background image

REV 12-28-2018 

19 

Содержание Turbo Towel 18500

Страница 1: ...tion Page 3 Specifications Page 4 Important Safety Instructions Page 5 Product Dimensions Page 6 12 Installation Page 13 Installation and Operating Safety Page 14 Operating Instructions and Maintenance Page 15 Troubleshooting Page 16 Drawings REV 12 28 2018 1 ...

Страница 2: ...or of the can Key number can be found on the tag that comes attached to the keys There may be more than one key number depending on unit Please keep this information with your records MODEL ____________________________ SERIAL ____________________________ KEY NUMBER S _____________________ DATE PURCHASED ___________________ DISTRIBUTOR _______________________ J E Adams Industries 1025 63rd Ave S W ...

Страница 3: ...ications Blower 1 High performance Regenerative blower 120vac 20 amps 60hz 220 Volt model Unit specifications 18500 220V Voltage 220vac 60hz Amperage 1 20 amp service is required for this unit dedicated line Blower specifications Blower 1 High performance Regenerative blower 220vac 6 amps 60hz DUTY CYCLE 6 minutes on 4 minutes off NOTE UNIT INTENDED FOR COMMECIAL USE ONLY ...

Страница 4: ...rea consoles door panels etc Decorative trim pieces such as these can become damaged from contact with chemicals SAVE THESE INSTRUCTIONS Installation Instructions Determine location to mount unit DANGER THIS EQUIPMENT INCORPORATES PARTS SUCH AS SWITCHES MOTORS OR THE LIKE THAT TEND TO PRODUCE ARCS OR SPARKS THAT CAN CAUSE AN EXPLOSION WHEN LOCATED IN GASOLINE DISPENSING AND SERVICE STATIONS INSTAL...

Страница 5: ...REV 12 28 2018 5 PRODUCT DIMENSIONS ...

Страница 6: ...se hanger can be installed near boom home position against wall Optional 18000 NH nozzle holder can be installed near boom home position against wall Turbo Towel unit is typically installed high in the bay but underneath of boom if using boom It can be installed to the left or right of boom right example shown Hose joining boom and Turbo Towel should be relaxed and not taut Boom is typically insta...

Страница 7: ...sign can be installed anywhere in bay Optional 18000 HH hose hanger can be installed near boom home position against wall Optional 18000 NH nozzle holder can be installed near boom home position against wall Axis of motor must always remain horizontal Mounting unit flat as shown can only be done in sheltered environment free of dust and moisture Hose joining boom and Turbo Towel should be relaxed ...

Страница 8: ...e plate engage structure capable of supporting 100 lbs minimum Turbo Towel cover hooks over top of base plate so surface unit is mounted needs to be reasonably flat so this spacing is maintained Cover screw hole alignment could also be compromised if mounting surface is extremely uneven ...

Страница 9: ...ach conduit connector should be routed through adjacent cavity blower bottom and blower mounting bracket Liquidtite conduit can be routed to these two connectors one for power to motor the other to thermal protection which is wired to motor contactor ...

Страница 10: ...REV 12 28 2018 10 120VAC Motor Wiring Instructions Ground screw is tucked underneath capacitor 8mm nut 5mm thread 10 ring terminal ...

Страница 11: ...REV 12 28 2018 11 220VAC Motor Wiring Instructions Ground screw is tucked underneath capacitor 8mm nut 5mm thread 10 ring terminal ...

Страница 12: ...0V scenario showing a shut off box with motor contactor NOTE TURBO TOWEL SHOULD BE INSTALLED AND SET UP PER LOCAL ELECTRICAL CODES BY QUALIFIED ELECTRICIAN 120VAC Example Signal wire coming from wash bay s equipment selector switch could be many voltages and AC or DC Determine signal attributes and purchase compatible motor contactor ...

Страница 13: ...rmine signal attributes and purchase compatible motor contactor EXTERNAL BLOWER CONTROL WIRING SCHEME When wiring direct to the rotary switch in a carwash bay below is a typical 220V scenario showing a shut off box with motor contactor NOTE TURBO TOWEL SHOULD BE INSTALLED AND SET UP PER LOCAL ELECTRICAL CODES BY QUALIFIED ELECTRICIAN ...

Страница 14: ...from motor air intake 7 Inspect the blower at regular intervals for damage or worn parts Replace parts immediately never operate a unit with damaged parts 8 Use only genuine OEM replacement parts END USER OPERATING SAFETY INSTRUCTIONS 1 Use only for vehicle detailing 2 Do not permit children to operate this unit 3 Close supervision is necessary when using near children or those who need assistance...

Страница 15: ...over and on blower should be inspected weekly to ensure clear of debris and unrestricted Periodically inspect electrical wires and connections for wear or fatigue Inspect hoses and blower nozzle for wear once a week Clean housing with a stainless steel cleaner as needed Decals can be cleaned with mild soap and water Once per month the stainless steel cabinet should be removed and the inside compon...

Страница 16: ...REV 12 28 2018 16 Troubleshooting 120V example ...

Страница 17: ...REV 12 28 2018 17 ...

Страница 18: ...REV 12 28 2018 18 ...

Страница 19: ...REV 12 28 2018 19 ...

Страница 20: ...REV 12 28 2018 20 ...

Страница 21: ...REV 12 28 2018 21 ...

Страница 22: ...REV 12 28 2018 22 ...

Отзывы: