e n g l i s h
|
7
Ixtur LI-120
Material Thickness
In addition to ferromagnetic characteristics of load material, magnetic holding force is affected by the
thickness of the material
.
The material's maximum conducting capacity for a specific magnetic field strength is achieved with a specific
threshold thickness of steel plate.
When the thickness becomes smaller than this threshold, the conducting capacity of steel plate weakens, and
at the same time, the holding force is reduced.
When steel plate thickness becomes greater than this threshold, the holding force is no longer proportional to
thickness, as the magnet has reached its full capacity.
For Automatic Lifting Magnet LI-120, the maximum magnetic holding force in the load material is rated with
steel EN S235, with minimum material thickness of 12 mm.