background image

All manuals and user guides at all-guides.com

all-guides.com

Содержание 20CZ-512

Страница 1: ...All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...4 3 System Connection 5 5 Operation 7 5 1 PTZ Control 7 5 2 Preset Setting 7 5 3 Call Presets 7 5 4 Lens Control 7 5 5 Auto Scan Control 8 5 6 Auto Tour Scan 8 5 7 IR Far Near Light Switch 8 5 8 Error Correction for Presets 9 5 9 Restore Factory Setting 9 6 RS485 Data Cable Connection 9 7 Appendix 10 1 DIP Switch setup 10 II Shortcuts Operation 15 8 Trouble Shooting 17 All manuals and user guides ...

Страница 3: ... 15 20 adjustable IR LEDs and Lens are always synchronized no blind monitor position 2 2 2 2 Specification Specification Specification Specification Model IR Variable Speed Dome Camera Power Supply Output DC12V 5 5A Input AC100V 240V 50 60Hz Power Max 15VA IR Off 36VA IR On Output Voltage DC12V Pan Tilt Speed 0 5 20 sec Pan Range 0 360 Continuous Tilt Range 0 90 IR Far Light switch 6 times default...

Страница 4: ...on can carry on this installation B Please refer to installation instructions C Speed dome installation is sure to use clean gloves please avoid using metal hard objects or hands directly touch the down cover D After installation please use soft towel to clean the down cover when necessary The acid sweat mask of fingerprint will corrode the coating of down cover and scratch on down cover will caus...

Страница 5: ...0 OFF Baud Rate Switch 9 10 setting Max transmission distance M 9 10 2400BPS 0 0 1800 4800BPS 1 0 1200 9600BPS 0 1 800 19200BPS 1 1 600 Notice Notice Notice Notice please please please please restart restart restart restart the the the the camera camera camera camera after after after after setting setting setting setting switch switch switch switch All manuals and user guides at all guides com ...

Страница 6: ...2 Suspended Mount Optional 4 2 4 2 4 2 4 2 Installation Installation Installation Installation Steps Steps Steps Steps A Please take the wall bracket as a template to mark the screw positions of the four location holes Drill the holes and put the supplied screw inside The dimension of the holes as followed Wall Wall Wall Wall Mount Mount Mount Mount All manuals and user guides at all guides com a ...

Страница 7: ...at washers D Please clean up the stains on the dome cover after installed 4 4 4 4 3 3 3 3 System System System System Connection Connection Connection Connection 1 According to the label on the main connection line Please connect the power cable video control cable correctly connect RS485 cable to its corresponding cable connector and then connect the cable connector to its socket The connection i...

Страница 8: ...Note Note please please please please swathe swathe swathe swathe the the the the waterproof waterproof waterproof waterproof belt belt belt belt to to to to the the the the connector connector connector connector if if if if you you you you install install install install outside outside outside outside All manuals and user guides at all guides com ...

Страница 9: ...Call Call Call Call Presets Presets Presets Presets Firstly input the Presets number on the keyboard then press the Call Presets button the intelligent Dome will rotate to the Presets that has been previously set after the operation Call Call Call Call methods methods methods methods varies varies varies varies in in in in different different different different control control control control met...

Страница 10: ... Sec Call 63 preset 20 Sec Call 64 preset 5 6 5 6 5 6 5 6 Auto Auto Auto Auto Tour Tour Tour Tour Scan Scan Scan Scan The dome camera support auto tour scan For the shortcut operation of tour scan presets take the appendix appendix appendix appendix II II II II as reference 5 7 5 7 5 7 5 7 IR IR IR IR Far Near Far Near Far Near Far Near Light Light Light Light Switch Switch Switch Switch 1 Setting...

Страница 11: ...utor If you need more devices an extra distributor will be needed D Farthest distance of RS485 communication cable is 1800 meters Due to different baud rate transmission distance will be different For longer transmission distances an extra control code distributor or amplifier will be needed E In order to avoid the interference please keep the RS485 cable away from high voltage cable and separate ...

Страница 12: ...1 0 0 0 18 0 1 0 0 1 0 0 0 19 1 1 0 0 1 0 0 0 20 0 0 1 0 1 0 0 0 21 1 0 1 0 1 0 0 0 22 0 1 1 0 1 0 0 0 23 1 1 1 0 1 0 0 0 24 0 0 0 1 1 0 0 0 25 1 0 0 1 1 0 0 0 26 0 1 0 1 1 0 0 0 27 1 1 0 1 1 0 0 0 28 0 0 1 1 1 0 0 0 29 1 0 1 1 1 0 0 0 30 0 1 1 1 1 0 0 0 31 1 1 1 1 1 0 0 0 32 0 0 0 0 0 1 0 0 33 1 0 0 0 0 1 0 0 34 0 1 0 0 0 1 0 0 35 1 1 0 0 0 1 0 0 36 0 0 1 0 0 1 0 0 37 1 0 1 0 0 1 0 0 38 0 1 1 0 0...

Страница 13: ...0 72 0 0 0 1 0 0 1 0 73 1 0 0 1 0 0 1 0 74 0 1 0 1 0 0 1 0 75 1 1 0 1 0 0 1 0 76 0 0 1 1 0 0 1 0 77 1 0 1 1 0 0 1 0 78 0 1 1 1 0 0 1 0 79 1 1 1 1 0 0 1 0 95 1 1 1 1 1 0 1 0 81 1 0 0 0 1 0 1 0 82 0 1 0 0 1 0 1 0 83 1 1 0 0 1 0 1 0 84 0 0 1 0 1 0 1 0 85 1 0 1 0 1 0 1 0 86 0 1 1 0 1 0 1 0 87 1 1 1 0 1 0 1 0 88 0 0 0 1 1 0 1 0 89 1 0 0 1 1 0 1 0 90 0 1 0 1 1 0 1 0 91 0 0 1 1 1 0 1 0 92 0 0 1 1 1 0 1 0...

Страница 14: ...126 0 1 1 1 1 1 1 0 127 1 1 1 1 1 1 1 0 128 0 0 0 0 0 0 0 1 129 1 0 0 0 0 0 0 1 130 0 1 0 0 0 0 0 1 131 1 1 0 0 0 0 0 1 132 0 0 1 0 0 0 0 1 133 1 0 1 0 0 0 0 1 134 0 1 1 0 0 0 0 1 135 1 1 1 0 0 0 0 1 136 0 0 0 1 0 0 0 1 137 1 0 0 1 0 0 0 1 138 0 1 0 1 0 0 0 1 139 1 1 0 1 0 0 0 1 140 0 0 1 1 0 0 0 1 141 1 0 1 1 0 0 0 1 142 0 1 1 1 0 0 0 1 143 1 1 1 1 0 0 0 1 144 0 0 0 0 1 0 0 1 145 1 0 0 0 1 0 0 1 ...

Страница 15: ...180 0 0 1 0 1 1 0 1 181 1 0 1 0 1 1 0 1 182 0 1 1 0 1 1 0 1 183 1 1 1 0 1 1 0 1 184 0 0 0 1 1 1 0 1 185 1 0 0 1 1 1 0 1 186 0 1 0 1 1 1 0 1 187 1 1 0 1 1 1 0 1 188 0 0 1 1 1 1 0 1 189 1 0 1 1 1 1 0 1 190 0 1 1 1 1 1 0 1 191 1 1 1 1 1 1 0 1 192 0 0 0 0 0 0 1 1 193 1 0 0 0 0 0 1 1 194 0 1 0 0 0 0 1 1 195 1 1 0 0 0 0 1 1 196 0 0 1 0 0 0 1 1 197 1 0 1 0 0 0 1 1 198 0 1 1 0 0 0 1 1 199 1 1 1 0 0 0 1 1 ...

Страница 16: ...0 1 1 1 1 242 0 1 0 0 1 1 1 1 243 1 1 0 0 1 1 1 1 244 0 0 1 0 1 1 1 1 245 1 0 1 0 1 1 1 1 246 1 0 1 0 1 1 1 1 247 1 1 1 0 1 1 1 1 248 0 0 0 1 1 1 1 1 249 1 0 0 1 1 1 1 1 250 0 1 0 1 1 1 1 1 251 1 1 0 1 1 1 1 1 252 0 0 1 1 1 1 1 1 253 1 0 1 1 1 1 1 1 254 0 1 1 1 1 1 1 1 255 1 1 1 1 1 1 1 1 Notice Notice Notice Notice some some some some protocols protocols protocols protocols and and and and addres...

Страница 17: ...et 62 preset Left and Right Scan 15 S Set 63 preset Left and Right Scan 20 S Set 64 preset Start 1st Tour Call 41 preset corresponding with 1 16 presets Start 2nd Tour Call 42 preset corresponding with 17 32 presets Start 3rd Tour Call 43 preset corresponding with 65 80 presets Start 4th Tour Call 44 preset corresponding with 113 128 presets Start 5th Tour Call 45 preset corresponding with 129 144...

Страница 18: ...ng 36 preset Start Left and Right Scan Call 38 preset Set IR far near light Set 246 preset twice Clear Left and Right Limit position Setting 38 preset Preset Error Correction Call 34 preset Restore Factory Setting Setting 40 preset All manuals and user guides at all guides com ...

Страница 19: ...onnected or reversed 3 Incorrect RS485 cable wiring 1 Reset the DIP Switch according to the DIP switch chart 2 Check 485 bus controls 3 Check the wiring 4 Check the control device Some function is out of control 1 RS485 communication signal is not balance 2 Control protocol is not compatible 1 Connect 120Ω balance resistance 2 Reset protocol Unclear image 1 Focus is in manual state 2 Extreme zoom ...

Страница 20: ...All manuals and user guides at all guides com ...

Отзывы: