N.8 

rc 

034  Disarming with master code 

rc 

035  Disarming with user code N.1 

rc 

036  Disarming with user code N.2 

rc 

037  Disarming with user code N.3 

rc 

038  Disarming with user code N.4 

rc 

039  Disarming with user code N.5 

rc 

040  Disarming with user code N.6 

rc 

041  Disarming with user code N.7 

rc 

042  Disarming with user code N.8 

rc 

043  Disarming with user code N.9 

rc 

044  Disarming with user code N.10 

rc 

045  Disarming with user code N.11 

rc 

046  Disarming with user code N.12 

rc 

047  Disarming with user code N.13 

rc 

048  Disarming with user code N.14 

rc 

049  Entering of the programming mode 

Rc 

050  Exiting the programming mode 

Rc 

051  Communicator Reset 

Rc 

052  Initial AC powering 

Rc 

053  Alarm after initial AC powering 

Rc 

054  General battery trouble 

Rc 

055  General battery trouble end 

Rc 

056  Control panel battery trouble 

Rc 

057  Control panel battery trouble end 

Rc 

058  Zone alarm 1 

Rc 

059  Zone alarm 2 

rc 

060  Zone alarm 3 

rc 

061  Zone alarm 4 

rc 

062  Zone alarm 5 

rc 

063  Zone alarm 6 

rc 

064  Zone alarm 7 

rc 

065  Zone alarm 8 

rc 

066  Zone alarm 9 

rc 

067  Zone alarm 10 

rc 

068  Zone alarm 11 

rc 

069  Zone alarm 12 

rc 

070  Zone alarm 13 

rc 

071  Zone alarm 14 

rc 

072  Zone alarm 15 

rc 

073  Zone alarm 16 

rc 

074  Wrong access code alarm 

Rc 

075  Zone tamper 1 

Rc 

076  Zone tamper 2 

rc 

077  Zone tamper 3 

rc 

078  Zone tamper 4 

rc 

079  Zone tamper 5 

rc 

080  Zone tamper 6 

rc 

081  Zone tamper 7 

rc 

082  Zone tamper 8 

rc 

083  Zone tamper 9 

rc 

084  Zone tamper 10 

rc 

085  Zone tamper 11 

rc 

086  Zone tamper 12 

rc 

087  Zone tamper 13 

Rc 

088  Zone tamper 14 

Rc 

089  Zone tamper 15 

Rc 

090  Zone tamper 16 

Rc 

091  Keypad tamper 

Rc 

092  Control panel tamper 

Rc 

093  Siren tamper 

Rc 

094  Zone fault 1 

Rc 

095  Zone fault 2 

Rc 

096  Zone fault 3 

Rc 

097  Zone fault 4 

Rc 

098  Zone fault 5 

Rc 

099  Zone fault 6 

Rc 

100  Zone fault 7 

Rc 

101  Zone fault 8 

Rc 

102  Zone fault 9 

Rc 

103  Zone fault 10 

Rc 

104  Zone fault 11 

Rc 

105  Zone fault 12 

Rc 

106  Zone fault 13 

Rc 

107  Zone fault 14 

Rc 

108  Zone fault 15 

Rc 

109  Zone fault 16 

Rc 

110  Keypad fault 

Rc 

111  Control panel fault 

Rc 

112  Siren fault 

Rc 

113  Zone alarm end 1 

Rc 

114  Zone alarm end 2 

Rc 

115  Zone alarm end 3 

Rc 

116  Zone alarm end 4 

Rc 

117  Zone alarm end 5 

Rc 

118  Zone alarm end 6 

Rc 

119  Zone alarm end 7 

Rc 

120  Zone alarm end 8 

Rc 

121  Zone alarm end 9 

Rc 

122  Zone alarm end 10 

Rc 

123  Zone alarm end 11 

Rc 

124  Zone alarm end 12 

Rc 

125  Zone alarm end 13 

Rc 

126  Zone alarm end 14 

Rc 

127  Zone alarm end 15 

Rc 

128  Zone alarm end 16 

Rc 

129  Zone tamper end 1 

Rc 

130  Zone tamper end 2 

Rc 

131  Zone tamper end 3 

Rc 

132  Zone tamper end 4 

Rc 

133  Zone tamper end 5 

Rc 

134  Zone tamper end 6 

Rc 

135  Zone tamper end 7 

Rc 

136  Zone tamper end 8 

Rc 

137  Zone tamper end 9 

Rc 

138  Zone tamper end 10 

Rc 

139  Zone tamper end 11 

Rc 

140  Zone tamper end 12 

Rc 

141  Zone tamper end 13 

Rc 

142  Zone tamper end 14 

Rc 

143  Zone tamper end 15 

Rc 

144  Zone tamper end 16 

Rc 

145  Keypad tamper end 

Rc 

146  Control panel tamper end 

Rc 

147  Siren tamper end 

Rc 

148  Zone fault end 1 

Rc 

149  Zone fault end 2 

Rc 

150  Zone fault end 3 

Rc 

151  Zone fault end 4 

Rc 

152  Zone fault end 5 

Rc 

153  Zone fault end 6 

Rc 

154  Zone fault end 7 

Rc 

155  Zone fault end 8 

Rc 

156  Zone fault end 9 

Rc 

157  Zone fault end 10 

Rc 

158  Zone fault end 11 

rc 

159  Zone fault end 12 

rc 

160  Zone fault end 13 

rc 

161  Zone fault end 14 

rc 

162  Zone fault end 15 

rc 

163  Zone fault end 16 

rc 

164  Keypad fault end 

rc 

165  Control panel fault end 

rc 

166  Siren fault end 

rc 

167  Telephone line trouble 

Rc 

168  Telephone line trouble end 

Rc 

169  Control panel failure 

Rc 

170  End of control panel failure 

Rc 

171  Periodic test (24 hr. from last com.) 

Rc 

172  AC failure (in 30 min. after failure) 

Rc 

173  AC failure end  

Rc 

174  RF jamming 

Rc 

175  Wrong code alarm end 

Rc 

176  RF jamming end 

Rc 

177  Panic alarm  from remote control N.1 

Rc 

178  Panic alarm from remote control N.2 

rc 

179  Panic alarm from remote control N.3 

rc 

180  Panic alarm from remote control N.4 

rc 

181  Panic alarm from remote control N.5 

rc 

182  Panic alarm from remote control N.6 

rc 

183  Panic alarm from remote control N.7 

rc 

184  Panic alarm from remote control N.8 

rc 

185  Master code panic alarm 

rc 

186  User code panic alarm 

rc 

187  Panic alarm  end from rem. contr. 1  

Rc 

188  Panic alarm end from rem. control N.2  rc 

189  Panic alarm end from rem. control N.3  rc 

190  Panic alarm end from rem. control N.4  rc 

191  Panic alarm end from rem. control N.5  rc 

192  Panic alarm end from rem. control N.6  rc 

193  Panic alarm end from rem. control N.7  rc 

194  Panic alarm end from rem. control N.8  rc 

195  Master code panic alarm end 

rc 

196  User code panic alarm end 

rc 

197  Subsystem panic alarm 

Rc 

198  Subsystem panic alarm end 

Rc 

Содержание JA-65X

Страница 1: ...will disengage all other devices hooked up to the phone line It will then one by one call all programmed numbers and play the user recorded message which corresponds to the event If the dialer makes...

Страница 2: ...g method setting is also valid for Central monitoring station communications Factory default tone dialing 2 6 Telephone line checking sequence 9 9 x If this function is enabled the dialer will check r...

Страница 3: ...s the connection is established All events are reported to the Monitoring Station in the same order as they happened Once communication has started it can not be interrupted unless the control panel i...

Страница 4: ...tting sequence 04 If a dialer is triggered it attempts to make a connection alternating between the primary and the backup telephone number If it is not possible to make a connection after 8 attempts...

Страница 5: ...rc 061 Zone alarm 4 rc 062 Zone alarm 5 rc 063 Zone alarm 6 rc 064 Zone alarm 7 rc 065 Zone alarm 8 rc 066 Zone alarm 9 rc 067 Zone alarm 10 rc 068 Zone alarm 11 rc 069 Zone alarm 12 rc 070 Zone alar...

Страница 6: ...own fuse in control panel or other general failure 4 4 4 4 4 4 052 3 300 Control panel powering 4 148 3 300 No failure in the system 4 4 4 4 4 4 172 1 301 AC failure 4 173 3 301 AC switched on 4 054 1...

Страница 7: ...e programmed in the control panel 8 digits optional bypassing of answering machine if this option was programmed in the control panel if the connection can not be established try to enter space after...

Отзывы: