4.8. Icing protection

The heat recovery system is technically as well as structurally ready for operation at temperatures below the freezing 

point without the need of preheating, down to the temperature of -19 °C. During operation, when the outdoor temperatu-

res remain below the freezing point, the drying cycle is activated as necessary – based on the operation logic evaluation. 

The interval between drying cycles is not fixed; it is activated approx. 1× every 3 days. In the period of extreme frosts, this 

interval may get reduced.

Thanks to this function, no other frost protection in the form of electric preheating is necessary (see page 7, 5. Operation 

modes).

4.9. Operation together with fireplaces

The heat recovery system is designed for operation together with a fireplace that is intended for passive buildings, has 

a sealed fireplace insert and its own air supply.

The system must not be operated together with an open fireplace or with any fireplace without its own air 

supply!

Use together with fireplaces is only possible if the relevant safety and fire regulations and standards are observed. This 

operation requires setting and using the Overpressure function (see page 8, 6. Functions of the heat recovery system).

5.  Operation modes 

The user can set several modes of the heat recovery unit that influence its current output. In the default state, the unit 

works in the Automatic Mode. The current mode of the unit can be changed in the Time Schedule or manually (control) The 

operation modes of the heat recovery unit are shown in Tab 3.

Off 

The unit is off, does not evaluate the connected peripherals, no temperature, humidity or CO

2

 

measurements are carried out. It communicates with the Jablotron cloud in longer time intervals 

(of several hours). The unit responds to the On command. The consumption in this mode is below 

the threshold of 1 W. If the air temperature at the outlet of the heat recovery system decreases 

below 0 °C, the Drying mode will be started and the unit can only be switched off after that. 

If the unit is switched on during Drying, this mode must be completed first and the unit can only 

be switched on after that.

Stand-by 

The heat recovery system is in the standby mode, but the air exchange is not active. Information 

from all the connected sensors is available, being continuously evaluated. Thanks to the connection 

to the Jablotron Cloud, the heat recovery unit can be activated and its settings can be changed any 

time. In the Stand-by mode the unit responds to the Boost function.

Constant Power 

This is a mode where the user selects the fan power level in the range of values 1 – 5. Depending 

on the temperature and humidity setpoint, the system controls the by-pass flap and connected 

peripherals. It controls turning of the heat exchanger flaps and the drying flap based on the 

actual temperature and humidity.

Automatic Mode 

Default mode of the heat recovery unit. This is a mode that uses information from the connected 

CO

2

 sensors and controls the fan power based on the current values. The ventilation power 

is adapted to the requirements for quality of the indoor environment. The unit remains in this 

mode until it is switched to the Time Schedule mode.

Time Schedule 

A mode where the user adjusts the fan power level in the range of values 1 (minimum) 

– 5 (maximum), Stand-by and Automatic Mode.

Drying 

A mode started automatically to remove moisture from the heat recovery unit. The drying takes 

3 hours and the flaps of the heat exchanger are further turned over in intervals determined 

by the dew point temperature. During this mode, the user comfort is not reduced; the air that 

is supplied to the indoor space is warmer than the air that is exhausted. If the Boost function 

is activated during drying, the forced exhaust time is limited to 2 min.

Too Low Outdoor

Temperature 

A mode started automatically when the outdoor temperature drops below -20 °C. Drying is 

carried out while the air exchange and ventilation are suspended.

Tab. 3 – Operation modes

Содержание Futura

Страница 1: ...Heat recovery unit...

Страница 2: ......

Страница 3: ...1 1 Wall mounted control 9 7 1 2 Optional accessories 10 7 1 2 1 Boost ventilation switch 10 7 1 2 2 CO2 sensor 10 7 2 Remote control 10 8 Guarantee 11 9 Disposal of the equipment 11 Appendices Append...

Страница 4: ...ully It will provide you with information about the principle of heat recovery structural design of the heat recovery system and its modes functions operation and simple maintenance Pay attention to a...

Страница 5: ...9 We do not recommend you to leave the heat recovery system off for prolonged periods even in the periods of absence of persons Always let the system run at the lowest ventilation level or in the Auto...

Страница 6: ...at provides a clear indication of the current status of the unit During normal operation green color pulses on the unit in regular intervals A change of the backlight color indicates the need to repla...

Страница 7: ...out of the drawer 3 Insert the new filter into the drawer and fit the cover onto it Be sure to insert the filters correctly observing the arrows indicating the air flow direction 4 Switch on the heat...

Страница 8: ...rol of the heat recovery unit can be divided into five sections with the set of individual symbols 1 2 4 5 3 Fig 6 Display of the control 1 Symbols for the Days of the Week and Error Statuses Error No...

Страница 9: ...heat recovery system decreases below 0 C the Drying mode will be started and the unit can only be switched off after that If the unit is switched on during Drying this mode must be completed first an...

Страница 10: ...e lowest power setting On activation of this function the user sets the return day and time dd mm yy hh mm Party An increased power function used mainly when a higher number of persons are present on...

Страница 11: ...w the default value and you can achieve the maximum allowed time by turning the switch to the right By turning the switch to the left the user can reach the minimum value 0 which is accompanied by the...

Страница 12: ...st ventilation switches CO2 sensors more wall mounted controls max 3 pieces VAC material and distribution elements as optional accessories 7 1 2 1 Boost ventilation switch The forced ventilation Boost...

Страница 13: ...cope of the granted guarantee 1 JABLOTRON LIVING TECHNOLOGY undertakes do repair a defective product free of charge during the extended guaran tee period namely a 5 years from the moment of commission...

Страница 14: ...12 Appendices Appendix 1 Control dimensions...

Страница 15: ......

Страница 16: ...Your installation partner JABLOTRON LIVING TECHNOLOGY s r o User manual 2 edition Hole ov JABLOTRON LIVING TECHNOLOGY s r o 2017 12 pages...

Отзывы: