The JA-60V wireless outdoor PIR detector 

 

The JA-60V wireless outdoor PIR detector 

2 / 2 

MEB52102 

   You can restrict the detection angle by adhesive masking strips 

supplied with the package. This way you can eliminate problematic 

parts of the detection area. The strips are to be stuck on the relevant 

lens segment from the inner side.

 

The PIR detection sensitivity can be configured by a 3-pole switch 

located under the upper sensor. The letters correspond to sensitivity levels 

as follows:  

 

L

  low – applicable to bad conditions 

M

  middle  

H

  high  

 

Other parameters can be configured using a DIP switch:  

 

 

 

NORM

                                          TEST

 

120s                  

5s 

 

     5 s 

… šetřící režim

 

N.C.                                                  

N.O. 

LED OFF       

LED ON 

 

          on

 

Antimasking OFF 

Antimasking ON 

 

 

Factory settings highlighted by bold letters. 

 

 

 

 

The LED serves for PIR detector testing – checking the coverage. The 

detector always sends information to the control panel. For normal detector 

operation the LED should be turned off in order to save the battery. 

The power save mode can be set up by DIP switch no. 2, select 

5 s / 120 s. 

Testing (coverage test) 

 

By DIP switch no. 1, enter test mode and by DIP switch no. 4 turn on the 

LED indication. Close the detector.   Test the detection range of the 

protected area and immunity out of the protected area.  

Bear in mind the potential changing of detecting distance influenced by 

the environment.  

Each movement is indicated by LED and it sends the information to the 

control panel.  

We recommend turning off the indication LED when the testing procedure 

is finished. And set up the power save mode to 120s to get a longer battery 

lifetime. 

Normal operating mode 

The detector sends a radio signal about activation when it is triggered. In 

the  case of tampering with  the detector or tearing the detector off its 

position the detector sends a tamper signal. The communication checking 

is automatically performed at 15 minute intervals for the system to test that 

all its devices are present and ready for operation.  

Checking the status of and replacing 

batteries 

The detector checks its battery status automatically and if the batteries 

are running low it informs the system that they need replacing. The detector 

remains fully functional. The batteries should be changed as soon as 

possible (within 1 week). 

 

Before battery replacement 

the control panel has to be switched to 

service or maintenance mode (see installation manual of the control panel) 

and then it  is possible to open the cover of the detector. Always use 

alkaline AAA (2 x 1.5

 

V) batteries. When you close the cover the detector 

goes to the normal operating mode automatically. 

 

Note

:  If you insert a discharged batteries coincidently  then detectors 

won´t start working. 

 

Caution

:  Dispose of batteries safely depending on the type of the 

batteries and local regulation. Although this product does not contain any 

harmful materials we suggest you to return the product to the dealer or 

directly to the producer after usage. 

Troubleshooting 

Problem 

Problem cause 

Solution 

The detector 

makes false 

intrusion 

alarms 

Lower detection area is 

unnecessarily long. 

Set the detection area 

properly. 

The detector is exposed to 

direct/reflected light (sun 

light, car light etc.). 

Remove the reflector, 

mask the area exposed to 

the reflection of light or 

change the detector 

position. 

There is a moving object 

in the area (laundry on the 

clothes-line, plants etc.). 

Remove the moving 

object or change the 

detector position. Or put 

the stickers on part of the 

lens to avoid detection in 

a problematical place. 

Occasionally 

no reaction 

to 

movement 

Lower detection area is 

unnecessarily long 

Set the detection area 

properly 

Sensitivity is set to low (L).  Change sensitivity to 

medium (M) or high (H). 

The detector is in battery- 

save mode 

While testing operation, 

set the battery-save timer 

to 5 seconds. 

Detector 

ignores any 

movements 

Low battery 

Replace the battery 

LED does not light 

Turn the LED switch ON 

LED indicator lights but 

there is no reaction in the 

control panel. 

The control panel is out of 

range, check the battery, 

try to reposition detector 

or control panel 

 

 

 

Fig. 6. Detector dimensions (mm) 

Technical specifications 

Power 

2 x alkaline batteries type AAA (1.5 V) 

Average battery lifetime  

approx. 1 year* 

  -power save mode 120 s 

Communication band 

433,92 MHz 

RF range – communication range 

up to 100 m (open area) 

Optex detector parameter 

Detection characteristics 

12 m / 90 °; 16 segments 

Recommended installation height 

0.8 – 1.2 m 

Object motion speed 

0.3 – 1.5 ms

-1

 

Battery saving timer 

adjustable 5 s or 120 s 

LED indication 

during a coverage test 

Operational environment according to EN 50131-1 

IV 

Security grade  

according to Optex 

Operating temperature range 

-20 °C to +60 °C 

Detector cover conformance 

IP55 

Max. relative humidity of the environment  

95 % 

Dimensions  

186 x 71.3 x 105.5 mm 

Weight 

500 g 

Can be operated according to                

ERC REC 70-03 

 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-60V

 

is in 

compliance with the essential requirements and other relevant provisions 

of Directive 1999/5/EC  and 2011/65/EU.  The original of the conformity 

assessment can be found at 

www.jablotron.com

  -  Technical Support 

section.

 

 

Note: Although this product does not contain any harmful materials 

we suggest you return the product to the dealer or directly to the 

producer after use. For more detailed information visit 

www.jablotron.com. 

 

 

 

 

 