Ballast Input Voltage
Maximum Amp Draw
Bulb Identifier
Output (lumens)
Color Temp
Fuse Specifications
20A Max (initial)
D1S
3200 lm
4100º K
3.18A max (steady state)
(35W)
10A Max (initial)
D1S
3200 lm
4100º K
1.59A Max (steady state)
(35W)
Part Number
Item
Part Number
1700981
2
3150831
1700991
2
3150811
1701001
2
3150821
1701011
3a
6600311
1701021
3b
6600321
1701031
4
3150801
3254371
5
7147290
INSTRUCTION SHEET - Part #6542110 Rev
E
.
01
-2
9
-
2016
Wire Harness
Fuse, 20 Amp Slow Blow
HID Lighting System, 12 Volt Trap
HID Lighting System, 12 Volt Spot
HID Lighting System, 24 Volt Flood
HID Lighting System, 24 Volt Trap
HID Lighting System, 24 Volt Spot
Ballast Assembly, 35W 24V
Fuse Assembly
This warranty does not cover removal or installation costs, or products subjected to misuse, neglect, accident, improper installation, or use in violation of instructions furnished
by Speaker. This warranty is Speaker's exclusive obligation with respect to products sold hereunder. NO OTHER WARRANTIES OF ANY KIND ARE MADE, EITHER
EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Under
no circumstances shall Speaker be liable for incidental or consequential damages of any kind arising out of the sale or use of any Speaker product.
ONE YEAR WARRANTY:
All Speaker products sold hereunder are warranted to resellers and commercial industrial users for one (1) year from date of purchase against
defects in material and workmanship. Products found to be defective during the warranty period will be repaired or replaced (at Speaker's option) without charge. The defective
product must be returned transportation prepaid with proof of date of purchase to J.W. Speaker Corporation, Service Dept., W185 N11315 Whitney Drive, Germantown,
Wisconsin 53022. The repaired or replaced product will be returned to the purchaser with transportation prepaid by Speaker. Contact the factory for a Return Goods
Authorization (RGA).
HID Beam, 12-24 Volt, Spot
Ballast Assembly, 35W 12V
HID Lighting System, 12 Volt Flood
HID Beam, 12-24 Volt, Flood
HID Beam, 12-24 Volt, Trap
SYSTEM SPECIFICATIONS
Series 9700
Ambient
Operating
Temperature
Arc strikes but will not
sustain
Disconnect power; replace beam; reconnect power; attempt re-start
WARRANTY PROCEDURE:
Contact your dealer for all warranty claims. All components must be returned for warranty claims on systems purchased as complete assemblies
(see Parts List for items tagged "complete"). Components purchased separately (items 1-5 on the Parts List) may be individually returned.
Beam burned out
Disconnect power; replace beam; reconnect power; attempt re-start
Ballast Failure
Disconnect power; replace ballast assembly; reconnect power; attempt re-start
Unit does not light
Low/no voltage input to unit
Repair or replace defect in input system
-40 to 85C
Model 9710 (35-Watt,
12 volt) System
9-16 VDC
Check input current (see specifications)
Repair or replace defective input system
Beam burned out
20 Amp Slow Blow
(BUSS MSD-L)
Model 9720 (35-Watt,
24 volt) System
18-32 VDC
-40 to 85C
20 Amp Slow Blow
(BUSS MSD-L)
Inspect/Possible Cause
Solution
Check electrical connections and cords
Replace if damaged
Remove power from HID system. Wait 30 seconds and reapply power
HID Internal Protection Circuit
Check wiring polarity
Unit must be wired positive to the red lead and negative to the black lead
Description
Description
WARNING
Disconnect input power to ballast before servicing unit
TROUBLESHOOTING CHART
Check in-line fuse
Replace fuse
PARTS LIST
Item
Problem
Complete
Complete
1
Complete
Complete
Complete
Complete
J.W. Speaker Corp.
N120 W19434
Freistadt Rd
Germantown, WI 53022-0489 USA
262.251.6660 / 800.558.7288
2
1
3a
3b
4
5