F. GU10 socket
Light with GU10 socket with a test voltage of 230V
AC
10,00mm
G. E14 socket
Light with E14 socket with a test voltage of 230V AC
14mm
H. E27 socket
Light with E27 socket with a test voltage of 230V AC
27mm
I. Test compartments of batteries and accumulators
For testing rechargeable NiCd / NiMH accumulators and alkaline batteries with the following cell sizes: AAA (Micro), AA
(Mignon), C (Baby) and D (Mono).
Turn on the device with switch
J
and set the test voltage to 1.5 volt with switch
L
.
The test result can be read on LED display
K
.
Pay attention to good contact and correct polarity of the cell to be tested.
J. On-/Off-switch for continuity check and battery tester
Switch on the device to test batteries, accumulators and on continuity.
Note:
Switch the device off after having performed the test to save the 9 volt power supply!
K. LED display
For testing batteries/accumulators the device must be
switched on and the correct nominal voltage must be
set.
NOTE:
Batteries and accumulators have different voltages.
OK
Alkaline Battery Full
Rechargeable Battery Full
9V
1.5V
OFF
ON
L. Setting the nominal voltage
Switch for setting the nominal voltage 1.5 volt or 9 volt for batteries or accumulators.
M. Connection sockets for separate testing wire
Continuity check with separate testing wire (included in the scope of delivery). Turn on the device with switch
J
. The buzzer
sounds and the green LED
R
lights in case of conducting cables, switches, fuses, lights, etc.
Note:
It is not necessary to observe any polarity. Disconnect the testing wire immediately after use.
N. Tester for round cells
This compartment serves for testing any common round cells with a nominal value of 1.5 volt.
Turn on the device with switch
J
and set the nominal voltage to 1.5 volt with switch
L
.
The test result can be read on LED display
K
. Pay attention to good contact of the cell to be tested!