INSTALL GS-12-Air MIXER:
STEP 1: Plan out a safe procedure and hoist the GS-12-Air mixer to the top of the tank near the hatch
opening. Use the chain attached to the GS-12-Air mixer for lifting and supporting the weight. Keep clear of
chain and air hose to avoid entanglement.
STEP 2: Slide the required kellem grip over the air hose that will attach to the machine. Make sure kellem
grip is 6-8ft from the end and eye loop is towards the machine end of the hose. Attach the kellem grip using a
quick link to the center of the suspension chain attached to the machine. Attach air hose to hose barb on the
machine with supplied hose clamp and tighten.
STEP 3: Attach one end of the retrieval chain to the bottom of the penetration fitting with a quick link. Attach
opposite end of the retrieval chain to the quick link located on the mixer chain. Tighten both quick links with a
pliers.
STEP 4: Slowly and carefully lower the GS-12-Air mixer down to the tank floor until it is resting on the bottom.
The proper position is when the flat edge of the GS-12-Air mixer ends are resting on the floor.
For suspended configuration pick the unit up so it is just above the tank floor, but is as low as possible, and
with the mixer hanging horizontally. The discharge slots should point directly upward.
Medora Corporation
3225 Hwy 22, Dickinson, ND 58601
+1 866.437.8076 • +1 701.225.4495 • Fax +1 701.225.0002
www.medoraco.com
GS_SuspensionKit_Spec_20150918
© 2015 Medora Corporation • Dickinson, ND
Entanglement Hazard
WARNING: WHEN LOWERING OR RAISING THE GS-12-Air
MIXER, BE SURE THAT YOU AND OTHERS ARE CLEAR OF THE
ELECTRIC CORD AND CHAIN TO AVOID ENTANGLEMENT!
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Installation and Operation
GS-12-Air
10390_20200529
O&M_GS_12_Air_120V_10389_20210129 - 9