Overview

The APN-S041-D3/-D4 is a built-in type small diaphragm air 
pump.
The rotary motion of the motor is converted through a con-
necting rod to the reciprocation of the diaphragm in the pump 
chamber, where gas is transferred from the inlet to outlet.

Part names

Precautions for use

‡

 

(OHFWULFDOZRUNVKRXOGEHSHUIRUPHGE\DTXDOL¿HGHOHFWULFLDQ2WK

-

erwise, personal injury or property damage may result.

‡

 Do not install the pump in a place where the pump can get wet. 
Avoid using wet gas, or internal condensation will build up and con-
sequently result in the reduction of pump performance or the short 
lives of the valve and diaphragm.

‡

 Do not use the pump in a dusty place. Be sure to provide the inlet 
with a filter to prevent foreign matters from getting into the pump. 
Otherwise, the pump performance may reduce or the lives of the 
valve and diaphragm remarkably shorten.

‡

 Do not install the pump in a corrosive or flammable gas atmos-
phere. Keep good ventilation in a working area. Ambient and gas 
temperature should not fall below 0°C or exceed 40°C.

‡

 If the compressed air (higher pressure than atmospheric pressure) 
is transferred to the pump, sharp deterioration to the lives of the 
valve, diaphragm and bearing may result. Always keep atmospheric 
or lower pressure in the suction line.

‡

 Do not tube pump heads in series. It may prevent the motor from 
starting, causing burning out or may damage the diaphragm or 
piping.

‡

 Do not tube two or more pumps in series. It may prevent the motor 
from starting and lead to a burn out.

‡

 An air injection point below the liquid level must be lower than the 
pump position. Or siphon action or back flow may result.

‡

 Use care handling the pump. Do not drop. An impact may affect 
pump performance. Do not use a pump that has been damaged to 
avoid the risk of electrical damage or shock.

‡

 Do not apply power other than that specified on the nameplate. 
Otherwise, failure or fire may result.

‡

 The pump can not start with full discharge/suction pressure. 
Remove pressure before operation. After a long period of stoppage, 
pump performance at the beginning of operation becomes occa-
sionally unstable. In this case, warm the pump up for 10 minutes 
with no discharge/suction line pressure.

‡

 Always use a suction valve to adjust an air flow.

‡

 Do not clean the pump or nameplate with a solvent  such as ben-
zine, thinner or kerosene. This may discolour the pump or erase 
printing. Use a dry or damp cloth or a neutral detergent.

Motor

Anchor point

Always fix with M3 
screws at the bottom.

Pump head

Not capable of liquid 
transfer. Air transfer 
purpose only.

,QOHW

&DVHZLWKDEXLOW
in drive unit)

2XWOHW

6SHFLILFDWLRQODEHO

Use the pump accord-
ing to the specifica-
tions on the label.

Содержание APN-S041-D3

Страница 1: ...for use 3 Overview 3 Part names 3 Identification codes 4 Installation 4 Pump mounting 4 Pipework 5 Wiring 5 Before wiring 5 Operation 6 Before a long period of stoppage 1 week or more 7 Maintenance 7...

Страница 2: ...turn off power to stop the pump and related devices before service is performed Stop operation If you notice any abnormal or dangerous conditions sus pend operation immediately and inspect solve probl...

Страница 3: ...maged pump Use of a damaged pump could lead to an electric shock or death LVSRVDO RI D XVHG SXPS Dispose of any used or damaged pump in accordance with local rules and regulations If necessary consult...

Страница 4: ...heric or lower pressure in the suction line Do not tube pump heads in series It may prevent the motor from starting causing burning out or may damage the diaphragm or piping Do not tube two or more pu...

Страница 5: ...otor without speed control D4 24VDC BLDC motor with variable speed control h Special specification QVWDOODWLRQ This section describes the installation of the pump tubing and wiring Read through this s...

Страница 6: ...ause For the APN S041 D3 red and black leads are for power voltage For the APN S041 D4 red and black leads are for power volt age Yellow and black leads are for 1 5VDC external variable signal The bla...

Страница 7: ...t a suction tube is connected to the inlet and a dis charge tube is connected to the outlet If a suction line and a discharge line are connected the other way around pumping process is inverted Check...

Страница 8: ...ct us The pump does not run Connecting rod bearing has worn Replace the connecting rod unit Contact us Motor trouble Replace the motor Contact us Suction line pressure is higher than atmospheric press...

Страница 9: ...V IRU D OHDN DQG UHWLJKWHQ as necessary HDU SDUW UHSODFHPHQW To run the pump for a long period wear parts need to be replaced periodically It is recommended that the following parts are always stocked...

Страница 10: ...LDSKUDJP The diagram has a mounting direc tion as shown 0RXQW WKH VKHHW DQG UHWDLQHU Use the Loctite 222 to the flat screws and tighten them by 1 P 3XVK GRZQ WKH GLDSKUDJP WR WKH ORZHVW SRVLWLRQ Repla...

Страница 11: ...tlet 127 The pump may fail if the tube is connected improperly 9DOYH UHSODFHPHQW 5HPRYH WKH WXEH 7DNH DSDUW WKH SXPS KHDG Remove the screws pump head valve and valve seat 0RXQW WKH QHZ YDOYH WR WKH YD...

Страница 12: ...to the inlet and the other to the outlet 127 The pump may fail if the tube is connected improperly 127 When the pump is taken apart for diaphragm valve replacement do not remove or loosen any other sc...

Страница 13: ...ontrol voltage Observe the maximum allowable discharge pressure of 0 0MPa OORZDEOH JDV WHPSHUDWXUH UDQJH LV OORZDEOH DPELHQW WHPSHUDWXUH UDQJH LV Maximum operating noise is 41dB at 1m A scale Names Ma...

Страница 14: ...ty No Part names Q ty 1 Pump head 2 40 Motor 1 2 Valve 2 61 Flat screw 2 3 Valve seat 2 62 Screw 4 4 Diaphragm 2 94 Slider 1 5 Retainer 2 95 Hose 1 33 Case 1 130 Sheet 2 L min Air flow Vacuum pressur...

Страница 15: ...14...

Страница 16: ...hina XDQJ KRX 7 QJLQHHULQJ 7UDGLQJ R WG 7 WDO XURSH PE WDO UDQFK 7 8 6 IWAKI America Inc 7 China IWAKI Pumps Shanghai Co Ltd 7 Spain XURSH PE 6SDLQ UDQFK 7 Argentina IWAKI America Inc Argentina Branch...

Отзывы: