JA-160PC (90) PIR motion BUS detector with a 90° verification camera

JA-160PC (90) PIR motion BUS detector with a 90° verification camera

1 / 3

MMQ53102

This device is a wireless component of the 

JABLOTRON JA-100 

system. It serves for the detection of human movement in building 
interiors and visual alarm confirmation. The camera takes colour photos 
with a resolution of up to 640x480 pixels.  Photos are taken following 
detected movement, which ensures that the cause of the alarm 
is always recorded. The camera is equipped with a visible flash for 
taking photos in the dark. The images are saved in the internal memory 
of the detector and then they are forwarded to the control panel 
via radio signal and from the control panel they can be sent 
to MyJABLOTRON, ARC and users. The detector can also take a photo 
by request. The detector should be installed by a trained technician with 
a valid certificate issued by an authorised distributor.

Installation

The detector can be installed on 

the wall or in the corner of a room. There 
should be no objects which quickly 
change temperature (e.g. heating 
appliances) or which move (e.g. curtains 
hanging above a radiator, robotic vacuum 
cleaners) or pets in the detector’s field 
of sight. It is not recommended installing
the detector opposite windows 
or in places with intense air circulation 
(close to ventilators, heat sources, 
air conditioning outlets, unsealed doors, 
etc.). There should be no obstacles 
in front of the detector which might 
obstruct its view of the protected area.

Figure: 1 – flash for illumination; 2 – camera lens; 

3 – PIR detector lens; 4 – cover tab;

Avoid installation too close to a ceiling. 
Using flash may cause over-exposure 
of the scene due to reflections. 

1. Open the detector cover (by pushing the cover tab (4)).

Avoid touching the PIR sensor inside (15) – you could damage it. 

2. Take out the PCB – it is held by a tab (9).
3. The recommended installation height is 2.5 m above the floor.
4. Attach the plastic base to the wall using screws (vertically, 

with the cover tab facing downwards).

5. Re-insert the PCB and plug the connecting cable (6) into 

the connector on the PCB.

Figure: 5 – Camera module; 6 – connection cable; 7 – batteries; 8 – red LED 

indicator; 9 – PCB tab; 10 – yellow LED; 11 – yellow LED indicator of Micro 

SD card;  12 – Micro SD memory card; 13 – mini USB connector; 

14 – tamper contact; 15 – PIR sensor; 16 – production code.

6. Proceed according to the control panel installation manual. 

Basic procedure:
a. The control panel must contain already enrolled JA-11xR radio 

module.

b.

Go to the 

F-Link

software, select the required position 

in the 

Devices 

tab and launch the enrolment mode by clicking 

on the 

Enroll

option. 

c. Insert the batteries (mind the correct polarity). When the second 

battery has been inserted into the detector, an enrollment signal 
is transmitted to the control panel and the detector is enrolled 
to the selected position. This is followed by up to three minutes 
detector stabilization phase indicated by the illuminated red LED 
indicator. If discharged batteries have been inserted the red LED 
indicator flashes for 3 minutes.

d. If the detector is enrolled as the first PIR camera or the control 

panel is not connected to an external mass storage, F-Link 

shows a dialogue window with the question: “Enable image 
transfer to external storage?” We recommend enabling this 
option with the agreement of the customer and confirming this 
acceptance by recording it in the system service log with his 
signature. 

Note:

If the transmission is not enabled, images will be saved in the 

internal memory of the detector and the control panel only. Then 
it is impossible to send them to users’ cell phones and e-mails.

7. Close the detector cover and test its functionality. When 

the detector has been closed, it starts the 15 minute test mode 
during which it indicates and reports every movement. After that, 
the red LED will not indicate movement and the detector works
in the standard mode.

Notes:

-

When the control panel is in service mode, the detector indicates 
every movement with the red LED indicator. 

-

If you want to enroll the detector in the control panel after the battery 
has already been inserted, remove the battery first and then press 
and release the tamper contact (14) to discharge the rest of the 
energy and then enroll the detector.

-

The detector can be enrolled by entering the production code (16) 
in the F-Link software (or a bar code reader). Enter all digits located 
below the bar code (1400-00-0000-0001).

-

If you want to remove the detector from the system, erase it from its 
position in the control panel.

-

In order to comply with the EN 50131-2-4 norm, the cover tab (4) 
must be secured with the supplied screw.

Detector internal settings

Settings can be set by 

F-Link

software in the 

Devices

tab. Use the 

Internal settings

option on the detector’s position to open a dialog 

window where you can configure the settings (

*

default settings):

PIR immunity level:

Defines false alarm immunity. The 

*Standard

level 

combines basic immunity with a rapid reaction. The Increased level provides 
higher immunity but the detector reaction is slower.

LQ photo quality:

Standard*

quality uses optimized compression in order 

to achieve the fastest possible transfer to the ARC or to the end user 
in MyJABLOTRON. The goal is achieving alarm verification in the fastest 
time possible. If the quality is switched to 

Extended, 

the system will use 

lower image compression which will at least double the time necessary 
to transfer the image (depends on the conditions of the captured scene). 
Change the quality only if the LQ image does not have the quality required 
by the customer – it may depend on the captured space. It is not 
recommended when there are more verification detectors in the premises 
which may take images at the same time.

Taking photos during alarms:

No flash, *With flash

Flash intensity: 

Low, *Medium, High – if the captured scene is over-

exposed (e.g.in a small room), the intensity of the flash can be decreased. 
It can be increased for larger spaces.

Lithium battery operation: 

If the detector is tasked with frequent 

operation (e.g. frequently requested photos by MyJABLOTRON) and 
is configured to high flash intensity, we recommend the use of AA 1.5 V
lithium batteries. If you operate the detector from lithium batteries, 
this parameter must be enabled (it adjusts detection of low batteries).

PG output reaction:

You can select PG outputs, whose activation will 

trigger taking a picture (

* No

, camera does not react to PG). For further info 

see 

Installation recommendations, cautions

.

Taking a photo by PG activation:

No flash, *With flash

Taking photos during entrance delay:

*No flash, With flash

Send pre-alarm photos:

This option is not available when the 

Extended 

LQ photo quality is selected due to more than double size of the photo and 
therefore longer transmission time. When this parameter is enabled the 
detector will send photos even when the detector is configured with repeated 
or confirmed reaction and the alarm has not been confirmed. During every 
entrance delay, up to two photos can be taken when the detector is triggered 
even when the system has been unset properly.

This option will noticeably increase the volume of data transferred 

to MyJABLOTRON or external mass storage. If the system is unset (alarm is 
triggered), the images taken during the entrance delay will be sent 
automatically regardless this option

Test:

takes a test photo (LQ) with a flash and F-Link displays it. When the 

Detail

button is pressed, the F-Link software shows the picture in a 640x480 

px resolution. Photos are sent to the external mass storage (provided that 
transferring is enabled).

To set the JA-160PC (90) detector to comply 
with security grade 2 or other requirements use 
F-Link SW, Parameters tab and the option 
“System profiles”.

Camera and basic reactions

The process of how the camera takes pictures depends 

on the settings in the 

F-Link

software

– the 

Devices

tab. Choose a type 

of 

Reaction

on the detector’s position.

Отзывы: