![J. A. Roby suroit RGV-25 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/j-a-roby/suroit-rgv-25/suroit-rgv-25_installation-and-operation-manual_3094147015.webp)
15
2.2 RATING PLATE
Certified as:
Direct vent gas fireplace
CSA 2.22-2012
ANSI Z21.50-2012
LOCATION : Quebec, Qc, Canada
Models :
RGP 25 Mistral, RGB 25 Sirocco, RGCG 25 Auster,
RGV 25 Suroit, RGC 25 Pampero, RGR 25 Loo,
RGCD 25 Mousson
SERIAL NO. :
GAS
Supply pressure
Normal
BTU/h
Burner orifice
size
Manifold
Pressure
Minimum
Normal
Burner
Natural
3.5” WC.
7” WC.
21,000
0.0905”(2.29mm)
3.5 WC.
Natural
3.5” WC.
7” WC.
23,000
#42
3.5 WC.
Natural
3.5” WC.
7” WC.
25,000
#41
3.5 W.C.
LPG GAS
8”WC.
11” WC.
21,000
#54
10 W.C.
LPG GAS
8”WC.
11” WC.
27,000
#53
10 W.C.
LPG GAS
8”WC.
11” WC.
32,000
#1/16
10 W.C.
ALTITUDE
0-610 M / 0-4500 Ft
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL
BACK
TOP
SIDES
BOTTOM
0”/ 0 cm **
17”/43.18cm **
1”/ 2.54 cm **
0”/ 0 cm **
Mantle : **
From the opening : **
See installation instructions for details
Vented gas Fireplace- Do not Use with Solid fuel
Electrical requirement for optional fan (115 Volts, 60 Hz, 0.20 Amps) normal power consumption is 23 watts.
For Use with glass door certified with this appliance only. This appliance must be properly connected to a venting
system in accordance with the manufacturer’s installation instructions. WARNING: Failure to position the part in
accordance with these diagrams or failure to use only parts specifically approved with this appliance may result
in property damage or personal injury. Keep burner and control compartment clean. See installation and operating
instructions accompanying appliance. This appliance must be installed in accordance with local code, if any; if
none, follow the current ANSI Z223.1, or CSA B149, Installation codes.
CAUTION: Hot while in operation. Do not touch the
appliance. Severe burns may result. Keep children,
clothing and furniture away.
Do not use with solid fuel
For use with glass door certified with this appliance only
Not for use in Mobile Home
Содержание suroit RGV-25
Страница 17: ...17 2 3 FIREPLACE DIMENSIONS 2 3 1 LOO RGR 25 INSERT 2 3 2 MISTRAL RGP 25 PENINSULA...
Страница 18: ...18 2 3 3 AUSTER RGCG 25 LEFT CORNER 2 3 4 MOUSSON RGCD 25 RIGHT CORNER...
Страница 19: ...19 2 3 5 SIROCCO RGB 25 PANORAMIC 2 3 6 PAMPERO RGC 25 CENTRAL...
Страница 22: ...22 3 1 1 2 LOO RGR 25 INSERT WITH SIDE EXIT 3 1 1 3 LOO RGR 25 INSERT WITH TOP EXIT...
Страница 23: ...23 3 1 1 4 LOO RGR 25 INSERT CORNER INSTALATION WITH TOP EXIT 3 1 1 5 MISTRAL RGP 25 PENINSULA WITH BACK EXIT...
Страница 24: ...24 3 1 1 6 MISTRAL RGP 25 PENINSULA WITH TOP EXIT 3 1 1 7 AUSTER RGCG 25 LEFT CORNER WITH BACK EXIT...
Страница 25: ...25 3 1 1 8 AUSTER RGCG 25 LEFT CORNER WITH SIDE EXIT 3 1 1 9 AUSTER RGCG 25 LEFT CORNER WITH TOP EXIT...
Страница 26: ...26 3 1 1 10 MOUSSON RGCD 25 RIGHT CORNER WITH BACK EXIT 3 1 1 11 MOUSSON RGCD 25 RIGHT CORNER WITH SIDE EXIT...
Страница 27: ...27 3 1 1 12 MOUSSON RGCD 25 RIGHT CORNER WITH TOP EXIT 3 1 1 13 SIROCCO RGB 25 PANORAMIC WITH BACK EXIT...
Страница 28: ...28 3 1 1 14 SIROCCO RGB 25 PANORAMIC WITH TOP EXIT 3 1 1 15 PAMPERO RGC 25 PAMPERO WITH TOP EXIT...
Страница 29: ...29 3 1 1 16 SUROIT RGV 25 SEE THROUGH WITH SIDE EXIT 3 1 1 17 SUROIT RGV 25 SEE THROUGH WITH TOP EXIT...
Страница 56: ...56 7 3 ELECTRICAL DIAGRAM OF THE SmartCase...
Страница 70: ......