The JA-60WEB Communicator
Installation manual
The JA-60WEB communicator is designed for JA-63 and JA-65 alarm control panels. The dialer is
used for communication with a central monitoring station via an Ethernet network / the internet.
This
installation manual is intended for JA-60WEB version
HO61303
The WEB module, when installed in the alarm control panel, enables:
•
Data transfer in CID-IP format to one or two Cen ral Monitoring Stations (CMS),
t
•
Programming of the communicator via the web,
•
Remote control of appliances via a web page – 3 outputs and 1 input
1 Installation of the communicator
The JA-60WEB communicator can be installed in the telephone communicator position in a JA-63 or
JA-65 control panel (either a LAN communicator or a telephone line communicator module can be
sed in a control panel – it is not possible to install both simultaneously).
u
a)
Disconnect the control panel power supply
(both AC and backup battery). If the control
panel has been previously used before this installation, enter programming mode before
disconnecting the power supply.
b)
Attach the dialer to the control panel case and connect it to the control panel main board using
the RJ cable provided.
c)
Connect cables to the input (INP) and/or output (AUX) terminals, if you want to use them.
d)
Reconnect the control panel power supply
(backup battery and AC). The system will display
a “
P”
, (programming mode).
e)
When the communicator is powered up for the first time it is necessary to set the
Ethernet network parameters using the control panel keypad (see Local network
configuration)
f)
Connect the Ethernet cable (10/100 Mbps). If the communicator is working properly, LED 2 is lit
and LED1 flashes.
g)
Programming the communicator and the control panel is possible via web page (by accessing
the communicator IP address). It is also possible to connect the communicator directly to the
PC via a network cable with crossed connections (cross cable).
h) Central monitoring station communication shall be set according to data given by the CMS.