background image

 

The JA-62GSM communicator for GSM 

9 / 11 

MLD52902 

 

 

11. Summary of all communicator texts for SMS messages and instructions 

 

factory default text: 

factory default text: 

factory default text: 

Report from your alarm: 

300 

Master code 

510 

Alarm cancelled by user 

Wired detector #1 

301 

Code #1 

511 

Setting 

Wired detector #2 

302 

Code #2 

512 

Unsetting 

Wired detector #3 

303 

Code #3 

514 

Codeless setting 

Wired detector #4 

304 

Code #4 

515 

External communication failure 

Wired detector #5 

305 

Code #5 

516 

External communication restored 

Wired detector #6 

306 

Code #6 

517 

Fault 

Wired detector #7 

307 

Code #7 

518 

Fault no longer present 

Wired detector #8 

308 

Code #8 

519 

Mains dropout over 30 minutes 

Wired detector #9 

309 

Code #9 

520 

Mains dropout 

10 

Wired detector #10 

310 

Code #10 

521 

Mains recovery 

11 

Wired detector #11 

311 

Code #11 

522 

Discharged battery 

12 

Wired detector #12 

312 

Code #12 

523 

System power OK 

13 

Wired detector #13 

313 

Code #13 

524 

Switching to Service Mode 

14 

Wired detector #14 

314 

Code #14 

525 

Leaving Service Mode 

15 

Wired detector #15 

400 

System status 

528 

Radio jamming present 

16 

Wired detector #16 

401 

Set 

529 

Internal communication failure 

17 

Wireless detector #1 

402 

Unset 

530 

Internal communication restored 

18 

Wireless detector #2 

403 

Exit delay 

531 

Communication test 

19 

Wireless detector #3 

404 

Entrance delay 

535 

Partial setting A 

20 

Wireless detector #4 

405 

Alarm 

536 

Partial setting B 

21 

Wireless detector #5 

406 

Service mode 

538 

Partial unsetting A 

22 

Wireless detector #6 

407 

Maintenance mode 

539 

Partial unsetting B 

23 

Wireless detector #7 

409 

Discharged battery 

540 

Communicator failure 

24 

Wireless detector #8 

410 

Tamper alarm 

541 

Communicator OK 

25 

Wireless detector #9 

411 

Alarm memory 

542 

Backup battery failure 

26 

Wireless detector #10 

412 

Fault 

543 

Backup battery OK 

27 

Wireless detector #11 

413 

Power failure 

545 

Credit low 

28 

Wireless detector #12 

414 

Unknown status 

546 

Power ON 

29 

Wireless detector #13 

415 

Time: 

549 

Master code change 

30 

Wireless detector #14 

416 

Last event: 

550 

Message delivered 

31 

Wireless detector #15 

417 

Credit unknown 

551 

Message not delivered 

32 

Wireless detector #16 

418 

Credit 

553 

PG ON 

33 

Controller #1 

420 

Error while processing command 

554 

PG OFF 

34 

Controller #2 

421 

Output turned ON 

601 

SET 

35 

Controller #3 

422 

Output turned OFF 

602 

UNSET 

36 

Controller #4 

423 

Partially set A 

603 

STATUS 

37 

Controller #5 

424 

Partially set B 

604 

MEMORY 

38 

Controller #6 

426 

Command processing OK 

609 

PGON 

39 

Controller #7 

501 

Instant alarm 

610 

PGOFF 

40 

Controller #8 

502 

Delayed alarm 

611 

CREDIT 

41 

Wireless siren 

503 

Fire 

 

 

42 

Subsystem 

504 

Panic alarm 

 

 

201 

Control panel 

505 

Invalid code-entries exceeded  

 

 

202 

Service code 

506 

Alarm when power turned ON 

 

 

204 

Communicator 

507 

Tamper alarm 

 

 

205 

Keypad 

508 

End of tamper alarm 

 

 

206 

ARC code 

509 

End of alarm indication 

 

 

tab. 6 table of factory-default SMS report and instruction texts 

 

Notes:  

 

The communicator always automatically puts numbers from 01 to 42 in front of Device names 

 

Texts 

0 to 554

 are used to create SMS 

event reports

 

 

Texts 

601 to 611

 are SMS instructions (to control the system remotely by SMS) 

 

Texts are set by ComLink software  

 

Other texts with diacritics, if required, can be loaded from a file and save to the communicator 

Содержание JA-62GSM

Страница 1: ...or directional GSM antenna see 6 2 GSM signal strength measuring 8 If the GSM signal strength is sufficient test the communicator functions system control via a mobile phone etc see the instructions...

Страница 2: ...ved in the communicator Entering F9 before the first digit will insert a for the international formatting of phone numbers SMS report text consists of the installation name event type name of the even...

Страница 3: ...e text string but a space is valid within the text string spaces outside the text string are ignored Notes A single SMS TXT instruction can modify multiple texts limited only by the maximum length of...

Страница 4: ...or this activity can be requested automatically with a preset cycle and if it finds out that the remaining credit is lower than the preset value an information SMS is sent The function is set by send...

Страница 5: ...SIM card requires them must be programmed by sending the following SMS instruction to the communicator code_GPRS_x x_y y_z z where Code valid service system code e g 0000 _ space x x SIM card APN y y...

Страница 6: ...tocol allows very frequent checking of ARC communication even every 5 minutes in practice When 00 00 is set a communication check is not performed Factory default setting 23 59 hours mins 7 7 Enable A...

Страница 7: ...grammed repeat period see 7 6 If an alarm is cancelled by a user while it is being reported any unsent SMSes and unperformed call reports are cancelled but the ARC still gets a complete set of reports...

Страница 8: ...7 other event 24 21 Receiver jamming 5 fault 30 22 Setting Two section system Armed system 31 23 Unsetting Two section system Disarmed system 30 24 Setting zone A Armed system 31 25 Setting zone B Ar...

Страница 9: ...mode 539 Partial unsetting B 23 Wireless detector 7 409 Discharged battery 540 Communicator failure 24 Wireless detector 8 410 Tamper alarm 541 Communicator OK 25 Wireless detector 9 411 Alarm memory...

Страница 10: ...o 4 codes key fobs and master code setting unsetting enabled Forwarding of incoming SMS messages 801 x x 0 no x 1 if the incoming text is not an SMS instruction it will be forwarded to the first progr...

Страница 11: ...ording to the 07 p hhmm setting x 1 once a day at the time set by entering 07 p hhmm With a period after the last report X 0 ARC communication checking period 07 p hhmm p 1 ARC1 p 2 ARC2 hhmm hours mi...

Отзывы: