background image

JA-156J Wireless multifunctional panic button 

JA-156J Wireless multifunctional panic button 

2 / 3 

MOO51302 

d.  Close the device by  replacing the backplate  in its  place and 

secure it in position with  the use of a fixing  screw, which is 

included in the packaging.  

Important:

  Place the panic button into the mounting platform by 

placing it between the hinges (1) so that both latches are securely in 

place  (3)  Fig. 3.  Orientation of the panic button is dependent on 

whether the customer wishes to  utilize  direct  button  activation by 

hand or bypressing the entire surface of the device  so that the 

device may be operated by hand, knee or foot*.  

Notes:  

̶

 

The device may be enrolled onto the system by entering it’s 

serial  number into 

the

  F-Link program. The serial number is 

located on the rear side of the device (example: 1400-00-0000-

0001). 

̶

 

Should you wish to remove the device from the system, it can 

be removed from the appropriate position via 

F-Link

 

̶

 

The device may only be enrolled onto a single system! 

 

Fig. 4: Method of opening the panic button: 1. Two indentations for opening 

the device with the use of a flat-head screwdriver.  

 

Fig. 5: Method of removing the light guide in order to replace it with a bank 

note holder. 

Device communication with the system 

The button  is equipped with bi-directional asynchronous  communication 

with the JA-11xR radio module which enables changing the internal settings 

with ease (just as it is with BUS detectors) while taking into account battery 

life time in normal operational mode. 

When the detector is enrolled to the control panel it works in the so-called 

accelerated 90-second mode until Service mode is terminated (up to 24 h). 

The  detector performs a check every 90 s  to monitor whether the control 

panel remains in Service mode, whether it should apply new settings. 

In the normal operational mode, the button communicates periodically with 

the control panel 1x every 20 minutes. Therefore it may take the button up to 

20 minutes to realize the control panel was switched to Service mode or to 

save  changes made in the internal  settings.  This period of time  can be 

shortened by triggering the detector which will switch it to the accelerated 90-

second mode immediately. 

Important: 

It is  not necessary to wait for 90 s (or 20 minutes) for the 

detector to confirm a request to save the changes made in the internal 

settings.  The control panel remembers such changes and transfers 

them to the detector the next time a periodical communication session 

occurs. 

Property settings 

Open the 

F-Link 

software,  go to the 

Devices 

tab. Click  on the 

Internal settings 

option at the device’s position to open  a dialogue 

window where you can set the following options: 

Monitor removal from holder:

 This parameter enables/disables the 

use of a tamper detector which reports the removal of the device from 

the mounting platform, this parameter is off by factory default. It must be 

noted that utilizing the device with bypassed tamper sensor results in 

non-conformity to Security Grade II classification.  

Optical signal:

  This parameter enables/disables the optical 

signalization of activation.  Signalization  is  red  and  yellow.  This 

parameter is on by factory default, it is also always on while the system 

is in service mode. 

Touch tones:

  This  parameter  enables/disables  short acoustic 

activation signalization. This parameter is on by factory default, it is also 

always on while the system is in service mode. 

Button:

 The button may be utilized to perform a pre-defined action: 

audible/silent panic, Fire alarm, Health troubles or reporting pre-defined 

text messages  (Reports  A,  B,  C,  D).  No function is pre-set by factory 

default.  

Banknote detection:

 If this function is to be utilized, it is necessary to 

to  remove the light guide covering the  B switch and to replace it with  

a bank note/document holder, which is included in the packaging. Once 

this function is turned on, it is necessary to choose one of the following 

functions:  audible/silent  panic,  Fire alarm,  Health troubles  or reporting 

pre-defined text messages (Reports A, B, C, D). We recommend setting 

the “Button“  option to “none“  if banknote detection is utilized, however 

operation of the A and B buttons is not mutually exclusive. 

Audible  panic:

  This parameter enables/disables acoustic 

signalization of an action being performed by the system, this function 

serves as a direct  system feedback. This parameter is on by factory 

default. 

Detecting the presence of a person:

  Enabling  this  parameter 

prevents the utilization of bank note/document presence detection and 

alarm button function, as these modes of operation are mutually 

exclusive. This option turns on a pre-set timer which must be configured 

according to the customer’s specification. Once service mode is exited, 

the timer does not start until the button is pressed. Once the pre-set time 

period expires, the device will send a pre-set report to the system. 

Press timer (h):

 Defines the length of the time period which may be 

set from  0,5  to 12  hours,  after which the button must be pressed. 

Pressing the button resets the timer. 

Length of warning (s): 

Defines the length of the time period during 

which the button both acoustically and visually signalizes that the button 

must be pressed as the press timer is running out. The time period may 

be set from 1 to 120 seconds. 

Report: 

This option allows for the defining the report that is sent to the 

system control panel unit once the press timer expires. The options are: 

None (suitable for when only button activation is utilized), audible/silent 

panic,  Fire alarm,  Health troubles  or reporting pre-defined text 

messages (Reports A, B, C, D). 

Blocking a function: 

The detecting the presence of a person function 

may be blocked  by selecting  and configuring  a PG, which may be 

controlled by calendar events, section setting or by a keypad segment. 

The PG should have the on/off function setting. This function is intended 

to be utilized in configurations where the presence of a person detection 

is required to be time limited (for example due to work hours, etc.). 

Note: 

Detecting the presence of a person

  significantly reduces 

battery lifetime, depending on the recurrence of the timer, this is further 

affected by optical and acoustic indication.  

Battery replacement 

The control panel automatically detects and reports low battery status. 

It is necessary to enter the system into the service mode before  

the battery replacement takes place (the button is equipped with  

a tamper sensor). The device may be opened as show on Fig. 4. Before 

placing new  batteries into the device, wait at least twenty  seconds or 

repeatedly press the activation button (in order to discharge any 

remaining energy within the device). In order to assure correct 

functionality of the device,  we  recommend the utilization of batteries 

supplied by the Jablotron distribution network or any other high-quality 

brand-name alkaline batteries.  

Important

Always replace both batteries, Do not discard the battery 

into the trash; dispose of it at a waste collection point. 