![ivanti ISA6000 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/ivanti/isa6000/isa6000_hardware-manual_2096983006.webp)
Power: The main power switch is used to apply or remove power from the power supply to the server
system. Turning off system power with this button removes the main power but keeps standby power
supplied to the system. Therefore, you must unplug system before servicing.
Reset: The reset button is used to reboot the system.
Control Panel LEDs
The control panel displays five LEDs to monitor the system.
Information LED: Alerts operator of several states, as noted in the table below:
Status
Description
Continuously on and
red
An overheat condition has occurred. This may be caused by cable
congestion.
Blinking red (1Hz)
Fan failure; check for an inoperative fan.
Blinking red (0.25Hz)
Power failure; check for a non-operational power supply.
NIC1 (GLAN1): Associated with the Management port. It indicates network activity when flashing.
NIC2 (GLAN2): Unused. Will always be off.