jablotron JA-153E Скачать руководство пользователя страница 2

The JA-153E Wireless access module with RFID and keypad 

Alternative power 

The keypad can be powered from an external 12V DC power 

supply via the PWR and GND terminals. The DE 06-12 power 

supply has the advantage of hidden installation. The keypad does 

not sleep if external power is used. It permanently communicates 

with the control panel and it indicates the system status according 

to the 

Devices / Internal settings.

.Leave the batteries inside the 

keypad. When the mains power is cut off, the keypad will work from 

the batteries. 

Connection of an external door detector 

The keypad has an input terminal for external door detector 

connection. The input (IN) reacts to disconnection from the 

common ground. The reaction of this input is always delayed, and 

is linked to the keypad address. The input has a status reaction. 

According to the settings, the keypad can be completely woken up 

by triggering the external detector. 

Caution: this type of waking up is good to use when the keypad is 

powered from the external power supply otherwise every activation 

tends to shorten battery lifetime. 

 

 

Battery replacement 

The system automatically reports a Low Batt from the keypad. 

Before you change the batteries, switch the system to service mode, 

otherwise a tamper alarm will be triggered. 

Unit modifications 

Note

If there is a request to modify the keypad hardware, always 

remove the batteries and disconnect the external power supply.  

If you need to change the segments (add or take out), release them by 

levering on both sides of the segment near the buttons. When you have 

finished, changing the amount of segments the new JA-192Es are not 

always immediately visible in the F -Link software. For synchronization, 

click on the 

Upload

 button.  

FW upgrade  

1.  Upgrades can only be done by a Service technician. 

2. 

F-Link

 software is necessary for upgrades. 

3.  Start the F-Link in Off-line mode and open the appropriate 

database  

4.  Open the keypad by pressing on the tabs (5). 

5.  Remove the batteries and possible external power supply. 

6. 

Connect the miniUSB cable to the USB port on the PC. 

(Caution: the miniUSB is not in the accessories of the keypad, 

control panel or any other device. You can use the cable from 

the JA-190T card reader. We strictly recommend connecting 

the USB straight to the PC, connection via a USB HUB can 

reduce the reliability. 

7.  Press and hold the backlit activation button (3). 

8.  When the button (3) is pressed, connect the miniUSB cable to 

the connector on the module (10). 

9.  Switching to the mode for upgrading firmware (according to the 

version of the keypad in about 5 esc.) indicated by the yellow 

LED flashing or by the backlit activation button flashing green 

and yellow (now you can release the button (3)). 

10. Then continue as if you are doing an upgrade via 

F-link

 

software: 

Control panel 

→ U

pgrade Firmware

 

→ choose the 

upgrade file pack (it is a part of the F-link installation pack, or it 

can be independently published for downloading, file type 

*.fwp) 

11. F-Link shows a window with a device listing, select the USB 

(typically at the first position). 

12. Then press 

OK 

and perform the upgrade for the selected 

device. 

13. Disconnect the miniUSB cable, reinsert the batteries and 

reassemble the keypad. 

14. Check the keypad via 

F-Link

Devices/Internal settings

According to the changes which have been done during the 

upgrade, previous settings might stay or settings could be 

erased to default. When a reset has been done you can reload 

the previous settings by the 

Import

 

button and restore them 

with no negative influence on the new firmware. 

15. When the FW upgrade has been done, the main menu could be 

expanded. In this case the new options are set to default. 

Check their settings and adjust according to user requirements. 

16. Perform a last check and try out the functions by some tests. 

 

 

17. 

 

 

Technical specifications 

Power 

2 x alkaline batteries AA (LR6) 1.5 V 2400 mAh

 

Typical life time 

1 - 2 year(s) according to the settings 

Communication band 

868.1 MHz, JABLOTRON protocol 

Communication range 

200 m (open area) 

Power input from external supply 

0.5 W 

RFID frequency 

125 kHz 

Dimensions 

102 x 75 x 33 mm 

Weight 

200 g 

Classification  

Grade II 

According to  

EN 50131-1, EN 50131-3, EN 50131-5-3 

Operational environment  

EN 50131-1 II. Indoor general 

Operating temperature range 

-10 to +40 °C 

Also complies with 

ETSI EN 300330, ETSI EN 300220 

 

EN 50130-4, EN 55022, EN 60950-1 

 

 

JABLOTRON ALARMS a.s. hereby declares that the 

JA-153E

 is 

in compliance with the essential requirements and other relevant 

provisions of Directive 1999/5/EC. The original of the conformity 

assessment can be found at 

www.jablotron.com

  -  Technical 

Support section

 

 

Note:

 Although this product does not contain any harmful materials 

we suggest you return the product to the dealer or directly to the 

producer after use. For more detailed information visit 

www.jablotron.com

.

 

 

 

 The JA-153E Wireless access module with RFID and keypad 

2 / 2 

MLU51704 

 