jablotron JA-60WEB Скачать руководство пользователя страница 3

JA-60WEB communicator 

-3 - 

MHO51103 

3.4 

Gateway IP address setting 

If DHCP is disabled, set the gateway IP address by sequence: 

 

93 xxx xxx xxx xxx  

 

where:

  xxx xxx xxx xxx  is the IP address 

 

Example:

 to set Gateway IP address 192.168.33.1 enter 93 192 168 033 001 

 

Factory default setting: Gateway IP address 192.168.1.1 

3.5 

Reset to default setting 

Entering 

96060

 will cause a return to the factory default settings, see 6 (the IP address and all unsent 

data will be erased). 

 

 

4  Web server remote access 

 

All parameters of the JA-60WEB communicator can be set via an internet browser. Full support is 

possible using MS Internet Explorer version 6 or higher. Setting can be done locally as well as from an 
outside network (if it is enabled – please consult the network provider / supervisor). 

4.1 

Access to the web server 

After setting has been done according to section 3 , enter the IP address of the communicator into 

your web browser (for example: http://192.168.1.23), the login dialog will appear.  
Factory default setting: 

Name:

 jablotron  

Password:

 jablotron 

Note:

  

The name and password can be customized (see 4.1.3) 
By clicking on the reset button which can be found on the most pages, you will reset the 
settings to their original values. 

 

4.1.1 Panel 

 

In the panel page the user can: 

ƒ

 

Monitor

 the control panel 

ƒ

 Operate 

Hot keys

 for controlling the control panel quickly 

ƒ

 

Enter programming or operating sequences in the 

Sequence input

 field 

ƒ

 

See the status and operate the outputs (AUX1-AUX3) and see the status of the input (INP)  

 

4.1.2 Events 

 

ƒ

 

To see the 127 latest events 

 

4.1.3 Communicator 

 

In the communicator page the user can: 

ƒ

 

Configure the network settings such as 

DHCP

IP

 

address

Netmask

 and 

gateway

 

ƒ

 Set 

the 

Idle time for auto logoff

, and 

HTTP port

 

ƒ

 Set 

the 

Function of the input

 (

off 

 - the status of the input will be only shown in the Panel 

Page, 

tamper 

– when connected to GND, the control panel will trigger the tamper alarm) 

ƒ

 Customize 

Login

 

Name

 and 

Password

 

 

4.1.4 Control 

panel 

 

This page is accessible only when the control panel is in programming mode (P). It enables full 
setting of the control panel. A detailed description of the parameters can be found in the control 
panel manual.  

Отзывы: