JA-16A RB Wireless outdoor battery-powered siren

 

JA-16A RB Wireless outdoor battery-powered siren 

2 / 2 

MNM55101 

Enabling any of these mentioned options can 

cause a reduced battery lifetime  depending 

on the frequency of its use. That´s why 

we recommend fitting the BAT-100A second 

battery. 

Other acoustic indication from sections:

 selection of the sections  

for which sounds mentioned below will be produced. Default setting  

is ‘All sections. 

Higher volume:

  YES / NO*  -  affects only entrance / exit delay 

indication and sounds indicating PG output triggering. It doesn´t have 

any influence on the sound of an alarm. 

During section control:

  YES / NO*  –  if enabled, the siren chirps 

once after setting, twice after unsetting and three times when unsetting 

after an alarm. 

During warning:

  YES / NO*  -  When enabled the siren will beep 

three times to indicate: 

1) inability to set (a system status which prevents setting, such

as a fault or a triggered detector)

 

2) unsuccessful setting (an event occurs during exit delay, e.g.

a triggered detector)

3) unsetting with alarm memory (an alarm occurred)

 

Entry delay:

 YES / NO* if enabled, it indicates the entrance delay

for the whole entrance time – intermittent beeping. 

Exit delay when partially set:

 YES / NO* - if enabled, it indicates  

the entrance delay for the whole time when the system has been 

partially set – intermittent beeping. This option is available when 

Entry 

delay

 is enabled. 

Exit delay:

  YES / NO*  -  if enabled, it indicates the exit delay for  

the whole exit time when the system is fully set – intermittent beeping. 

Upon loss communication

: YES / NO* - When enabled, the siren 

sounds in case of loss communication with the control panel longer 

than (110 min). The length of sounding depends on ‘Maximum siren 

time’ – where the option ‘During an alarm’ signifies 20 minutes.  

Optical indication: 

Flashes every 60 s:

  YES / NO*  -  It sets to one siren flash per 

minute. It can be used as a warning that the building is protected  

by an alarm system. 

During warning: 

YES/NO* - if enabled, the siren indicates by triple 

flashing: 

1) inability to set (a system status which prevents setting, such

as a fault or a triggered detector) 

2) unsuccessful setting (an event occurs during the exit time, e.g. 

a triggered detector)

3) unsetting with alarm memory (an alarm occurred)

When controlled by a section:

  YES / NO*  –  it sets a siren to 

optically indicate setting and unsetting of (a) section(s). It blinks once 

when set and it blinks twice when unset and when unset after an alarm 

then three blinks.  

After alarm expiration: 

During alarms*/ 1/ 3/ 5/ 30/ 60 min  

of flashes after an alarm. This option can set the length of siren 

flashing for only the alarm time or extended for by a pre-set interval. 

Extended flashing can be terminated by new system setting or 

cancellation of alarm indication in the system (with a keypad). 

Periodical communication:

  1 s  / 8 s  –  This parameter can set  

the maximum  postponed reaction of the siren to an alarm, 

supplementary indication or Signalling PG. 

 

Notes: 

PG output activation sometimes might not be indicated when

periodical communication is set to 8 s and a PG output is

switched ON for a shorter time than 8 s. 

If the end customer wants any of the supplementary indications

mentioned above, we recommend setting  the ‘Periodical

communication’ to 1 s in order to have a faster response time

when section or PG state changes.

When periodical communication is set to just 1 s it can reduce

the typical battery lifetime by half. 

Signalling PG tab: 

The siren can indicate the activity of selected PG outputs with its 

beeps. 

Slow beeping

 - 1 per second (for the whole period when the PG  

is active) 

Quick beeping

 - 2 per second (for the whole period when the PG  

is active) 

1xOn/2xOff

 - 1 chirp when the PG is activated, 2 chirps when the 

PG is deactivated  

20 seconds of beeping

  –  a long 20 s  beep when the PG is 

activated 

Settings according to security grade 2 

To set the siren to comply with security grade 2 use N-Link SW, 

the ‘Parameters’ tab and the option ‘System profiles’ set to 

‘EN50131-1, gr.2’. Device will be configured according to required 

properties. 

Sound priorities 

The siren sound has the highest priority, the  control chirps have  

a lower priority and the PG output activity indication has the lowest 

priority (PG1 has a higher priority than PG2 etc). A chirp with a higher 

priority always terminates chirping with a lower priority. 

External antenna use 

To improve  the communication quality between the control panel  

and the outdoor siren you can connect an external antenna (AN-868).  

Plug the antenna into the connector (15) on the PCB. Detection  

of a connected antenna is performed only when the cover is open 

(active tamper). If the siren during closing the cover detects the 

external antenna, it is automatically used for radio communication.  

If the antenna is shorted out or cut off, it automatically switches to the 

internal antenna and a tamper alarm is sent. When the siren cover is 

closed with no external antenna, the internal antenna is used for radio 

communication. 

Battery replacement 

The product checks the battery status automatically. When 

a battery fault is triggered, the system informs its user (or service 

technician). The siren remains fully functional, but we strongly 

recommend  to replace the battery is replaced within 2 weeks. 

Don´t charge the battery at all. Use the BAT-100A type only. If two 

batteries are used, always replace both batteries at once. The 

battery can be changed in control panel service mode by a service 

technician. When replacing is finished, test the siren’s functioning. 

Take the used battery to an official collection point, don´t dispose 

in the general trash. 

Technical specifications 

The JA-16A RB parts (lithium battery, front cover and base) are 

supplied individually.  
Power 

Lithium battery 3.6 V/13 Ah type BAT-100A 

(up to 2 batteries can be used) 

Please note: battery is not included 

Current consumption (nominal/maximal) 

0.3 mA/1000mA 

Battery low voltage 

 2.8 V 

Typical battery lifetime 

approx. 5 years (for basic settings) 

Communication frequency 

 868.1 MHz, protocol JA-10 

Communication range 

approx. 300 m (open area) 

Antenna 

internal, external can be used, type AN-868 

Activation lost integrity 

acoustic tamper alarm (110 min) 

Piezo electric siren   

100 dB/m 

Dimensions (cover included) 

200 x 300 x 70 mm 

Weight 

434 g 

Classification 

security grade 2/environmental class IV 

- according to

EN 50131-1, EN 50131-4, EN 50131-5-3 

- environment

general outdoor 

- operational temperature range

-20 °C to +60 °C

- power supply

type W 

- operational humidity

75%  (95% 30 days) RH, non-condensing 

- certification body 

Trezor Test s.r.o. (no. 3025) 

Security grade

IP44 

Also complies with

ETSI EN 300 220-2, EN 50130-4, 

EN 55032, EN 50581,EN 62368-1 

Can be operated to 

ERC REC 70-03

 

 

JABLOTRON ALARMS a.s. hereby declares that the  

JA-16A RB is in a compliance with the relevant Union 

harmonisation legislation: Directives No: 2014/53/EU, 

2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the 

conformity assessment can be found at www.jablotron.com 

- Technical Support section. 

Note:

  Although this product does not contain any harmful 

materials we suggest you return the product to the dealer or 

directly  to the producer after use. For more detailed 

information visi

www.jablotron.com