Restore on AC Power Loss
The J2 485 has three options should AC power become lost and then later restored. There
is Power Off (stay turned off), Power On (turn on when AC restored), or Last State. The
Last State setting will cause the unit to turn on (if it was on when AC power was lost), or
it will stay off ( if the unit was off when AC power was lost).
Wake on LAN
Wake on LAN is enabled by default but can be disabled in this screen.
RTC Configuration
The RTC has an alarm function that can be used to turn the J2 485 on at a preset time of
day. This function is enabled by this setting. The wake up time can also be set here.
J2 also has a utility option available to set the wake-up time from Windows. This is more
versatile than the BIOS setting, as it allows for more than one time of day to be set, as