background image

The JA-157P dual zone outdoor wireless motion detector - curtain 

The JA-157P dual-zone outdoor wireless motion detector - curtain 

MMY51701 

The  JA-157P  wireless  outdoor  detector  with  curtain  lens 

characteristics  is  designed  to  indicate  disturbances  outside  the 
building caused by human bodies. It is a dual zone outdoor detector 
by Optex with a 5°angular width detection zone which makes it very 
suitable  for  guarding  narrow  spaces  such  as  balconies,  French 
doors, terraces, etc. It is supplemented with a transmitter compatible 
with the JABLOTRON 100 system.  The device is equipped with dual-
beam  optics  with  a  high  immunity  against  false  alarms  and  the 
detection  of  small  animals

The  detector  has  an  anti-masking 

function 

– i.e. protection against shielding its view. The detector is also 

equipped  with  three  tamper  contacts.  One  on  the  detecting  part  and 
the  next  two  on  the  transmitter  part  with  both  of  them  immediately 
reporting  tampering  of  the  detector  or  removal  from  the  installation 
place. The detector should be installed by a trained technician with a 
valid certificate issued by an authorised distributor.

 

Detector position and installation rules 

When selecting  the  place  for  detector  installation,  please  keep  in 

mind following instructions: 

 

The detector has to be installed onto a vertical wall 

 

The  detector  has  to  be  installed  0.8 

–  1.2  m  above  the 

ground 

 

The  best  movement  detection  is  provided  when  the 
detection beams intersect  

 

No  other  moving  objects  (bushes,  trees,  high  grass,  etc.) 
should be situated in the field of sight of the detector. Avoid 
direct action by strong sources of light (sun reflections). 

Installation 

1. 

The  detector  consists  of  two 
parts:  the  detection  part  (1) 
and  the  transmission  part  (2). 
Their  mutual  position  can  be 
adjusted  according  to  the 
picture.  Punch  holes  for  wires 
in the plastic transmission part 
of  the  detector  depending  on 
which position for the parts you 
have selected (there are holes 
indicated on the plastic for this 
purpose).                         

 

                                                              Fig. 1 
                                                       

 

2

1

3

4

5

6

9

4

7

8

10

10

 

Fig. 2: Detector parts: 1 

– Transmitter plastic part, 2 – tamper contact 

for transmitter part, 3 

– transmitter part cover, 4 – sealing sponge,  

– rear detection part, 6 – detection part, 7 – pull-out sealing cover,  

8 -  detection part cover, 9 

– lenses, 10 – locking screw for  the 

detection and transmission part 

 

2. 

Unscrew  the  locking  screw  (10)  and  remove  the  detection  part 
cover (8). The position of the detection part is fixed with a toothed 
plastic lug (7) which should be moved upwards. Then remove the 
whole part with the electronics (6) by bending the upper part of the 
plastic and pulling the swivel part towards you. You will thus make 
the installation holes located under this part accessible. 

 

Warning : Do not touch the sensors during handling 

 

3.  Pull  the  bundle  of  cables  through  the  punched  hole  into  the 

transmission part from the detection part.  

4.  Attach  the  detection  and  transmission  part  to  the  wall  using  the 

supplied  screws  (mind  the  correct  orientation 

–  marked  with  an 

upward-facing arrow on the plastic).  

5.  Use supplied self-adhesive plastic posts to attach the transmission 

module to the bottom of the transmission part so that the function 
switch  is located at the top left corner. Place the PCB as  high as 
possible 

– the bottom screw which attaches the plastic base to the 

wall must be visible. You will thus avoid possible interference with 
the antenna resulting in  reduced detector range. The module has 
to be fixed with the antenna upwards. 

6.  Use  connectors  to  interconnect  the  wiring  between  the  detector 

parts (can´t be mixed up). 

7.  Reassemble the detector. 

Switching on and enrolling the detector into 

the system 

When  the  detector  has  been  mounted  at  the  chosen  place  its 

necessary to enroll it to the system according to following procedure: 

a.  There must be a JA-110R radio module installed in the system. 

b. 

Go  to  the 

F-link

  software,  select  the  required  position  in  the 

Device

s window and launch the enrollment mode by clicking on 

the 

Enroll

 option.

 

c.  Insert  the  batteries  (mind  the  correct  polarity).  The  enrollment 

signal  is  transmitted  when  the  battery  is  inserted  into  the 
detector and it is enrolled to the chosen position. 

Use  a  CR123A  3  V  lithium  battery  only.  The  system  reacts  to 

triggering the detector according to the settings in 

F-Link / Settings / 

Devices / Reaction.

 

 
 
 

 

N.C. 

N.O. 

 

 

Status (INP) 

Pulse (INP)

 

 

AUX = Fault 

AUX = masking

 

 

 

Not used                                    

                          

                                       

Factory settings highlighted by bold letters. 

 
 
 
 
 

Fig. 3: Radio transmitter: 1 

– terminals, 2 – option DIP switch (pre-set 

from factory 

– DIP switch description see the figure), 3 – external 

tamper connector, 4 

– battery holder, 5 – external antenna jumper, 

 6 

– external antenna connector 

 

If  needed  the  transmitter  can  be  equipped  with  an  AN-80  or  

AN-81  external  antenna  connected  to  the  connector  (6)  and 
disconnect the jumper (5).

 

Setting up the optical part of the detector 

A detection range of 5 m or 2 m can be set. The setting is done by 

turning  the  bottom  detector  lens  (closer  to  the  centre  of  the cover). 
The lens shape is designed so that its projecting part uncovers the 
detection distance which you have selected when it is inserted back 
into the plastic base (see Fig. 4). Do not turn the upper lens!  

 

 

 

 

 

 

 

 

 

 

Fig. 4: 5m and 2m characteristics 

Masking function 

The  detector  has  an  Antimasking  function 

–  protection  against 

shielding its view.  When the function is enabled the detector sends 
infra-red  pulses  and  detects  possible  shielding.  The  shielding  is 
indicated if the obstacles are less than 10 cm from the detector. 

When  the  battery  is  inserted  and  both  plastic  covers  closed  the 

detector analyses its view in front of it for 1 minute 

– self-calibration. 

1

2

3

4

O
N

Отзывы: