EDID Management Commands
EDIDH[x]B[y]
.
Input port [y] learns the EDID from output
port [x].
If the EDID data is available and the audio
part supports not only PCM mode, then
force-set it to support PCM mode only. If
the EDID data is not available, then set it
as initialized EDID data.
EDIDH4B3
EDIDPCM[x].
Set the audio part of input port [x] to PCM
format in EDID database. X=1~8.
EDIDPCM1
EDIDG[x].
Get EDID data from output [x] and display
the output port number. X=1~8.
Hexadecimal
EDID data and
carriage return
character
EDIDMInit.
Restore the factory default EDID data of
every input.
EDIDMInit.
EDIDM[X]B[
Y].
Manually EDID switching. Enable input[Y]
to learn the EDID data of output[X]. If the
EDID data is not available, then set it as
initialized EDID data. X/Y=1~8.
EDIDM7B6
EDIDUpgrad
e[x].
Upgrade EDID data via the RS232 port.
[x] is the input port, when the value of X is
9, it means to upgrade all input ports.
When the switcher receives the command,
it will show a message to prompt you to
send EDID file (.bin file). Operations will be
canceled after 10 seconds. Please cut off
all connections of HDBaseT ports.
Please send the
EDID file
EDID/[x]/[y].
Set the EDID data of input port [x] to
built-in EDID No.[y].
[y]=1~6, correspond to the 6 embedded
EDID data separately
EDID/7/1
RS232 CONTROL COMMANDS