27 (32)
8
Default Network Settings
Network parameter
Default setting
Remark
IP Mode
Static
IP Address
169.254.y.x
y = ((device serial number - 800 000) DIV 254) MOD 256
x = ((device serial number - 800 000) MOD 254) +1
Like APIPA if no DHCP server is
available. By scanning the
network, all available devices
can be found.
Subnet Mask
255.255.0.0
Standard Gateway
0.0.0.0
Device Name
CAN@net NT
Device password
IXXAT
Transmitted MD5-encrypted
9
Default TCP/UDP Ports
CAN@net
PC
CAN Gateway Configurator
Device scan and IP configuration:
15000/udp
Device configuration (via TCP):
19229/tcp
Device scan and IP configuration:
15001/udp
Device configuration (via TCP):
1024-65535/tcp
VCI
19229/tcp
1024-65535/tcp
Gateway (ASCII Interface)
19228/tcp
1024-65535/tcp
Bridge (CAN-Ethernet-CAN)
Slave: 19239/tcp
Master: 1024-65535/tcp
—
10
Technical Data
Ethernet Interface
10/100 MBit/s, twisted pair
Dimensions
114.5 x 99 x 22.5 mm
Weight
Approx. 150 g
Operating temperature
-40 °C to +85 °C
Storage temperature
-40 °C to +85 °C
Power supply
9 V to 36 V DC with overvoltage and polarity protection
Current consumption
Typically 110 mA at 24 V input voltage,
typically 230 mA at 12 V input voltage
Housing material
Polyamide
Galvanic isolation
1 kV DC for 1 sec
Protection class
IP20
CAN transceiver (CAN 1/CAN2)
SN65HVD251
CAN FD transceiver (CAN3/CAN4 withCAN@net NT 420)
MCP2562FDT
Max. number of bus nodes
120
CAN bus termination resistor
None
CAN baud rates
Classic CAN: 5 to 1000 kBaud
CAN FD: 5 to 8000 kBaud
CAN pass through delay
Local CAN Bridge: 15-25 μs
CAN-Ethernet-CAN Bridge: 4-6 ms
Startup time after power on
< 1 s
Processing time in Bridge mode
30 000-40 000 msg/s
Startup time
Firmware v5.1.3: min. 540 ms (configuration size 5 kB),
max. 1080 ms (configuration size 140 kB)
Firmware v6.0.0: min. 250 ms (configuration size 5 kB),
max. 790 ms (configuration size 140 kB)
Ethernet connection might add up to 1–2 seconds
CAN@net NT User Manual
4.01.0332.20000 1.7 en-US