Ivation IVALDH70PWWP Скачать руководство пользователя страница 9

9

Removing Collected Water

There are two ways to remove collected water.

1.  Using the reservoir

•  When the unit is Off, if the reservoir is full, the unit will beep eight (8) 
 

times, the Full indicator light will flash, and the digital display will 

 show 

P2.

•  When the unit is On, if the reservoir is full, the compressor turns off and 
 

the fan turns off after 30 seconds to dry the water in the condenser. 

 

Then the unit will beep eight (8) times, the Full indicator light will flash, 

 

the digital display shows P2.

•  Slowly remove the reservoir. Grip the left and right handles securely, 
 

and carefully slide out straight so water does not spill. Do not rest it 

 

on the floor because the bottom of the reservoir is uneven. It will 

 

fall and cause the water to spill.

•  Discard water and replace the reservoir. The reservoir must be in 
 

place securely for the dehumidifier to operate.

•  The machine will re-start when the reservoir is restored in its correct position.

  NOTES: 
•  When you remove the reservoir, do not touch any parts inside of the unit. Doing so may 
 

damage the product.

•  Be sure to slide the reservoir gently all the way into the unit. Banging the reservoir against 
 

anything or failing to secure it may cause the unit not to operate.

•  When the reservoir is removed, if water remains in the unit, it must be dried.

2. Continuous draining

•  Water can be automatically emptied into a floor drain by attaching the 
 

unit with a water hose (Id≥ 5/16, not included) with a female threaded 

 

end (ID:M=1, not included).

•  Install the drain hose onto the adaptor (See illustration).

•  Remove the rubber cap from the back drain port of the unit and set 
 

aside, remove reservoir, then insert the drain hose through the drain 

 

port of the unit and securely press it into the connector on the front 

 

of the unit. (See illustration)

•  Tighten the adaptor and the unit by using two screws 
 

(placed in the reservoir).

•  Install the female threaded end of the water hose into the 
 

adaptor (See illustration), then lead the water hose to the 

 

floor drain or a suitable drainage facility.

•  Make sure the hose is secure so there are no leaks.

•  Direct the hose toward drain, making sure that there are 
 

no kinks to stop water flow.

•  Place the end of the hose into the drain and make sure the 
 

end of the hose is level or positioned in a downward direction to 

 

let the water flow smoothly. Do not raise the hose above the floor.

•  Place the reservoir back in the unit and make sure that it is 
 correctly 

secured.

•  Select the desired humidity setting and fan speed on the unit for 
 

continuous draining to start.

NOTE: When the continuous drain feature is not being used, remove the drain hose from port.

 

Drain hose

Adaptor 

Rubber cap

Connector

Drain hose

Water hose

Female thread
end 

Содержание IVALDH70PWWP

Страница 1: ...ibited For proper disposal there are several possibilities A Each municipality has established collection systems where electronic waste can be disposed of free of charge to the user B When buying a n...

Страница 2: ...NING This symbol indicates the possibility of death or serious injury CAUTION This symbol indicates the possibility of injury or damage to property Meanings of symbols used in this manual are as shown...

Страница 3: ...the unit You may be injured if you fall or if the unit falls over Do not place flower vases or other water containers on top of the unit Water may spill inside the unit causing insulation failure and...

Страница 4: ...Press to select either High or Normal fan speed Set the fan control to High for maximum moisture removal When the humidity has been reduced and quieter operation is preferred set the fan control to No...

Страница 5: ...nit will also shut off automatically For some models the fan motor will continue operating Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the fan will cont...

Страница 6: ...nt 1 Control Panel 2 Air Intake Vent 3 Air Outlet Vent 4 Air Filter behind vent 5 Water Reservoir 6 Handle on both sides Drain Hose 1 pc Adaptor 1 pc Screw 2 Pcs Back 1 Drain Hose Port 2 Caster 3 Powe...

Страница 7: ...difier must be operated in an enclosed area to be most effective Close all doors windows and other outside entrances or openings in the room Casters Casters move freely Do not force casters to move ov...

Страница 8: ...ll increase or decrease in 0 5 hour increments up to ten 10 hours and thereafter in one 1 hour increments up to 24 hours 3 The selected stop time will show in the LCD display in a few seconds The LCD...

Страница 9: ...risremoved ifwaterremainsintheunit itmustbedried 2 Continuousdraining Watercanbeautomaticallyemptiedintoafloordrainbyattachingthe unitwithawaterhose Id 5 16 notincluded withafemalethreaded end ID M 1...

Страница 10: ...cause an electric shock cause the insulation to deteriorate or cause the unit to rust The air intake and outlet vents get soiled easily so use a vacuum attachment or brush to clean 2 Clean the reservo...

Страница 11: ...lter is clogged The unit is tilted instead of upright as it should be The floor surface is not level Frost appears on the Coils This is normal The dehumidifier has an Auto defrost feature Water on flo...