I
NITIAL OPERATION
5.6.4. Check EMERGENCY STOP function
WARNING
Danger from faulty EMERGENCY
STOP
A non-functioning EMERGENCY STOP impairs
the safety of your product.
I
Do not use the product
I
Have the product repaired
1. Relieve the product
PROFI 6 TI
.
2. Move product
PROFI 6 TI
by using the con-
troller.
3. Press the EMERGENCY STOP button during
the movement.
All movement of your product must stop. Actuating
the control elements must not cause any move-
ment.
I
Release the EMERGENCY STOP button.
5.6.5. Check lifting limiter
WARNING
Danger from chain fracture
If the buffers are damaged, inadmissibly high
loads may act on the chain upon actuation of the
lifting limiter. The chain may break.
I
Do not use the product
I
Have the product repaired (replace buffer)
1. Move the unloaded load hook until just short
of the upper end position.
2. Stop immediately before reaching the end po-
sition and then carefully (by repeatedly press-
ing the control element) move to the end posi-
tion.
3. The movement of the chain must be stopped
due to deformation of the buffer. The engine
will stall in the process.
4. Following successful testing, the buffer must
be unloaded.
Doc.-No.: VA057988-10-OM-EN-0821-62-1
Page
33
of 62