background image

INSTRUCTIONS FOR OPERATIONS

  |  

SELENIUM Pneumatic Seed Meter

  |  

  |  

J.Assy Agricultural 

 |  

INSTRUCTIONS FOR OPERATIONS

11

10

Seed meter window

Selenium

 has a window that 

offers the possibility to monitor 
the singulation of the seeds in real 
time. To open the window, simply 
slide it as shown in the side image.

After the singulation check, keep 
the window closed. 

Maintenance

Preventive maintenance before planting

1. 

Crop kit::

Check the 

disc, singulator and ejector

. Replace the

crop kit when there is excess wear in any of the 
following parts:

3. 

Powder graphite in the seed meter:

Make sure 

the meter is well lubricated with 

powdered graphite before each planting

, if not, 

apply powdered graphite in the meter 

before filling 

it with seed

Singulator

Lobes

Singulator

Lobes

Disc

Ejector 

Disc

Hole

2. 

Vacuum Seal:

Check for excessive wear, cracks or holes in the 
vacuum seal. If any of the above items are present, 

replace the seal.

Check for excessive wear, cracks or holes in the 
vacuum seal. If any of the above items are present, 

replace the seal.

4. 

Graphite in the disc:

Check if the graphite on the back 
of the disc (side with the ejector 
is worn and, if so, apply J. Assy 
Lubricant Graphite Spray to the 
entire surface of the disc).

STEP BY STEP

TO REPLACE THE SEAL:

A.

Remove the vacuum seal from 

  the meter lid by 

pulling it up

.

B.

First assemble the 

ends

 of the 

  new seal in the meter lid.

C.

Fit the entire 

vacuum seal

 into the 

  meter lid by pressing it 

down

.

IMPORTANT:

Always keep the back of the disc well graphited 
to achieve a good lifespan of the vacuum seal.

Содержание Selenium

Страница 1: ...OPERATOR S MANUAL vers o 1 0...

Страница 2: ...tion 6 Crop kit mounting 7 Crop exchange 8 Seed meter window 10 Maintenance 10 Preventive maintenance before planting 10 Vacuum seal 10 Step by step to replace the seal 11 Step by step for graphite ap...

Страница 3: ...e Air intake Meter lid Vacuum nozzle Air intake Air intake Seed tube Designed for Selenium Meter Chassis Crop Kit More OPTIONS coming soon Edible Bean Cotton Corn Soybean Milo Cultures available Techn...

Страница 4: ...remove the meter from the mini hopper 1 Open the meter lid by turning the handle in the counter clockwise direction 2 Turn the disc latch counterclockwise Corn Kit Side of the Vacuum Side of the Seed...

Страница 5: ...andle locks Make sure the latch has closed correctly 2 Repeat the operations of the Crop kit mounting topic of this manual 3 Re open the mini hopper hatch in the direction indicated below until the en...

Страница 6: ...obes Singulator Lobes Disc Ejector Disc Hole 2 Vacuum Seal Check for excessive wear cracks or holes in the vacuum seal If any of the above items are present replace the seal Check for excessive wear c...

Страница 7: ...s of SKIPS Skips are characterized by the lack of seeds in the disc holes They can be reduced with the following actions a Verify that the crop kit has been selected correctly information in the topic...

Страница 8: ...te powder applied to the seeds and mixed uniformly is essential to make the seeds move easier inside the meter Thus they will detach from the disk at the correct time In case of humid weather increase...

Страница 9: ...October 2019 www assyag com...

Отзывы: