JA-60WEB communicator
-3 -
MHO51103
3.4
Gateway IP address setting
If DHCP is disabled, set the gateway IP address by sequence:
93 xxx xxx xxx xxx
where:
xxx xxx xxx xxx is the IP address
Example:
to set Gateway IP address 192.168.33.1 enter 93 192 168 033 001
Factory default setting: Gateway IP address 192.168.1.1
3.5
Reset to default setting
Entering
96060
will cause a return to the factory default settings, see 6 (the IP address and all unsent
data will be erased).
4 Web server remote access
All parameters of the JA-60WEB communicator can be set via an internet browser. Full support is
possible using MS Internet Explorer version 6 or higher. Setting can be done locally as well as from an
outside network (if it is enabled – please consult the network provider / supervisor).
4.1
Access to the web server
After setting has been done according to section 3 , enter the IP address of the communicator into
your web browser (for example: http://192.168.1.23), the login dialog will appear.
Factory default setting:
Name:
jablotron
Password:
jablotron
Note:
The name and password can be customized (see 4.1.3)
By clicking on the reset button which can be found on the most pages, you will reset the
settings to their original values.
4.1.1 Panel
In the panel page the user can:
Monitor
the control panel
Operate
Hot keys
for controlling the control panel quickly
Enter programming or operating sequences in the
Sequence input
field
See the status and operate the outputs (AUX1-AUX3) and see the status of the input (INP)
4.1.2 Events
To see the 127 latest events
4.1.3 Communicator
In the communicator page the user can:
Configure the network settings such as
DHCP
,
IP
address
,
Netmask
and
gateway
Set
the
Idle time for auto logoff
, and
HTTP port
Set
the
Function of the input
(
off
- the status of the input will be only shown in the Panel
Page,
tamper
– when connected to GND, the control panel will trigger the tamper alarm)
Customize
Login
Name
and
Password
4.1.4 Control
panel
This page is accessible only when the control panel is in programming mode (P). It enables full
setting of the control panel. A detailed description of the parameters can be found in the control
panel manual.