GSM pager CA-1803BT „Athos“  

 

 

6/6 

MHF56801

 

 

 

 

 

 

alarm is supplied with a small current from the BB-02. Fully charging a 
fully discharged battery requires 5 days. In the case of a supply voltage 
outage, the BB-02 starts to generate a voltage either for the outage 
duration or until it is completely discharged. While testing it or being 
handled, it is possible to protect the backup battery from being 
completely discharged by briefly shorting the BB-02’s terminals (the BB-
02 has to be disconnected from the power supply). This causes 
disconnection of the electronics inside the back-up battery. In the case of 
switch-over to BB-02 operation (after a voltage drop under 8.5V or after 
complete disconnection of the battery), an SMS will be sent with 
information about backup battery operation. An SMS will also be sent 
after the recovery of the main power supply voltage (at least 10 
minutes). 

 

 

16 

Emergency RESET 

In the case of an emergency, when no installation MASTER code is 

available, it is possible to perform an emergency RESET of the car alarm 
even without the code. Such a reset causes the car alarm to be set to 
factory defaults, including access codes (stated in the manual). Caution: 
all pre-programmed numbers, Locator parameters, DIP and SET 
parameters will be deleted. You perform an emergency reset as follows: 
Turn the power supply (including back-up battery, if any) off. Pull the SIM 
card out of the car alarm and insert it into a phone, enter “RESET” as a 
name into the SIM card’s phone directory, and enter “0” for the 
corresponding phone number. Insert the SIM card back into the car 
alarm and turn the power supply on. The reset is indicated by 4 beeps. 
 
Please contact us by p420 483 559 987 or +420 606 652 997. 
You can also e-mail us your suggestions to improve our services and 
products to 

[email protected]

 
 

 

17 

Specification 

Power supply  

12/24V DC   (8-32V) 

Stand-by consumption 

 max. 20 mA 

Max. consumption (during GSM communication) 

1 A 

GSM band 

E-GSM / GPRS 900/1800MHz 

Transmitted power 

2 W for GSM900, 1 W for GSM1800 

Frequency 868.5MHz 
Operational temperature 

-20°C to +70°C 

Output SIR 

+12V (24V), max. load 1.3A

 

Immobilization 

8A permanently, 12A intermittently 

Central locking outputs 

max. 200mA, to GND 

 

pulses 0.5s, 4s or 60s (optional) 

 

Complies with  

ECE Regulation No. 97.00 

Can be operated according to ERC/DEC98(20,21),ERC REC 70-03

 

Safety EN 

60950 

EMC 

EN 55022, EN 50130-4 

Radio interference 

 

ETSI EN 301419-1, EN 301511,  

 

  ETSI EN 300220, ETSI EN300 328 

 

 
 
 

JABLOTRON ALARMS a.s. hereby declares that the CA-1803BT

 

is in 

compliance with the essential requirements and other relevant provisions of 
Directive 

1999/5/EC

 The original of the conformity assessment can be 

found at 

www.jablotron.com

, Technical Support section  

 

 

 Note:

 Although this product does not contain any harmful materials we 

suggest you return the product to the dealer or directly to the producer after 
use. 

 

97RAI-01 4532

 

E

8