JABLOTRON
ALARMS
a.s.
Pod
Skalkou
4567/33
46601
Jablonec
n.
Nisou
Czech
Republic
www
.jablotron.com
||
|
JA-14K(R) Security System Control Panel
69 / 72
MNX22101
14 Supplementary information
14.1 Overview table of current consumption of BUS devices
Device
Consumption in
the backup mode
Consumption for
cable selection
Note
JA-10E
LCD keypad
30 mA
110 mA
JA-111R
Radio module for
wireless connection
25 mA
25 mA
JA-10A
Internal siren
5 mA
30 mA
during an alarm
JA-11A
External siren
5 mA
50 mA
in case of an AC supply
failure without battery charging,
otherwise 550 mA depending
on battery charge
14.2 Control panel currents overview
Control panel
Consumption in the backup mode Consumption in the AC power
supply mode (mA)
JA-14K (inactive LAN)
Control panel with no
supplementary comunicators
45 mA
50 mA
JA-14K (with LAN enabled)
Control panel with no
supplementary comunicators
75 mA
80 mA
JA-190X
PSTN communicator
15 mA
15 mA
JA-190Y
GSM communicator
25 mA
25 mA