background image

PAGE 

!

 OF 

!

                                                                                                                                         VER. FLS3-4

2

2

     INTEGRATED VISUAL DATA TECHNOLOGY INC. 

3439 Whilabout Terrace, Oakville, Ontario, L6L 0A7  Canada 
Phone: 905-469-0985   Fax: 905-825-9494     skidweigh.com 

 Accumulative Load Weight Function 

  • 

With LED display showing load weight, press 

“Black button”

 to start accumulating loads

 

  • 

With last load weight lifted and shown on LED display by pressing 

“RED button”

 all individual 

loads and total load weight will be shown.                                                                                    

If the onboard Bluetooth printer is used than all individual load weights and total will be printed 

 

 

Overload Indication 

   

• 

The ED2E

-Elite 

SkidWeigh series with 

optional overload warning

 will automatically show on 

LED display the overload load value and display will “flash”. The audio / visual warning will be 

activated to warn the operator of such condition. To stop the overload visual / audio overload 
warning operator must lower the load to the ground.

  

   

Two Independent Weighing Channels 

  • 

Use external mounted switch to utilize the two independent weighing channels function. 

Example: 

Standard forks and long forks weighing application 

            

Note:

 Weighing channel one is shown as a Mode 8 and second is shown as Mode 82. 

Electric Pallet Truck Weighing Function

 

(

ED2E-EP

 Skidweigh-Elite Series) 

  • 

Turn on power switch 

(ED2E-EP only)

. Insert forks into the load and lower it to the ground.                 

                    

The LED display must show Mode 8. 

  

   • 

Activate and hold vehicle lift control until lifting cylinder is automatically stopped 

   • 

Weighing cycle will start, the LED display will go “blank” for the moment and load weight will 

be shown. As soon the load weight is shown the lift motor motion control is disabled  

  

 • 

Lift cylinder motion control will go back to normal operational mode                                                 

                                                                                                                                                            

Note:

 

During normal operation where weighing function

 is not required 

turn the indicator 

power switch ON /OFF to off position. 

(The ED2E-EP system will be turned off)

 

  

Two Weighing Channels Switch 

Channel 1 (showing Mode 8 on LED display) 
Channel 2 (showing Mode 82 on LED display)

Mode 8

ON /OFF Switch

Отзывы: