The JA-115P BUS ceiling PIR motion detector 

JA-115P BUS ceiling PIR motion detector 

MOM53100 

This  detector is a BUS  device of the JABLOTRON 100  series.  

It is intended to be used for movement detection in building interiors. 
The detector should be installed on a ceiling. Its guaranteed detection 
coverage is 360° with a radius of up to 5.5 metres when installed 3.5 metres 
above the floor. False alarm immunity is configurable at two levels. 

 

The detector has a pulse reaction, takes one position in the system and  
it should be installed by a trained technician with a valid certificate issued  
by an authorized distributor. 

Installation 

It is necessary to take into consideration that there should be no obstacles  

in the detector’s view which quickly change temperature (electrical heaters,  
gas appliances, etc.), which move (e.g. curtains hanging above a radiator,  
robotic vacuum cleaners); or any undesirable movement of house pets.  
Despite the detector being very resistant to false alarms, it is not recommended 
to install the detector opposite windows, floodlights or in places with over-
intense air circulation (close to ventilators, heat sources, air conditioning outlets, 
unsealed doors, etc.). There should  be no obstacles in front of the detector 
obscuring its view over the monitored area. 

Figure 1: 1 – release direction; 2 – fixing direction;  

3 – hole for a fixing screw; 4 – Indication LEDs 

1.

Turn the top part counter-clockwise (1) to open the detector.

2. 

Insert the BUS cable through an appropriate cut-out hole in the base 
and attach the detector base to a selected place on a ceiling. 

3.

Eject the removable part of the BUS terminal (8) from the base and 
connect to it the BUS wires according to the colour label and
description.

4.

When switched on, the  red LEDs will light up and stay on until
the end of detector stabilization (up to 1 minute). After that a yellow
LED will flash (to indicate the detector has not been enrolled  into 
the system).

5.

Follow the instructions stated in the control panel installation
manual. 

Basic procedure:

a.  Open the F-Link software, select an unused position in the 

Devices

 

tab and click on the 

Enroll  

button to enter the 

Enrollment mode

 

b.

Click  on  the option “

Scan/add new BUS devices

” and select

this detector from the offered list and double-click to confirm
selection. The yellow LED indicator goes off.

6.

Attach the detector back onto its base and fasten it by turning
it clockwise (2). The detector can only be attached at one position
marked by alignment arrows and the JABLOTRON logo (5) on both
parts.

7.

To comply with norms and their requirements, it is necessary
to attach the top part to the base (3) using a fixing screw included
in the packaging.

8.

Configure the detector by following the instructions in the 

Property

settings 

section.

Figure 2: 5 – alignment arrow / logo; 6 – production number;  

7 – tamper sensor; 8 – BUS connection terminal 

Notes: 

The detector can also be enrolled into the system by sending
an enrollment signal, which is done automatically when attaching
the detector onto its base – the tamper sensor triggers (7).

The detector can also be enrolled into the system by entering its
production code in the F-Link software. You can find the production
code on the sticker placed inside the detector (6). All numbers
under the bar code shall be entered (1400-00-0000-0001).

If you want to remove the device from the system, erase it from its
position in the F-Link software. 

Property settings 

Open the 

F-Link

 software, go to the 

Devices

 tab. Click on the 

Internal 

settings

  option at the siren’s position to open a dialogue window where 

you can set the following options: (

*

 indicates default settings). 

LED movement indication: Disables  /  Enables*

  movement indication 

with a red LED (4). Always indicates in Service mode. 

Immunity level:

 Determines the immunity to false alarms. The 

Standard* 

level combines basic immunity with a rapid reaction. The 

High 

level provides 

increased immunity, but the detector reaction is slower. 

Higher detection sensitivity when unset:

 

Enabled  /  Disabled*

  -  

It is possible to increase the movement detection sensitivity when unset,  
if  the detector is also  used for  home automation (e.g. switching the lights  
on with a PG output). 

Detection characteristics 

The detector is fitted with a 360° lens which covers the monitored 

area  with 3 main circular zones separated into 64 beams. The lens 
cannot be replaced by a different type.

 

The maximum recommended installation height is 3.5 m 

(installing the detector higher will lead to a lower sensitivity underneath 
the detector). 

Figure 3: The above diagrams apply only to the standard immunity level. 

When connecting the detector to the 
system BUS, always switch the power off. 