iVigil TD054AA Скачать руководство пользователя страница 16

15 

 

8. 

System 

Assembly          

 

 

 

 

 

 

Simple to install, the system supports connection of numerous devices (Ex.: 

Speed Dome Camera, P/T/Z Receiver, and etc.) 

 

Connect the double twisted cable from the keyboard to the RS-485 terminal, 

and video signal to the monitor, DVR or multiplexer to complete the main 

system connection. 

 

Control keyboard can connect up to 32 sub-systems to form one control 

system. Using the main control keyboard, each system can be controlled 

separately. 

 

 

 

 

 

 

System Connection Illustration Diagram

 

 
The system supports connections of numerous Speed Dome Cameras or 
P/T/Z Receivers, assigning a set of ID (Note! ID numbers ranges from 
1~127 and may not be repeated) to setup and control, through control 
keyboard. 
 

Connecting the Device 

Connect terminal D+ of the RS-485 from the control keyboard to 
terminal D+ of RS-485 DATA IN connector from the device; then connect 
terminal D- of the RS-485 from the keyboard (the same set of terminal) 
to the terminal D- of RS-485 DATA IN connector from the device. 
Connecting more than Two Devices 
Connect terminal D+ of the RS-485 DATA OUT connector from the 
previous device to the terminal D+ of the RS-485 DATA IN connector 
from the next device; then connect terminal D- of the previous device 
(the same set of terminal) to the terminal D- of RS-485 DATA IN of the 
next device.   

Connecting the Keyboard 
Connect terminal D+ of the RS-485 from one keyboard connection port 
to terminal D+ of RS-485 from the other keyboard connection port; then 
connect terminal D- of the RS-485 from the keyboard connection port 
(the same set of terminal) to the terminal D- of RS-485 from the other 
keyboard. 
 

 

Содержание TD054AA

Страница 1: ...Color Speed Dome Camera Manual...

Страница 2: ...stallation 13 8 System Assembly 15 9 Operation 16 10 OSD Operational Description 20 11 Quick Operational Reference Table 22 12 Appendix 24 13 Specifications 25 The author assumes no responsibility for...

Страница 3: ...lp to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchas...

Страница 4: ...AUTO FOCUS etc 2 Function key indicates the order sequence Example 2 8 ENTER meaning press the function key 2 8 and then ENTER 3 _ 001 DEVICE Indicate messages from the device and is shown on the con...

Страница 5: ...z Horizontal Rotation of 180 z Built in 6 Alarm Inputs and one Relay Output z Two types of Alarm out signal are provided NO and NC z Remote Control via RS 485 z Connects up to 127 Speed Dome Cameras...

Страница 6: ...pper x3 In Ceiling Mount 10 Embellished flush cover x1 Flush Mount 11 Embellished In Ceiling Cover x1 In Ceiling Mount 12 User s Manual x1 Outdoor Type DC12V TYPE 1 DC Adaptor x1 2 Power Line x1 3 Pow...

Страница 7: ...e Description Indoor Type Transparent Cover Black Housing Machine Housing Embellish Cover ID Number Protocol Baud Rate Setting Please Refer to Pg8 9 Alarm Input or Output Video Output Power Input Term...

Страница 8: ...t Bracket Corner Mount Bracket Machine Housing Transparent Cover ID Number Protocol Baud Rate Setting Please refer to Pg8 and Pg10 Alarm Input or Output Video Output Power Input Terminal Please refer...

Страница 9: ...8 6 Camera Setting DIP Switch setting shown below Setting 000 then the image display will show DEVICE N A Does not affect setup Indoor Type Outdoor Type...

Страница 10: ...IVE On Off Off Off PELCO Off On Off Off Reserved On On Off Off Reserved Speed Dome automatically detects the type of PELCO Protocol No Switch settings are required to set D and P Protocols BOLD Defaul...

Страница 11: ...9600 BPS On Off Off Off 4800 BPS Off On Off Off 2400 BPS On On Off Off 19200 BPS BOLD Default Settings SW2 Protocol Settings Settings Switch Number 5 6 7 8 Protocol Off Off Off Off NATIVE On Off Off O...

Страница 12: ...input and 2 sets of alarm output 1 set NO and 1 set NC Alarm Input Voltage at 5 6Vmax and Alarm Output Specification 0 5A AC120V 1A AC24V 4 RS 485 Communication Control Input and Output connector RS 4...

Страница 13: ...Output CVBS 1 0 Vp p 75 BNC 2 Alarm Input Output Terminal Each Speed Dome camera is equipped with 6 external alarm inputs and 2 sets of alarm outputs 1 set NO and 1 set NC Alarm Input voltage 5 6Vmax...

Страница 14: ...13 7 Installation Indoor Type Installation Structure Diagram In Ceiling and Flush Mounting In Ceiling Mount Flush Mount...

Страница 15: ...14 Outdoor Type...

Страница 16: ...Connecting the Device Connect terminal D of the RS 485 from the control keyboard to terminal D of RS 485 DATA IN connector from the device then connect terminal D of the RS 485 from the keyboard the...

Страница 17: ...ce depends on the angel of the joystick Zoom Wide Zoom Tele z Push the joystick clockwise for close up image narrow the angle of viewing and release the joystick to stop zooming z Push the joystick an...

Страница 18: ...t the steps 2 5 again to setup more preset points CALL PRESET POINT Enter the assigned preset number and press GO PRESET key the LCD will display XXX PRESET GO and the speed dome camera will move to t...

Страница 19: ...decide the pan direction POSITION the pan speed SPEED and also the dwell time DWELL TIME for each group 2 Group number buttons in combination with PATTERN button is used to activate a previously prog...

Страница 20: ...T key the speed dome camera will slowly precede 360 auto scan Deactivate Auto Scan Enter 9 6 GO PRESET key or push the joystick to stop auto scan CAMERA FUNCTION SETUP Enter Camera Setup Menu Under co...

Страница 21: ...22x 000 220 35x 000 255 DAY NIGHT D N MODE AE D N MODE SENSOR D N LEVEL D N MODE DAY D N MODE NIGHT FILTER DLY 0 255 1 15 SEC DAY NIGHT display is applicable only to cameras with DAY NIGHT function On...

Страница 22: ...nt Serial Number DWELL TIME sec 001 128 Alarm retention period retention meaning forever halt HOME SET UP HOME FUNCTION ON OFF Homing Function PRESET POSITION 001 128 Select Homing Point RETURN TIME m...

Страница 23: ...h the Joystick Counterclockwise Select device No Key CAM Manual Operation Focus Far FOCUS FAR Manual Operation focus Near FOCUS NEAR Iris Control to Bright IRIS OPEN Iris Control to Dark IRIS CLOSE Pr...

Страница 24: ...the Joystick Forward FOCUS NEAR Cursor Down Push the Joystick Backward FOCUS FAR Menu Enter IRIS OPEN Menu Exit IRIS CLOSE Decrease Push the Joystick to the Left Increase Push the Joystick to the Rig...

Страница 25: ...hether the 20PIN of the Speed Dome Camera has fallen off 3 Unable to control the Speed Dome Camera z Check whether the ID position is correct z Check whether the communication control output or input...

Страница 26: ...ngle 360 Rotation Vertical Rotational Angle 8 90 Precision Degree Horizontal Vertical 0 25 Preset Points 128 Preset Points Group setup 6 Groups ID position setup 1 127 Camera Sensor Type 1 4 CCD Image...

Страница 27: ...mposite 1 0 Vpp 75 BNC 22X optical zoom Focal Distance f 3 9 85 8 mm 5 Iris F1 6 3 7 5 35X optical zoom Focal Distance f 3 43 120 mm 5 Iris F1 6 4 5 5 Focus Mode Auto Manual Push Auto Iris Control Aut...

Страница 28: ...RS 485 Alarm Input 6 Alarm Inputs Alarm Output 1Set NC Normal close 1Set NO Normal open 0 35A AC120V 0 5A DC24V Alarm Output Mode Lock onto the last Alarm Input Environment Operating Temperature 10 C...