The JA-121T BUS RS-485 interface 

The JA-121T BUS RS-485 interface 

2 / 3 

MNN51110 

 

Model example: 

1*1234 SET 1 2

 (set sections 1 and 2) 

2*4321 PGOFF 5 6

 (turn off PG 5 and 6) 

 

When the syntax has been entered correctly and if the sections 

were not set before, the returned answer will be: 

STATE 1 ARMED 
STATE 2 ARMED 
OK 

According to this example it can be seen that the command has 

been done successfully so sections 1 and 2 have been set and  

the command was correct (OK). 

 

If at least one section of the defined range has already been 

previously set, then it sets the rest of the sections. When section  

1 is already set, the returned answer will be: 

STATE 2 ARMED 
OK 

 

If  an entered command  is found to be correct, but with invalid 

authorisation, the returned answer will be: 

ERROR: 3 NO_ACCESS 

 

If the system was not able to execute any of the commands  

(for example when all sections are already set) the returned answer 

will be: 

ERROR: 4 INVALID_VALUE 

 

To an incorrectly entered command, the returned answer will be: 

ERROR 

 

Basic statuses of the sections:

 STATE <section> <status> 

Example: 

STATE 1 READY

 

List of section statuses: 

READY

 

Normal mode

 

ARMED_PART

 

Partially set 

ARMED

 

Set 

MAINTENANCE

 

Maintenance 

SERVICE

 

Service 

BLOCKED

 

Blocked (blocking after an alarm) 

OFF

 

Section disabled 

Additional flags of the sections: 

<flag> <sections> ON/OFF 

Example: 

INTERNAL_WARNING 2 ON

 

List of section flags: 

INTERNAL_WARNING

  Internal siren active

 

EXTERNAL_WARNING

  External siren active 

FIRE_ALARM

 

Fire alarm 

INTRUDER_ALARM

 

Intruder alarm 

PANIC_ALARM

 

Panic alarm 

ENTRY

 

Entrance delay 

EXIT

 

Exit delay 

 

A status of individual devices is returned  after the PRFSTATE 

command or automatically every 10 seconds according to  the 

Passive mode

. A conversion of the numerical sequence from HEX 

form to BIN has to be performed. This numerical sequence consists 

of  14 characters for the JA-101K control panel,  32 characters for 

the JA-106K control panel and 60 characters for the JA-103K and 

the JA-107K control panels. 

Example: 

PRFSTATE 289600000800000800000A0000008000 

According to the figure 2 below we can see, after conversion to 

the BIN format, which devices are triggered. The active devices are 

no. 3, 5, 9, 10, 12, 15, 35, 59, 81, 83 and 119. 

 

Figure 2: Displayed layout conversion from HEX to BIN 

U1-A mode – function description  

(customer’s settings) 

The events are converted to the set U1-A mode code, it is visible 

as  another  ARC  –  concerning the radio communication module  

(F-Link  sets up a new way of communication). When no U1-A 

device is connected and no data packets are transferred between 

the  system BUS and the U1-A system, a communication error is 

triggered (fault of U1-A communicator). 

Setting the module properties 

The 

Internal settings

  option  at the module position in  

the 

Devices

  tab in the F-Link software opens a dialogue window 

where you can set the following options for each output: 

Device basic mode:

  Terminal / U1-A  –  for use with a smart 

home choose Terminal. 

TMP terminal:

 Enabled / Disabled / Inverted – factory default NC 

can be changed to NO. 

Motherboard button:

 Enrolling button / Tamper contact 

Period after which a fault is triggered [min]:

 When an external 

communication fault is triggered it generates a fault in  a pre-set 

time. 

Connection confirmed:

  Every 10 s / Disabled –  determines  if 

the communication with the RS-485 serial line is confirmed or not. 

Passive mode:

 In the passive mode the RS-485 serial line only 

receives the data, but sends them only on request  (by  relevant 

commands). 

 

The manufacturer only guarantees correct 

functioning of the module. However, they 

cannot guarantee the correct functioning  

of the connected device on the serial line. 