MAIN
=
100
TNK
Main tank capacity, in units selected
AUX? N AUX? Y
TNK
Y—Yes—aircraft has auxiliary tanks
AUX
=
0
TNK
Auxiliary tank capacity
MIN
=
45
LOW
Alarm limit in minutes for low time in
tanks
REM
=
10
LOW
Alarm limit for low fuel quantity in
tanks, in units selected
CARB? N CARB? Y
Y—Yes—carbureted engine
SAVE -N SAVE -Y
DOT
Whether excluded measurements are
retained after power off.
Y—Exclusions are saved.
N—Exclusions are not saved
SAVE -N SAVE-Y
LOP
Whether Lean of Peak method is retained
after power off.
Y—Lean of Peak is default.
N—Rich of Peak is default
MIN 10 (0 31)
BRT
Set low light display brightness from 0 to
31.
END Y END N
Y—Yes to exit; N—No to review list again
Fuel Flow Alarm Limits, Units, Fuel Capacity
Fuel Flow Units
Selects the units in
all
measurements where fuel quantity or fuel rate is
displayed. If you change this parameter, it does
not
change the numerical
value of the fuel tank capacity. You must do this manually. For example
if you change from Gal. to Lbs., the tank capacity will be interpreted as
50 Lbs. rather than 50 gallons; the EDM-760/790 will not convert 50 Gal
to equivalent pounds.
Page 50
Engine Data Management