Enrolling the detectors

 

First  of  all  select  the  mode  in  which  the  detector  should  be 

operated and then enroll it. 

Procedure: 

1.  Perform a long press of the Learn/Set button (1) until the yellow 

LED starts flashing.  

2.  When  you  release  the  button  the  relay  is  ready  to  receive  an 

enrolling  signal  from  a  detector,  confirmed  by  permanent 
lighting of the yellow LED and a flashing red LED. The number 
of flashes determines the operation mode to which the detector 
will  be  enrolled.  Operation  mode  selection  is  performed  by 
repeatedly briefly pressing the button. 

No. of red LED flashes. 

Mode 

1x  *  *  *  * 

Copy (extended) 

2x  **  **  **  ** 

Impulse 

3x  ***  ***  ***   

Change status 

4x  ****  **** 

Always switches off 

5x  *****  ***** 

Block 

1x longer lit, short pause 

Mode for deleting detectors 

Note:

 Extended copy – minimum switching time is 1 s 

 

3.  Insert  the  batteries  into  the  detector  –  it  sends  an  enrollment 

signal. 

4.  Enrolling  is  confirmed  by  alternate  flashing  of  the  LED  in  red 

and green. 

5.  When  the  enrollment  procedure  has  been  done  correctly,  the 

relay goes back to its normal operating mode – the green LED 
is  ON.  This  means  that  if  you  want  to  enroll  the  next  detector 
you must repeat the whole enrollment procedure. 

Erasing the detectors

 

1.  Perform a long press of the Learn/Set button (1) until the yellow 

LED starts flashing. Now release the button and the yellow LED 
indicates permanently and the red LED flashes. 

2.  By  repeated  pressing  (5x)  of  the  button  (1)  select  the  mode 

when the red LED lights constantly with a regular short pause. 

3.  Insert the batteries into the detector which is to be erased. 
4.  Erasing  the  detector  from  the  relay  is  confirmed  by  alternate 

flashing of the red / green LED indicators. 

5.  When  the  erasing  procedure  has  been  done,  the  relay  goes 

back to its normal operating mode. 

 

Common timer setup

 

1.  Perform a long press of the Learn/Set button (1) until the yellow 

LED starts flashing. Now release the button and the yellow LED 
indicates permanently and the red LED flashes. 

2.  Perform a long press of the Learn/Set button (1) again until the 

flashing  of  the  red  LED  changes  to  permanent  lighting  of  the 
green LED. 

3.  When  the  button  is  released  the  green  LED  will  flash.  The 

number  of  flashes  determines  the  pre-set  period  of  the 
Common timer. 

4.  By repeated pressing  of the  button (1) select the required time 

of  the  common  timer.  Table  shows  5  default  options.  Those 
values  can  not  be  changed  in  stand-alone  mode.  When  it  is 
pre-set  by  F-Link  to  a  different  time  than  is  mentioned  (not  to 
predefined/default  values),  the  green  LED  lights  with  a  regular 
short pause. 

 

No. of green LED flashes. 

Timer period 

1x  *  *  *  * 

1 s (default) 

2x  **  **  **  ** 

1 min 

3x  ***  ***  ***   

3 min 

4x  ****  **** 

15 min 

5x  *****  ***** 

30 min 

1x longer lit, short pause 

Different settings (via F-Link) 

 

5.  Confirm  the  selected  value  by  very  long  pressing 

(more than 6 s) until the red/green LED indicators start flashing. 
Settings are saved. 
 
 
 
 
 

Note

:  no  activity  for  longer  than  1  minute  terminates  the 

setup/enrollment  mode,  saves  the  changes  and  goes  to  normal 
operating  mode.  To  leave  the  setting/enrollment  mode,  press  the 
Learn/Set  button  (1)  for  a  very  long  time  (more  than  6 s) – 
a red/green  LED  indicator  flashes  briefly  and  the  relay  goes  to  its 
normal operating mode. 

Operational status - optical indication 

LED indication 

Mode 

ERR 

(yellow) 

OFF 

Everything OK 

ON 

(stand-alone mode) 

Setting 

ON 

(operation with 

control panel) 

Loss of 

communication 

or 

Internal settings 

entered 

Flashes 1/s 

Low Battery from 

detector(s) 

RELAY 

(red/green)

 

RED LED ON 

Relay ON 

GREEN LED ON 

Relay OFF 

GREEN flashes  

Blocking when OFF 

GREEN/RED 

 flashes  

Blocking when ON 

Reseting the relay  

A  full  relay  reset  and  complete  erasing  of  all  enrolled  devices  is 

performed by very long pressing (more than 6 s) of the button (1). It 
is  indicated  by  alternate  flashing  in  red/green  of  the  RELAY  LED 
simultaneously  with  permanent  lit  of  the  ERR  LED.  The  Learn/Set 
button must be then released (within 3 s) and then shortly pressed 
again  (also  within  3 s).  The relay  reset  is  confirmed  by  quick 
alternate  flashing  in  red/green  of  the  RELAY  LED  with  a  yellow 
ERR  LED.  After  this  only  the  green  and  yellow  LED  stays  lit.  A 
reset  doesn´t  erase  an  enrolled  control  panel  currently  in  service 
mode (in this case the yellow LED will not be lit). 

Technical specifications 

Operational power 

100-

230 V / 50-60 Hz

 

Own power consumption for 230 V AC (min / max) 

 

0.2 W / 0.7 W 

Communication band 

868.1 MHz, Jablotron protocol 

Antenna 

Internal 

Contact rating - protection class II: 

 

Maximum switching voltage 

250 V AC 

Resistive load 

FRVij 

 

max.16 A 

Inductive, capacitive load 

FRVij 

 

max.

 

8 A 

Halogen lights 

max. 1000 W 

Minimum switching DC power 

0.5 W 

Recommended connection wires: 
 

max. 2 x 1.5 mm

; max. 1 x 2.5 mm

2

 

IP covering 

 

 

IP-20 (according to EN 60529), IP-40 (with a front panel) 

Dimensions 

49 x 49 x 26 mm 

Weight 

65 g 

Operational temperature range 
 

-10 to + 40°C, relative humidity 75% no condensation 

Complies with 

ETSI EN 300 220-1, EN 50130-4 

 

 

EN 55022, EN 60950-1 

Can be operated to 

ERC REC 70-03 

 

 

The 

AC-160-C 

complies with the essential requirements of: 

Directive   1999/5/EC, 2012/65/EU, when used for its intended 
purpose. The original of the conformity assessment can be 
found at 

www.jablotron.com

, Technical Support section

 

Note: Although this product does not contain any harmful 
materials we suggest you return the product to the dealer or 
directly to the producer after use

 

Отзывы: