Changing Settings: Quick Programming Method
Digital control panel/timer unit:
Unit may be programmed when received depending on information given
at that the time of order.
To program, follow the instructions below:
1. Turn unit off.
2. Hold coin switch lever in the down position.
3. Turn unit on.
4. Units display “t4” after s short boot up sequence.
5. Release coin mechanism switch lever.
6. As soon as coin mech switch lever is released, "No PU" will appear
(number of pulses) for a short time and then will automatically scroll to the
input quantity. The unit now displays a two digit number. This is the
minimum number of coins to make the unit engage for the programmed
time. “00” unit is free air, 01 for 1 coin, 02 for two coins, etc. Adjust by
using + or – buttons on the control panel.
Note:
vacuum and air
compressor are not able to be priced or timed at separate values.
The programmed price gives you the programmed time
regardless of function chosen.
7. Press i button to continue: Unit now advances to "Dur" (duration or
amount of time per coin) on the display and will automatically scroll to the
amount of time in seconds per coin. Adjust this amount by using + or –
buttons. Example: For 4 minutes of vend time for $ 0.75 – using the plus
or minus button set the duration to 80. This means 80 second per coin
(Quarter) for a total of 240 seconds or 4 minutes running time.
(note: this
parameter will not show up if the unit is set to free vend, “00”, in the
previous step)
.
8. Press i button to continue and unit will display "COnn" (compressor) for a
short time and then automatically scroll to the compressor operation
mode. Choose which mode you would like by using the +/- buttons; "no" =
none or no compressor, "denn" = on demand, and "cont" = continuous.
"Cont" is recommended as it seems to cause the least amount of
confusion to the end user.
9. Press i button to continue and unit will now display "nnod" which is a
setting for a modem (Y or N). Most applications will not have a modem so
this will need to be set to "N" (no).
10. Press i button to continue and unit now displays "End".
Turn unit off for 10 seconds and the back on. Now controller has the new
parameters.
Counter:
To access the counter:
In normal operation mode, press "i" button and just after the beep press the
"minus" button (you must be quick - may have to do this 2-3 times).
3/30/2011