10.7 Parameters tab
It is used to set parameters and selectable functions of the control panel.
Language, Activation
Language selection (language of pre-set texts and voice menu) + Activation
button (see 10 Setting the system through N-Link SW)
Date/Time
Internal calendar setting.
Standard time / Daylight
saving time*
Automatic switching of the winter and summer time can only be selected
for manual time adjustment. The change occurs on the last Sunday of March
or October, respectively at 1:00 UTC (i.e. e.g. 2:00 CET, or 3:00 CEST).
Time adjustment*
Internal time and date adjustment method:
Manually
Manual setting of the time and data using N-Link
From the GSM network
Time and date are taken from the GSM provider
with every logging in to the GSM network
From the Jablotron server
(LAN / GSM)
Time and date are adjusted automatically
according to communication server. Option does
nothing when the type of communication is set
to “Without remote programming” (factory
default setting)
Siren IW when partially set
Allows you to set an acoustic alarm with the IW system if the section is partially
set. Fire and 24 hours reactions never activate a siren in the case of an alarm,
regardless of how is this parameter set.
Sirens enabled*
Enables all BUS and wireless sirens of the system (designed for disabling
the acoustic alarm during system testing).
Administrator restricted
Service and ARC
It blocks independent access of service technicians and ARC to the system.
Note: In case of remote access of a technician to the system via N-Link
the administrator may get authorized using a keypad in the building. In the case
of a local connection of a technician to the control panel using a USB cable and
a supplementary GSM / PSTN communicator being connected the
administrator may get authorized remotely using the voice menu.
Service and ARC control
system*
This setting allows the service technician and ARC technician to control
the system for all the sections. If this parameter is disabled, the technician
is not authorized to control sections and will only be able to enter the Service
mode after unsetting of all the sections by the Administrator or a user.