Accumulative Load Weight Function
•
With LED display showing load weight, press
“Black button”
to start accumulating loads
•
With last load weight lifted and shown on LED display by pressing
“RED button”
all individual
loads and total load weight will be shown.
If the onboard Bluetooth printer is used than all individual load weights and total will be printed
Overload Indication
•
The ED2E
-Elite
SkidWeigh series with
optional overload warning
will automatically show on
LED display the overload load value and display will “flash”. The audio / visual warning will be
activated to warn the operator of such condition. To stop the overload visual / audio overload
warning operator must lower the load to the ground.
Two Independent Weighing Channels
•
Use external mounted switch to utilize the two independent weighing channels function.
Example:
Standard forks and long forks weighing application
Note:
Weighing channel one is shown as a Mode 8 and second is shown as Mode 82.
Electric Pallet Truck Weighing Function
(
ED2E-EP
Skidweigh-Elite Series)
•
Turn on power switch
(ED2E-EP only)
. Insert forks into the load and lower it to the ground.
The LED display must show Mode 8.
•
Activate and hold vehicle lift control until lifting cylinder is automatically stopped
•
Weighing cycle will start, the LED display will go “blank” for the moment and load weight will
be shown. As soon the load weight is shown the lift motor motion control is disabled
•
Lift cylinder motion control will go back to normal operational mode
Note:
During normal operation where weighing function
is not required
turn the indicator
power switch ON /OFF to off position.
(The ED2E-EP system will be turned off)
Two Weighing Channels Switch
Channel 1 (showing Mode 8 on LED display)
Channel 2 (showing Mode 82 on LED display)
Mode 8