Control Panel
Positive Plug
Negative Plug
2. Installation
2-1.
Power Connection
1 Each machine has its own primary power cable, it must be connected to the mains
through a grounded power outlet on the right!
2 Power cable must be plugged into an appropriate power outlet!
3 Multimeter to check that there is power band in right.
2-2 . Accession output lines
1 Each machine has two swivel connectors, you can connect the panel tightly. Check
that well join cables , or damaged on both sides , can burn !
2 Electrode cable to the negative pole , while the workpiece (body) to the positive
pole connected . If the network is not grounded , then earthed via earthing connec
-
tion in the back of the machine !
3 Care should be taken of the electrode wire. Generally, there are two ways of switch
-
ing the rectifier welding machine: positive and negative connections . Positives:
electrode “-”, while the work on the “+ “ to . Negatives: piece work “ - “ electrode
while “+” is linked to . The proper practice mode , choose as faulty switching unsta
-
ble arc and cause a lot of splashing . In this case, switch the polarity to avoid incor
-
rect use of the machine !
4 If the work is too far away from the machine ( 50 - 100m) and secondary wire is too
long, you have to increase the wire cross -section to avoid voltage drop.
EN
26
Содержание 8HD160SPCEL
Страница 13: ...CUPRINS PARAMETRII 15 INSTALARE 16 OPERARE 17 19 PRECAU II 20 MENTENAN 20 RO 13...
Страница 34: ...www iweld hu...