The JA-152SHM wireless shock or tilt detector with magnetic 

contact 

JA-152SHM 

1 / 2 

MLB55202 

The product is a wireless component of the 

JABLOTRON 

system.  

It is a combined shock or tilt detector with external input. It occupies two 

separate enrolment addresses in the control panel. The product can be 

installed by a trained technician with a valid certificate issued by an authorized 

distributor. 

The product is compatible with the JA-103K, JA-107K or above. 

 

Installation 

It is always necessary to have a look at  how the detector is used. 

We do not recommend installing the detector directly onto metal surface 

that can negatively affect wireless communication with a control panel. 

The detector responds to vibrations and shocks caused by the pad to 

which it is mounted when the shock mode is selected. The mechanical 

contact must be  sufficient for a good transmission of shocks to  

the detector. The detector should be placed in locations where stronger 

shocks are expected – i. e. further away from fixed edges of windows or 

door frames. 

When in a tilt mode, the detector reacts to a change in its position. – 

e. g. on a window casement.

There are two different types of permanent magnets in the package –

a standard magnet in a plastic housing (A) and a ring-shaped magnet (B) 

for use in places where there is not enough space for a standard magnet 

or for counter-sinking the magnet into a door or window’s inner frame. 

The detector activation distance threshold (only applicable to non-

ferromagnetic installation surfaces) is 26 / 17 mm for the Z axis. For other 

types of magnets, the detection threshold characteristic may vary.  

Figure: 1 – place for locking screw, 2 – cover tab, 3 – LED indication,  

4 – battery, 5 – serial number, 6 – terminals, 7 – cover tamper contact 

Axis 

Activation distance (mm) 

13 

27 

27 

Deactivation distance (mm) 

21 

20 

Table 1: distances for opening and closing on a non-magnetic base.

 

Axis 

Activation distance (mm) 

13 

28 

28 

Deactivation distance (mm) 

19 

21 

Table 2: distances for opening and closing on the magnetic base. 

1. Open the detector cover by pressing the cover tab (2).

2. Mount  the rear pad  onto the required place. If it´s needed, put

the cables through the rear plastic pad. The length of cables to

the detector should not exceed 3 m; choose the place of installation

accordingly.

3. Attach the selected magnet to the moving part of the door (window)

with screws. The lower edge of the standard magnet has to be at

the same height as the lower edge of the detector. It is recommended 

to attach the whorl-shaped magnet with a non-magnetic screw from

the package.

4. Connect the wires from external contact to the terminals, if they are

used.

5. Proceed according to the control panel installation manual.

Basic procedure:

a. In the  F-link software, select the required position in

the Devices window and launch the enrolment mode by

clicking on the Enrol option.

b. Insert the battery  (mind the correct polarity). The enrolment

signal is transmitted when the battery is inserted into

the detector. 

Note

 – the detector occupies 2 positions (each

input has its own position). Should the second position be

occupied, it will be automatically overwritten.

6. Close the detector cover.

7. In order to comply with norms, the front cover must be secured with

the supplied locking screw (1).

8. Configure the detector by following the 

Internal settings

 chapter in

this manual.

Notes:

 

The detector can also be enroled into the system by entering its

serial number (5) into the F-link software (1400-00-0000-0001).

You can find the sticker with serial number under a bar code,

located on the battery holder.

If only the first input is used, the second input can be deleted by

pressing “Delete” to release the position for another device.

By deleting the first input position, the module will be deleted

completely.

Detector communication in the system 

The detector uses bi-directional asynchronous communication which 

allows you to change the internal settings remotely and at the same times 

does not consume a lot of battery capacity. 

After enrolment to the system, the detector operates in an accelerated 

mode, until the service mode is exited (but no longer than 24 h). In this 

mode, the detector checks every 90s whether system is still in service 

mode or if new settings should be taken over. 

In service mode, the detector communicates once every 19 minutes or 

with each activation. Therefore, when switching from operational mode to 

service mode, it can take up to 19 minutes for the detector to recognize 

control panel status or internal settings change. This period can be 

reduced by activating the detector or its tamper sensor. 

Please note: 

It is not necessary to wait 90 s (or 19 min) until the detector confirms 

delivery of the new setting, when changes are applied. System 

remembers the requested change and forwards the new settings to 

the detector during the next period of regular communication. 

Internal settings 

The detector settings can be set in the 

Devices

  tab of the F-link 

software. Click on the 

Internal settings

 button at the detector’s position 

to open a dialogue window where you set 

(* indicates default settings):

 

Input 1 - 

Function:

 Shock* / Tilt / Disabled 

Shock: 

The device responds to environmental shock input.

 

Activation of shock:  

Turning on the detector option after the 1st shock will ignore any further 

shocks for 10 seconds. After this 10 s, there will be a 30 s interval in which 

the next possible jolt will be reported as an Input Activation. If no further 

shocks occur within these 30 s, the 1st shock will be ignored - no Input 

Activation will be reported in the system. By disabling the option, the 

detector sends an Input Activation to the system as soon as the 1st shock 

is detected. 

Sensitivity

:

 Detector sensitivity level. The detector ignores jolts/tilts that 

do not exceed the sensitivity setting.  Automatic shock sensitivity 

adjustment: how to adjust the sensitivity: 

To start the calibration from the peripheral, the system must be in 

Service mode, then Activate tamper contact (open the plastic cover) and 

within 5 seconds deactivate the tamper contact (close the plastic cover). 

This procedure will switch on calibration directly from the peripheral - 

indication as described below from point 3. When starting calibration from 

the detector, the Yellow LED will not be lit (it is only lit if the peripheral has 

an open internal setting in the F-Link). Calibration can be terminated by 

activating the tamper contact (open the plastic cover). 

1.

LED off = detector waiting for connection. To continue, activate 

the magnet (open and close the window/door)..

2.

Yellow LED illuminated = detector has established

a connection. Start calibration to continue.

3.

Glow yellow LED + regular double red LED = detector is ready 

to start calibration. Activate magnet to continue.