The JA-60V wireless outdoor PIR detector
The JA-60V wireless outdoor PIR detector
2 / 2
MEB52102
You can restrict the detection angle by adhesive masking strips
supplied with the package. This way you can eliminate problematic
parts of the detection area. The strips are to be stuck on the relevant
lens segment from the inner side.
The PIR detection sensitivity can be configured by a 3-pole switch
located under the upper sensor. The letters correspond to sensitivity levels
as follows:
L
low – applicable to bad conditions
M
middle
H
high
Other parameters can be configured using a DIP switch:
NORM
TEST
120s
5s
5 s
… šetřící režim
N.C.
N.O.
LED OFF
LED ON
on
Antimasking OFF
Antimasking ON
Factory settings highlighted by bold letters.
The LED serves for PIR detector testing – checking the coverage. The
detector always sends information to the control panel. For normal detector
operation the LED should be turned off in order to save the battery.
The power save mode can be set up by DIP switch no. 2, select
5 s / 120 s.
Testing (coverage test)
By DIP switch no. 1, enter test mode and by DIP switch no. 4 turn on the
LED indication. Close the detector. Test the detection range of the
protected area and immunity out of the protected area.
Bear in mind the potential changing of detecting distance influenced by
the environment.
Each movement is indicated by LED and it sends the information to the
control panel.
We recommend turning off the indication LED when the testing procedure
is finished. And set up the power save mode to 120s to get a longer battery
lifetime.
Normal operating mode
The detector sends a radio signal about activation when it is triggered. In
the case of tampering with the detector or tearing the detector off its
position the detector sends a tamper signal. The communication checking
is automatically performed at 15 minute intervals for the system to test that
all its devices are present and ready for operation.
Checking the status of and replacing
batteries
The detector checks its battery status automatically and if the batteries
are running low it informs the system that they need replacing. The detector
remains fully functional. The batteries should be changed as soon as
possible (within 1 week).
Before battery replacement
the control panel has to be switched to
service or maintenance mode (see installation manual of the control panel)
and then it is possible to open the cover of the detector. Always use
alkaline AAA (2 x 1.5
V) batteries. When you close the cover the detector
goes to the normal operating mode automatically.
Note
: If you insert a discharged batteries coincidently then detectors
won´t start working.
Caution
: Dispose of batteries safely depending on the type of the
batteries and local regulation. Although this product does not contain any
harmful materials we suggest you to return the product to the dealer or
directly to the producer after usage.
Troubleshooting
Problem
Problem cause
Solution
The detector
makes false
intrusion
alarms
Lower detection area is
unnecessarily long.
Set the detection area
properly.
The detector is exposed to
direct/reflected light (sun
light, car light etc.).
Remove the reflector,
mask the area exposed to
the reflection of light or
change the detector
position.
There is a moving object
in the area (laundry on the
clothes-line, plants etc.).
Remove the moving
object or change the
detector position. Or put
the stickers on part of the
lens to avoid detection in
a problematical place.
Occasionally
no reaction
to
movement
Lower detection area is
unnecessarily long
Set the detection area
properly
Sensitivity is set to low (L). Change sensitivity to
medium (M) or high (H).
The detector is in battery-
save mode
While testing operation,
set the battery-save timer
to 5 seconds.
Detector
ignores any
movements
Low battery
Replace the battery
LED does not light
Turn the LED switch ON
LED indicator lights but
there is no reaction in the
control panel.
The control panel is out of
range, check the battery,
try to reposition detector
or control panel
Fig. 6. Detector dimensions (mm)
Technical specifications
Power
2 x alkaline batteries type AAA (1.5 V)
Average battery lifetime
approx. 1 year*
-power save mode 120 s
Communication band
433,92 MHz
RF range – communication range
up to 100 m (open area)
Optex detector parameter
Detection characteristics
12 m / 90 °; 16 segments
Recommended installation height
0.8 – 1.2 m
Object motion speed
0.3 – 1.5 ms
-1
Battery saving timer
adjustable 5 s or 120 s
LED indication
during a coverage test
Operational environment according to EN 50131-1
IV
Security grade
according to Optex
Operating temperature range
-20 °C to +60 °C
Detector cover conformance
IP55
Max. relative humidity of the environment
95 %
Dimensions
186 x 71.3 x 105.5 mm
Weight
500 g
Can be operated according to
ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-60V
is in
compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC and 2011/65/EU. The original of the conformity
section.
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use. For more detailed information visit
www.jablotron.com.