GSM pager CA-1803BT „Athos“
6/6
MHF56801
alarm is supplied with a small current from the BB-02. Fully charging a
fully discharged battery requires 5 days. In the case of a supply voltage
outage, the BB-02 starts to generate a voltage either for the outage
duration or until it is completely discharged. While testing it or being
handled, it is possible to protect the backup battery from being
completely discharged by briefly shorting the BB-02’s terminals (the BB-
02 has to be disconnected from the power supply). This causes
disconnection of the electronics inside the back-up battery. In the case of
switch-over to BB-02 operation (after a voltage drop under 8.5V or after
complete disconnection of the battery), an SMS will be sent with
information about backup battery operation. An SMS will also be sent
after the recovery of the main power supply voltage (at least 10
minutes).
16
Emergency RESET
In the case of an emergency, when no installation MASTER code is
available, it is possible to perform an emergency RESET of the car alarm
even without the code. Such a reset causes the car alarm to be set to
factory defaults, including access codes (stated in the manual). Caution:
all pre-programmed numbers, Locator parameters, DIP and SET
parameters will be deleted. You perform an emergency reset as follows:
Turn the power supply (including back-up battery, if any) off. Pull the SIM
card out of the car alarm and insert it into a phone, enter “RESET” as a
name into the SIM card’s phone directory, and enter “0” for the
corresponding phone number. Insert the SIM card back into the car
alarm and turn the power supply on. The reset is indicated by 4 beeps.
Please contact us by p420 483 559 987 or +420 606 652 997.
You can also e-mail us your suggestions to improve our services and
products to
.
17
Specification
Power supply
12/24V DC (8-32V)
Stand-by consumption
max. 20 mA
Max. consumption (during GSM communication)
1 A
GSM band
E-GSM / GPRS 900/1800MHz
Transmitted power
2 W for GSM900, 1 W for GSM1800
Frequency 868.5MHz
Operational temperature
-20°C to +70°C
Output SIR
+12V (24V), max. load 1.3A
Immobilization
8A permanently, 12A intermittently
Central locking outputs
max. 200mA, to GND
pulses 0.5s, 4s or 60s (optional)
Complies with
ECE Regulation No. 97.00
Can be operated according to ERC/DEC98(20,21),ERC REC 70-03
Safety EN
60950
EMC
EN 55022, EN 50130-4
Radio interference
ETSI EN 301419-1, EN 301511,
ETSI EN 300220, ETSI EN300 328
JABLOTRON ALARMS a.s. hereby declares that the CA-1803BT
is in
compliance with the essential requirements and other relevant provisions of
Directive
1999/5/EC
The original of the conformity assessment can be
found at
www.jablotron.com
, Technical Support section
Note:
Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer after
use.
97RAI-01 4532
E
8