background image

Copyright IXXAT Automation GmbH 

CAN@net II - Manual, V1.4 

Appendix 

 

 

19 

 

 

 

Picture 5-2: CAN bus termination resistor 

5.4

 

Notes on EMC 

The PC/CAN-Interface CAN@net II may only be used with a PC that has a CE-

symbol. The CAN-bus connected to the interface must have a shielded lead. The 
shield braiding must be connected with low impedance to the connector hous-
ing. 

Содержание CAN@net II

Страница 1: ...The expert for industrial and automotive communication Manual CAN net II Intelligent PC CAN Interface ...

Страница 2: ...cts please contact IXXAT in written form by Fax 49 0 7 51 5 61 46 29 e Mail support ixxat de For customers from the USA Canada Fax 1 603 471 0880 e Mail techsupport ixxat com Copyright Duplication copying printing microfilm or other forms and the electronic distribution of this document is only allowed with explicit permission of IXXAT Automation GmbH IXXAT Automation GmbH reserves the right to ch...

Страница 3: ...us connector 10 3 2 Indicators 10 3 2 1 Power LED PWR 11 3 2 2 Status LED CPU 11 3 2 3 Ethernet LED ETH 12 3 2 4 Collision LED COL 12 3 2 5 Link Data Activity LED ACT 13 3 2 6 CAN LED CAN 13 3 3 CAN bus termination 14 4 Configuration 14 4 1 Configuration Tool 14 4 1 1 Overview 14 4 1 2 Usage 15 4 2 Resetting the network parameters 15 5 Appendix 17 5 1 Technical specifications 17 5 2 Default Networ...

Страница 4: ......

Страница 5: ...terface via TCP IP the pos sibility to use the device in non Windows systems such as Linux operating sys tems Additionally two CAN net II Generic devices can be used as a bridge This makes it possible to connect two CAN networks which are far away from each other via TCP IP The CAN net II Generic devices receive the CAN messages of their CAN network and transmit them via TCP IP to the other CAN ne...

Страница 6: ...te and the manuals please contact our support department The support section on our website contains the relevant forms for your support request In order to fa cilitate our support work and enable a fast response please provide precise in formation on the individual points and describe your question or problem in de tail If you would prefer to contact our support department by phone please also se...

Страница 7: ...CAN driver VCI under Windows please refer to the VCI installation manual For the CAN net II Generic bridge mode the devices have to be configured This is described in detail in the CAN net II Generic manual 2 2 Hardware installation The CAN net II device needs a power supply and an Ethernet connection There is no further hardware installation necessary The CAN net II can be plugged and unplugged d...

Страница 8: ...3 1 Connectors and indicators of the CAN net II 3 1 1 Power connector For the power connection of the CAN net II a screw terminal is used For wir ing please ensure that the cross sectional area of the cable is larger than or equal to 0 14mm Picture 3 2 Power connector of the CAN net II Power Ethernet CAN LEDs Package lock Package lock Pin 1 ...

Страница 9: ...rnet socket The Ethernet socket is designed as a standard RJ45 socket The pin allocation is according to the Ethernet standard The Ethernet PHY has an auto crossover fea ture so the CAN net II can be connected with a crossover cable or with a 1 to 1 network cable Pin No RJ45 Signal 1 TX 2 TX 3 RX 4 connected to pin 5 5 connected to pin 4 6 RX 7 connected to pin 8 8 connected to pin 7 Table 3 2 Pin...

Страница 10: ...4 Not connected 5 Not connected 6 Not connected 7 CAN high 9 Not connected 9 Not connected Table 3 3 Pin allocation of the CAN bus connector The shield of the CAN connector is connected to the ground of the CAN bus in terface via a 1 MΩ resistor and a 1 nF capacitor For best noise immunity results the shields of the CAN cables have to be grounded 3 2 Indicators The CAN net II has six LEDs The LEDs...

Страница 11: ...er LED 3 2 2 Status LED CPU The two color green and red LED indicates the CAN net II device status Flashing mode Description Causes Hints off Device not ready Boot manager or application firmware is not starting green blinking 1 Hz Application firmware started Application signals normal operating green blinking 2 Hz Boot manager ac tive Boot manager of the device is running No application on the d...

Страница 12: ...not connected to Ethernet There is no communication green green blinking TCP IP packet s trans mitted successfully Communication taken place and was successful red red blinking TCP IP packet s not transmitted TCP IIP communication not estab lished so the cable may be damaged or no network connection Table 3 6 States of the Ethernet LED 3 2 4 Collision LED COL The yellow LED flashes with each colli...

Страница 13: ... green and red LED for CAN flashes on each CAN message trans mitted or received green if there was no error detected If the CAN controller is in the Error warning or Error passive state the LED flashes red on each message In the Bus off state the LED is continuously red Flashing mode Description Causes Hints off No CAN communication No CAN communication Device not connected to CAN green green blin...

Страница 14: ... available as a feed through connect or at IXXAT ordering number 1 04 0075 03000 4 Configuration 4 1 Configuration Tool 4 1 1 Overview The configuration tool which is installed automatically with the VCI is used to set the network parameters of the CAN net II The tool scans the network for CAN net II devices The detected devices are shown in the Device List and can be configured separately Picture...

Страница 15: ...is clicked the parameters are written to the CAN net II For success ful operation the password has to be entered The configuration can be stopped with Cancel The default settings of the network parameters are shown in the appendix 4 2 Resetting the network parameters The default settings of the network parameters can be reloaded using the DIP switch The following steps are necessary 1 Ensure that ...

Страница 16: ...film back in the bottom housing Ensure that the package lock is active again Picture 4 2 Position of the DIP switch Switch Position Signal 1 Off Normal usage default setting On Resetting of the network parameters to the default settings 2 Off Unused default setting On Unused Table 4 1 Functions of the DIP switch DIP switch ...

Страница 17: ... Max CAN message rate 21000 messages s continuous with VCI receive direction 21000 messages s burst Max CAN message rate 7200 messages s continuous with VCI transmit direction Power supply 9 V to 32 V DC Power consumption normal typically 110 mA at 24 V input voltage maximum 250 mA at 24 V input voltage Housing material Polyamide Dimensions L x B x H in mm 114 5 x 99 x 22 5 Weight approx 300 g Pro...

Страница 18: ... AIPA Subnet mask 255 255 0 0 Gateway address 0 0 0 0 Host name CAN_at_net_II_ 4 byte of MAC address as hex value_ 5 byte of MAC address as hex value Password IXXAT Transmitted MD5 encrypted Table 5 1 Default Network Settings 5 3 Accessories 5 3 1 CAN bus termination resistor IXXAT offers a bus terminal resistor as a feed through connector order number 1 04 0075 03000 Picture 5 1 Connections of th...

Страница 19: ...5 2 CAN bus termination resistor 5 4 Notes on EMC The PC CAN Interface CAN net II may only be used with a PC that has a CE symbol The CAN bus connected to the interface must have a shielded lead The shield braiding must be connected with low impedance to the connector hous ing ...

Страница 20: ... II VCI and CAN net II Generic with the article number 1 01 0086 10200 1 01 0086 10201 1 01 0086 10202 do comply with the EC directives 2004 108 EC Applied harmonized standards in particular EN 55022 2006 A1 2007 EN 61000 6 2 2005 23 08 2011 Dipl Ing Christian Schlegel Managing Director IXXAT Automation GmbH Leibnizstrasse 15 88250 Weingarten ...

Страница 21: ...een tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are de signed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in ac cordance with the instruction manu...

Отзывы: