background image

                                                                           

 

 

2

1.3

 

Specifications 

Specifications  

128-channel Series  

64-channel Series  

Main Processor  

SandyBridge i5 Socket 1155-
pin 32nm CPU 

SandyBridge i3 Socket 1155-
pin 32nm CPU 

Operation System 

Embedded LINUX system  

Power  

Support hot swap  

Fan  

Redundant  dual ball bearing fan 
MTBF>100 thousand hours 
Support online replacement.  

Memory  

4GB

Support extension

Server-level

With ECC 

verification

 

2GB

Support extension

Server-level

With ECC 

verification

 

Case 

1.2mm extra-thickness hot-dip galvanized steel. 
High accuracy aluminum alloy slider.  
Self-developed patent removable HDD bracket.  

User Interface  

WEB GUI 

 

Network Protocol  

RTP/RTCP, RTSP, UDP, HTTP, NTP, SNMP  

Audio/Video 
Connection  

128-channel standard 
definition or 64-channel high 
definition.  

64-channel standard 
definition or 16-channel high 
definition. 

Audio/Video 
Transmission  

128-channel standard 
definition or 32-channel high 
definition. 

64-channel standard 
definition or 16-channel high 
definition. 

Audio/Video 
Storage  

Based on 64-bit high-performance file system.  

Video Resolution  

1080P, 720P, D1, HD1, CIF, QCIF 

Audio/Video 
Search  

Based on data library and menu tree. Support various search 
engines.  

Audio/Video 
Setup 

Support one camera or a batch of camera setup at the same 
time.  

Record Policy  

Schedule record, manual record, alarm record 

Audio/Video 

Alarm Record 
Type 

Video loss, motion detect, camera masking, external alarm.  

HDD Amount 

16 SATA HDDs 

Max 2T space per HDD

 

HDD Mode 

One HDD, RAID0, RAID1, RAID5.

 

HDD Installation  

Additional HDD bracket, support HDD hot swap.  

Disk Array 
Enclosure/Backup 

Mini SAS port 3Gbps(Optional) 

Data 
Management  

HDD Hotspare  

Support global hotspare.  

Network Amount 

4 100/1000Mbps Ethernet ports  

Network 
Interface  

Network Port 
Feature 

Dual-network cards load balance binding or two independent 
1000-M Ethernet port.  

Power  

100V~240V

47~63Hz 

Total Power 
Consumption  

10W~200W

Including HDD

 

Working 
Temperature  

0 ~

50

 

Working Humidity 

5%~90%

Non-condense

 

Storage 
Temperature 

-20 ~70

 

Others 

Storage Humidity 

5%~90%

Non-condense

 

Содержание 128-channel Series

Страница 1: ...NVR Series User s Manual Version 2 2 1 ...

Страница 2: ...ont Panel 4 2 2 Rear Panel 5 2 3 Alarm Input and Output Connection 6 2 3 1 Alarm Input and Output Details 6 2 3 2 Alarm Input Port 7 2 3 3 Alarm Output Port 8 3 OVERVIEW OF NAVIGATION AND CONTROLS 9 3 1 Login 9 3 2 Main Menu 12 3 3 Search Playback 13 3 4 Information 15 3 4 1 HDD Information 16 3 4 2 BPS 18 3 4 3 Log 18 3 4 4 Version 19 ...

Страница 3: ... HDD Management 47 3 6 2 Abnormity 50 3 6 3 Alarm Output 51 3 6 4 Manual Record 51 3 6 5 Account 53 3 6 6 Auto Maintenance 55 3 6 7 Config Backup 56 3 6 8 RAID Management 56 3 7 Shutdown 57 4 SYSTEM UPGRADE 59 5 WEB OPERATION 60 5 1 General Introduction 60 5 1 1 Preparation 60 5 1 2 Log in 60 5 2 Main Interface 61 5 2 1 Monitor Channel Menu Tree 62 5 2 2 System Menu 64 5 2 3 Monitor Window Switch ...

Страница 4: ...5 3 Configuration 68 5 3 1 System Information 68 5 3 2 System Configuration 69 5 3 3 Advanced 85 5 3 4 Additional Function 94 5 4 Search 94 5 5 Alarm 97 5 6 About 98 5 7 Log out 99 APPENDIX H TOXIC OR HAZARDOUS MATERIALS OR ELEMENTS 100 ...

Страница 5: ...d to be a reference tool for the installation and operation of your system Here you can find information about this series NVR features and functions as well as a detailed menu tree Before installation and operation please read the following safeguards and warnings carefully ...

Страница 6: ... examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Environment The NVR should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc This series product shall be transported storage and used in the specified environments 6 Lithium ba...

Страница 7: ...devices z Can generate an email to notify the user when an alarm occurred Network Monitor z Transmit audio video data from the IPC or the NVS connected to the device to the network terminal simultaneously Delaying time is within 500ms Network bandwidth support needed z Max supports 20 connections z Adopt the following audio and video transmission protocol HTTP TCP UDP MULTICAST RTP RTCP and etc z ...

Страница 8: ...el standard definition or 16 channel high definition Audio Video Storage Based on 64 bit high performance file system Video Resolution 1080P 720P D1 HD1 CIF QCIF Audio Video Search Based on data library and menu tree Support various search engines Audio Video Setup Support one camera or a batch of camera setup at the same time Record Policy Schedule record manual record alarm record Audio Video Al...

Страница 9: ...3 Working Altitude 60m 3000m Dimensions 516 5mm without the LCD length 485mm With ear 133 2mm L W H Net Weight 20Kg front panel 0 4Kg Installation Mode Standard 19 inch rack installation ...

Страница 10: ...or a long time or pull out the power cable may result in device auto restart 2 System HDD Indication light The blue light flashes when system is reading or writing the system HDD In the system HDD there are device important configuration file factory default configuration file device initial boot up data 3 Alarm indication light The alarm indication light becomes on once an alarm occurred It becom...

Страница 11: ...nce an alarm occurred It becomes on via the software detection The alarm includes local alarm no disk and etc 4 Network indication light The network indication light is blue and it flashes when you connect the device to the network 5 USB port 6 16 HDD slot After you remove the front panel you can see there are 16 HDDs From the left to the right and from the top to the bottom it ranges from 1 4 5 8...

Страница 12: ...t normal open NO and normal close NC 1 Alarm input a Please make sure alarm input mode is grounding alarm input b Grounding signal is needed for alarm input c Alarm input needs the low level voltage signal d Alarm input mode can be either NC normal Open or NO Normal Close e When you are connecting two NVRs or you are connecting one NVR and one other device please use a relay to separate them 2 Ala...

Страница 13: ... and Rx RS232 port Tx is the data output cable and the Rx is the data input cable 2 3 2 Alarm Input Port Please refer to the following sheet for more information z Normal open or Normal close type z Please parallel connect COM end and GND end of the alarm detector Provide external power to the alarm detector z Please parallel connect the Ground of the NVR and the ground of the alarm detector z Ple...

Страница 14: ... 2A 125VAC 1A Maximum switch power 125VA 160W Maximum switch voltage 250VAC 220VDC Rating Resistance Load Maximum switch currency 1A Between touches with same polarity 1000VAC 1minute Between touches with different polarity 1000VAC 1minute Insulation Between touch and winding 1000VAC 1minute Surge voltage Between touches with same polarity 1500V 10 160us Length of open time 3ms max Length of close...

Страница 15: ...acter small capitalized and denotation Note For security reason please modify password after you first login Continuous three times login failure will result in system alarm and five times login failure will result in account lock Figure 3 1 After device booted up the system is in multiple channel display mode See Figure 3 2 Please note the displayed window amount may vary The following figure is ...

Страница 16: ...stem supports 1 4 8 9 16 25 36 64 window output mode Please select the window mode and then select the corresponding channels PTZ Setup The PTZ setup is shown as in Figure 3 5 Please note the commend name is grey once device does not support this function Double click the title to hide the PTZ menu interface Here you can control PTZ direction speed zoom focus iris preset tour scan pattern aux func...

Страница 17: ...ay setup button Please refer to chapter 3 5 7 for detailed information Device management You can use the channel list and the device list to manage the connected remote device The channel list is on the left Here you can view all connected channel information The green color in front of the camera name means current channel is recording now The grey color means current channel is not recording The...

Страница 18: ...6 1 for detailed information 3 2 Main Menu After you logged in the system main menu is shown as below See Figure 3 8 There are total seven icons search Information setting remote device backup advanced and shutdown Move the cursor to highlight the icon then double click mouse to enter the sub menu ...

Страница 19: ...rch item Search interface is shown as below See Figure 3 9 Please note the initial version does not support smart search card number search Figure 3 9 Please refer to the following sheet for more information SN Name Function 1 Display window zHere is to display the searched picture or file zSupport 1 4 9 16 window playback ...

Страница 20: ...r click the ENTER button to playback zYou can input the period in the following interface to begin accurate search zFile type R regular record A external alarm record M Motion detect record 6 Card number search The card number search interface is shown as below Right now system does not support this function Play Pause There are three ways for you to begin playback z The play button z Double click...

Страница 21: ... 32 files from one channel 11 Clip z It is to edit the file z Please play the file you want to edit and then click this button you can see the time control Select the start time and end time on the right side and click this button again you can see the backup data to be saved in the pop up dialogue box Click this button again to exit the clip mode 12 Record type In any play mode the time bar will ...

Страница 22: ...nd status See Figure 3 11 means current HDD is normal means there is no HDD If disk is damaged system shows as Please remove the broken hard disk before you add a new one Figure 3 11 In Figure 3 11 click view record d time button HDD record time information interface is shown as in Figure 3 12 ...

Страница 23: ... working HDD Physical port It is to display device connected physical port Type The corresponding HDD property Raid name It is to display RAID HDD name Total space The HDD total capacity Free space The HDD free capacity Status HDD can work properly or not Bad track Display there is bad track or not Page up Click it to view previous page Page down Click it to view the next page View recording time ...

Страница 24: ...ist System max displays 100 logs in one page It can max save 1024 log files Please use page up down button on the interface or the front panel to view more z Backup Please select a folder you want to save you can click the backup button to save the log files After the backup you can see there is a folder named Log_time on the backup path Double click the folder you can see the log file z Details C...

Страница 25: ... Here is for you to view some version information See Figure 3 16 Please note the following interface is based on the 128 channel series product and it is for reference only z Channel z Alarm in z Alarm out z System version z Build Date z Web ...

Страница 26: ...or block one user if you have proper system right Figure 3 17 3 4 6 Remote Device Information Here you can view the channel status of the remote device connection log and network balance information and etc Channel status Here you can view the IPC status of the corresponding channel such as motion detect video loss camera masking alarm and etc See Figure 3 18 ...

Страница 27: ...u can search the IPC log information of the corresponding channel It includes IPC online offline and etc See Figure 3 19 Figure 3 19 Network Balance Here you can view network data transmission speed receive speed See Figure 3 20 Figure 3 20 3 5 Setting ...

Страница 28: ... z Time format There are two types 24 hour mode or 12 hour mode z Language Here is to display current language name z HDD full Here is for you to select working mode when hard disk is full There are two options stop recording or rewrite If current working HDD is overwritten or the current HDD is full while the next HDD is no empty then system stops recording If the current HDD is full and then nex...

Страница 29: ...n interval here to synchronize the NVR time and IPC time Note Since system time is very important do not modify time casually unless there is a must Before your time modification please stop record operation first After completing all the setups please click save button system goes back to the previous menu Figure 3 22 Figure 3 23 Figure 3 24 3 5 2 Encode Encode setting includes the following item...

Страница 30: ...een Channel display You can select system displays channel number or not when you playback Please click set button and then drag the title to the corresponding position in the screen z Snapshot Click snapshot button you can set snapshot mode picture size quality and frequency See Figure 3 26 Before the snapshot operation please make sure the front end device supports current operation Snapshot mod...

Страница 31: ...25 Figure 3 25 Figure 3 26 Figure 3 27 ...

Страница 32: ...ng Click it you can see an interface shown as in Figure 3 31 Here you can set holiday date Check the box it means current channel shall record as your holiday setup Please go to the Period interface to set the holiday date record setup Please highlight icon to select the corresponding function After completing all the setups please click save button system goes back to the previous menu At the bot...

Страница 33: ...e Figure 3 32 z Network Mode It includes multiple address fault tolerance and load balancing Multiple address mode eth1 and eth2 and etc operate separately Max support 4 network ports You can use the services such as HTTP RTP service via eth1 2 3 4 Usually you need to set one default card default setup is eth1 to request the auto network service form the device end such as DHCP email FTP and etc N...

Страница 34: ...mask Gateway display as zero You need to disable DHCP function to view current IP information Besides when PPPoE is operating you can not modify IP Subnet mask Gateway z IP version There are two options IPv4 and IPv6 Right now system supports these two IP address format and you can access via them z TCP port Default value is 37777 You can change if necessary z UDP port Default value is 37778 You c...

Страница 35: ...he list supports max 64 IP addresses Figure 3 34 3 5 4 3 NTP Setup You need to install SNTP server Such as Absolute Time Server in your PC first In Windows XP OS you can use command net start w32time to boot up NTP service NTP setup interface is shown as in Figure 3 35 z Host IP Input your PC address z Port This series NVR supports TCP transmission only Port default value is 123 z Update interval ...

Страница 36: ... 9 Sydney GMT 10 Hawaii GMT 10 Alaska GMT 9 Pacific Time P T GMT 8 American Mountain Time M T GMT 7 American Central Time C T GMT 6 American Eastern Time E T GMT 5 Atlantic Time GMT 4 Brazil GMT 3 Middle Atlantic Time GMT 2 Figure 3 35 3 5 4 4 Multiple Cast Setup Multiple cast setup interface is shown as in Figure 3 36 Figure 3 36 Here you can set a multiple cast group Please refer to the followin...

Страница 37: ...space Except the above mentioned addresses of special meaning you can use other addresses For example Multiple cast IP 235 8 8 36 Multiple cast PORT 3666 After you logged in the Web the Web can automatically get multiple cast address and add it to the multiple cast groups You can enable real time monitor function to view the view 3 5 4 5 PPPoE PPPoE interface is shown as in Figure 3 37 Input PPPoE...

Страница 38: ...on Device IP is not fixed if you use ADSL to login the network The DDNS function allows you to access the NVR via the registered domain name Besides the general DDNS the Quick DDNS works with the device from the manufacturer so that it can add the extension function 2 Function Introduction The Quick DDNS client has the same function as other DDNS client end It realizes the bonding of the domain na...

Страница 39: ...tion of the device z Status When the UPNP is offline it shows as Searching When the UPNP works it shows Success z Router LAN IP It is the router IP in the LAN z WAN IP It is the router IP in the WAN z Port Mapping list The port mapping list here is the one to one relationship with the router s port mapping setting z Enable Switch It shows that the function of port mapping is enabled in this port z...

Страница 40: ...rt English character and Arabic number Max 32 digit z Receiver Please input receiver email address here System max supports 3 email boxes z SSL enable System supports SSL encryption box z Interval The send interval ranges from 0 to 3600 seconds 0 means there is no interval z Health email enable Please check the box here to enable this function This function allows the system to send out the test e...

Страница 41: ...ent activates the email system sends out the email according to the interval you specified here This function is very useful when there are too many emails activated by the abnormity events which may result in heavy load for the email server Figure 3 41 Figure 3 42 3 5 4 9 Alarm center It provides alarm center host IP port and alarm upload time setup The interface is reserved for the users to deve...

Страница 42: ...up For example the work day ranges from 8 30 17 30 Monday to Friday and then you set the period 7 10 18 00 for Monday So the arm period of the Monday ranges from 7 10 to 18 00 Please highlight the corresponding button to enable this function z PTZ activation When an alarm occurred system can activate the PTZ operation The PTZ activation lasts an anti dither period In the Pan Tilt Zoom interface Ma...

Страница 43: ...il to alert you when alarm occurs z Record channel you can select proper channel to record alarm video Multiple choices You need to set alarm record mode as Schedule in Record interface Main Menu Advanced Record Please note the manual record has the highest priority System record all the time no matter there is an alarm or not if you select Manual mode Now you can go to the Schedule interface Main...

Страница 44: ...38 Figure 3 44 Figure 3 45 Figure 3 46 ...

Страница 45: ...the motion detection zone Black zone is the disarmed zone You can click Fn button to switch between the arm mode and disarm mode In arm mode you can click the direction buttons to move the green rectangle to set the motion detection zone After you completed the setup please click ENTER button to exit current setup Do remember click save button to save current setup If you click ESC button to exit ...

Страница 46: ...ce is shown as in X305H305H305HFigure 3 50X Click PgUp PgDn to set more channels z Record Delay System can delay the record for specified time after alarm ended The value ranges from 10s to 300s z Tour Here you can enable tour function when alarm occurs System one window tour Please go to chapter 3 5 7 Display for tour interval setup Please highlight icon to select the corresponding function After...

Страница 47: ...41 Figure 3 49 Figure 3 50 Figure 3 51 ...

Страница 48: ...Figure 3 53 Camera Masking When someone viciously masks the lens or the output video is in one color due to the environments light change the system can alert you to guarantee video continuity Camera masking interface is shown as in Figure 3 54 You can enable alarm output channel and then enable show message function Tips You can enable preset tour pattern activation operation when video loss occu...

Страница 49: ...wo options 1280 1024 default 1920 1080 Please note the system needs to reboot to activate current setup z Enable tour Activate tour function z Interval System supports 1 4 8 9 16 window tour Input proper interval value here The value ranges from 5 120 seconds In tour process you can use mouse or click Shift to turn on window switch function Stands for opening switch function stands for closing swi...

Страница 50: ...n after channel You can see an interface shown as in Figure 3 57 Click PgUp PgDn to view more channels Please note all your modification here applies to local end only You need to refresh web or client end to get the latest channel name System max support 25 digital character ...

Страница 51: ...ystem pops up a dialogue box You can highlight to restore default factory setup z Select all z General z Encode z Schedule z RS232 z Network z Alarm z Detect z Pan tilt zoom z Display z Channel name Please highlight icon to select the corresponding function After all the setups please click OK button system goes back to the previous menu Warning System menu color language time display mode video f...

Страница 52: ...t to remove z Manual add Click it to add the IPC manually The default port number is 37777 if the manufacture is Private The default user name is admin and password is admin Figure 3 59 Click the Manual Add button you can go to the following interface See Figure 3 60 This series product max supports 32 channel standard definition video high definition non real time video and the transmission rate ...

Страница 53: ...ent alarm output abnormity manual record account auto maintenance configuration backup and RAID management Figure 3 61 3 6 1 HDD Management Here is for you to view and implement hard disk management See Figure 3 62 You can see current HDD type status capacity and record time When HDD is working properly system is shown as O When HDD error occurred system is shown as X ...

Страница 54: ...r you can erase all data in the HDD Please note system needs to reboot to get all the modification activated Figure 3 62 Figure 3 63 For the HDD group setup operation please note z Each channel s records can be stored into the specified HDD Group z Each HDD Group is corresponding to several hard disks while one hard disk is only included in one HDD Group z Each channel is only corresponding with o...

Страница 55: ... current hard disk When you are setting the HDD Group please choose the corresponding HDD Group number from the dropdown list and save the settings Figure 3 64 Important HDD group here refers to the HDD port number it does not change in case you replace the HDD System needs to reboot to activate current setup after you set new HDD setup HDD Channel Setting Click the button named with Channel Setti...

Страница 56: ...lect alarm activation output port multiple choices z Latch Here you can set corresponding delaying time The value ranges from 1s 300s System automatically delays specified seconds in turning off alarm and activated output after external alarm cancelled z Show message system can pop up the message in the local screen to alert you when alarm occurs z Alarm upload System can upload the alarm signal t...

Страница 57: ...u Right click mouse on the preview mode or in the main menu from Advanced Manual Record you can see manual record menu is shown as in Figure 3 68 You can click the PgUp PgDn button to view more channels 3 6 4 2 Basic operation There are two modes main stream and extra stream There are three statuses schedule manual stop Please highlight icon to select corresponding channel z Manual The highest pri...

Страница 58: ...l schedule record Please highlight ALL after Schedule See Figure 3 70 When system is in schedule recording all channels will record as you have previously set Main menu Setting Schedule The corresponding indication light in front panel will turn on Figure 3 70 z All channel manual record Please highlight ALL after Manual See Figure 3 71 When system is in manual recording all scheduled set up you h...

Страница 59: ...z Modify user z Add group z Modify group z Modify password For account management please note z For the user account name and the user group the string max length is 6 byte The backspace in front of or at the back of the string is invalid There can be backspace in the middle The string includes the valid character letter number underline subtraction sign and dot z System account adopts two level m...

Страница 60: ...iew without login z One user should belong to one group User right can not exceed group right z About reusable function this function allows multiple users use the same account to login After all the setups please click save button system goes back to the previous menu Figure 3 73 3 6 5 1 Modify Password Click password button the interface is shown as in Figure 3 74 Here you can modify account pas...

Страница 61: ...gure 3 75 Figure 3 75 3 6 5 3 Add Modify User Click add user button the interface is shown as in Figure 3 76 Please input the user name password select the group it belongs to from the dropdown list Then you can check the corresponding rights for current user For convenient user management usually we recommend the general user right is lower than the admin account The modify user interface is simi...

Страница 62: ...e button system goes back to the previous menu Figure 3 77 3 6 7 Config Backup The configuration file backup interface is shown as below See Figure 3 78 This function allows you to copy current system configuration to other devices Figure 3 78 3 6 8 RAID Management This interface is for you to manage RAID disk display RAID name type free space total space status and etc You can add or delete RAID ...

Страница 63: ...m pops up a dialogue box for you to select See Figure 3 81 z Logout menu user log out menu You need to input password when you login the next time z Restart application reboot device z Shutdown system shuts down and turns off power z Restart system system begins rebooting z Switch user you can use another account to login If you shut down the device you can see system begins saving data and then s...

Страница 64: ...58 Please note you can view the corresponding dialogue box if you have no right to turn off the device Figure 3 81 ...

Страница 65: ...n not update via port 3777 Then you can use port 3800 to update 2 Click the Login button on the right side system pops up a dialogue box Here you can input user name admin and password admin Click the OK button you can login And you can see the Login button becomes Logout 3 Click the Open files button and then select the upgrade file click the BIOS button to update Figure 4 1 Or you can use the fl...

Страница 66: ...roduct max supports 4 network adapters The default setup is eth1 192 168 1 108 eth2 192 168 1 101 eth3 192 168 1 102 and eth4 192 168 1 103 z Use order ping NVR IP address to check connection is OK or not 5 1 2 Log in Open the IE and then input the NVR IP address in the address column For example if your NVR IP address is 10 10 3 16 then please input http 10 10 3 16 in IE address column See Figure...

Страница 67: ...w See Figure 5 3 Figure 5 3 Login interface Please input your user name and password Default factory name is admin and password is admin Note For security reasons please modify your password after you first login 5 2 Main Interface NVR web main interface is shown as in Figure 5 4 ...

Страница 68: ...z Section 2 System menu z Section 3 PTZ control z Section 4 Video setup and other setup z Section 5 Preview window z Section 6 Monitor window switch 5 2 1 Monitor Channel Menu Tree The monitor channel menu tree is shown as in Figure 5 5 Please note the following figure is for reference only ...

Страница 69: ...l 1 to channel 128 64 Local play Click local play button to select file to play in PC Refresh Click this button to refresh monitor channel name Please left click one monitor to view real time video the monitor window is shown as in Figure 5 6 Figure 5 6 Real time Monitor Please refer to the following sheet for monitor window parameter information ...

Страница 70: ... folder picture download default Please initial version does not support this function Audio Turn on or off audio Close video Close video in current window 5 2 2 System Menu System menu is shown as in Figure 5 7 Please refer to chapter 5 3 Configuration chapter 5 4 Search chapter 5 5 Alarm chapter 5 6 About chapter5 7 Log out for detailed information Figure 5 7 System Menu 5 2 3 Monitor Window Swi...

Страница 71: ...Z setup button Please note open menu close menu up down left right confirm cancel buttons are for speed dome only z PTZ direction PTZ supports eight directions left right up down upper left upper right bottom left bottom right z Speed The step 8 speed is faster than step 1 Figure 5 10 PTZ Interface Click PTZ set button the interface is shown as in Figure 5 11 You can click this icon to display or ...

Страница 72: ...tton to remove one preset from the tour Pattern You can input pattern value and then click start record button to begin PTZ movement Please go back to Figure 7 10 to implement camera operation Then you can click stop record button in Figure 7 11 Now you have set one pattern Assistant The assistant items include BLC Digital zoom night vision camera brightness flip z You can select one option and th...

Страница 73: ...terface is shown as in Figure 5 13 Figure 5 13 Color and More Please refer to the following sheet for detailed information Parameter Function Picture Path Click picture path button system pops up an interface for you to modify path Record Path Click record path button system pops up an interface for you to modify path Reboot Click this button to reboot device If there is local use logged in the sy...

Страница 74: ...ware version information Please note the following figure is based on our 128 channel series product and it is for reference only See Figure 5 14 Figure 5 14 Version Information 5 3 1 2 HDD information Here you can view local storage status such as free capacity and total capacity See Figure 5 15 Figure 5 15 HDD Information ...

Страница 75: ...inish time Set time to finish search Search You can select log type from the drop down list and then click search button to view the list Clear You can click this button to delete all displayed log files Please note system does not support clear by type Backup You can click this button to backup log files to current PC 5 3 2 System Configuration Please click save button to save your current setup ...

Страница 76: ...or detailed information Parameter Function System Time Here is for you to modify system time Please click Save button after your completed modification Sync PC You can click this button to save the system time as your PC current time Data Format Here you can select data format from the dropdown list ...

Страница 77: ...value ranges from 1 to 120 minute Default setup is 60 minutes Device No When you are using one remote control to manage multiple devices you can give a serial numbers to the device Please note current series product does not support this function Video Standard Here you can view video format such as PAL 5 3 2 2 Encode The encode interface is shown as in Figure 5 20 Figure 5 20 Encode Please refer ...

Страница 78: ...etter the image quality Reference bit is an ideal range for you to set bit rate Overlay Cover area z Here you can privacy mask the specified video in the monitor video z One channel max supports 4 privacy mask zones The privacy mask includes two options Never monitor Never It means do not enable privacy mask function Monitor the privacy mask zone can not be viewed in monitor mode Time display z Yo...

Страница 79: ...73 Figure 5 22 Schedule Time Figure 5 23 Copy Figure 5 24 ...

Страница 80: ...er complete setup please go back to Figure 5 21 and then click save to save current time period setup Holiday Click Set button system pops up a dialogue box shown as in Figure 5 24 Here you can set holiday date Check the box it means current chann shall record as your holiday setup Please go to the Period interface to set the holiday date record setup Copy It is a shortcut menu button You can copy...

Страница 81: ...ing number to input IP address Then you can set the corresponding subnet mask the default gateway Default Gateway Here you can input the default gateway TCP Port Default value is 37777 You can change if necessary HTTP Port Default value is 80 RTSP port Default value is 554 UDP Port Default value is 37778 You can change if necessary Max Connection Network user max amount The value ranges from 0 to ...

Страница 82: ...iguration is saved and the device will auto connect to Internet The IP address is the WAN IP z There are two conditions for reboot z 1 The user must have the authority to reboot device z 2 There is no user login the system menu on the local end z After PPPOE dial succeed get the current IP address and visit this IP address via WEB Email The email interface is shown as in Figure 5 27 ...

Страница 83: ...er IP that can parse the domain SSL enable You can enable SSL encryption function to guarantee data safety Port Default value is 25 You can modify it if necessary User Name The sender email account user name Password The sender email account password Sender Sender email address Subject Input email subject here Max 32 digit Address Input receiver email address here Max input three addresses Interva...

Страница 84: ...DNS and Client end Introduction 1 Background Introduction Device IP is not fixed if you use ADSL to login the network The DDNS function allows you to access the DVR via the registered domain name Besides the general DDNS the Quick DDNS works with the device from the manufacturer so that it can add the extension function 2 Function Introduction The Quick DDNS client has the same function as other D...

Страница 85: ...ress Important z Do not register frequently The interval between two registrations shall be more than 60 seconds Too many registration requests may result in server attack z System may take back the domain name that is idle for one year You can get a notification email before the cancel operation if your email address setup is OK NTP The NTP interface is shown as in Figure 5 29 Here you can realiz...

Страница 86: ... alarm centre server IP port number Once there is an alarm occurred system can notify the alarm centre as you specified here Figure 5 30 Alarm Centre UNPN Go to the UPnP interface you can see an image is shown as in Figure 5 31 It allows you to establish the mapping relationship between the LAN and the public network Here you can also add modify or remove UPNP item Figure 5 31 UNPN ...

Страница 87: ...81 5 3 2 5 Alarm Alarm setup interface is shown as in Figure 5 32 Figure 5 32 Alarm Setup Figure 5 33 PTZ Setup ...

Страница 88: ...e alarm can last until the IPC and the NVR connection resumes Alarm in Select corresponding alarm channel Enable You need to draw a circle here so that system can detect the alarm signal Type There are two options normal open and normal close NO becomes activated in low voltage NC becomes activated in high voltage Period z Alarm record function becomes activated in the specified periods z There ar...

Страница 89: ...il to alert you when alarm occurs and ends Screen display After enabled alarm info will be prompted out on the local output end That is to say the alarm prompt will be displayed beside the channel name on the local surveillance image Buzzer Once you check the box here the buzzer beeps when an alarm occurred Tour z Display the selected video in local monitor window When alarm occurs system can begi...

Страница 90: ...fore exit to save the setup Period Here you can set for business day and non business day Anti dither Range 0 600 Alarm output s when alarm occurred system enables peripheral alarm device Record channel Select the recording channel can be selected more than once this channel will be activated to record when alarm occurs Please note you need to set the motion detect record period in the Schedule in...

Страница 91: ... 36 Please note system can not restore some information such as network IP address Figure 5 36 Default and Backup Please refer to the following sheet for detailed information Parameter Function Select All Restore factory default setup Export Configuration Export system configuration to local PC Import Configuration Import configuration from PC to the system 5 3 3 Advanced 5 3 3 1 HDD Management Pl...

Страница 92: ...D as read write Read only Set current HDD as read Redundant Set current HDD as redundant HHD Recover Fix the HDD error Right now the device does not support this function 5 3 3 2 RAID Management This interface is for you to manage RAID disk display RAID name type free space total space status and etc You can add or delete RAID disk here See Figure 5 38 Figure 5 38 ...

Страница 93: ...utton in Figure 5 38 you can go to the following interface to add or delete hotspare disk See Figure 5 41 Figure 5 39 5 3 3 3 Abnormaliity The interface is shown as in below See Figure 5 40 and Figure 5 41 Figure 5 40 Abnormality 1 ...

Страница 94: ...alarm output can delay for the specified time after alarm stops The value ranges from 10s to 300s Record channel After you selected the disk connection option once the device is offline the activated channel can begin alarm record Record latch System can delay the record for specified time after alarm ended The value ranges from 10s to 300s Send email If you enable this function system can send ou...

Страница 95: ...r detailed information Parameter Function Alarm output The value 1 8 here refers to alarm output channels The interface here is for reference only Please click the corresponding number and then click the trigger button Trigger Enable disable alarm output Please note once you activate an alarm manually you need to click the output channel number again and then click trigger button to disable it Oth...

Страница 96: ...s auto record function as you set in schedule setup chapter 5 3 2 3 Manual Enable corresponding channel to record no matter what period applied in the record setup Stop Stop current channel record no matter what period applied in the record setup 5 3 3 6 Account Here you can add remove user or modify password See Figure 5 44 ...

Страница 97: ...ser Please refer to the following sheet for detailed information Parameter Function User Input the user name of the new established account Reusable The reusable account means that this account can be used in more than one PC at the same time ...

Страница 98: ...vely 5 3 3 7 Snapshot Snapshot interface is shown as in Figure 5 46 Figure 5 46 Please refer to the following sheet for detailed information Parameter Function Channel It is the monitor channel Snapshot mode There are two modes Timing and activation Frame rate You can select from the dropdown list The value ranges from 1f s to 7f s Resolution You can select from the dropdown list Quality You can s...

Страница 99: ...and auto delete old files interval from the dropdown list See Figure 5 47 Figure 5 47 Auto Maintenance 5 3 3 9 Remote device Remote device interface is shown as in Figure 5 48 Figure 5 48 Remote device Please refer to the following sheet for detailed information ...

Страница 100: ...egment and the device shall disable the firewall Type Select remote device type here IP address port remote channel Please input remote device IP address port number remote device channel number and account manually User password Please input account to login the remote device 5 3 4 Additional Function 5 3 4 1 Auto register The auto register interface is shown as in Figure 5 49 You can set the ser...

Страница 101: ...and the blue highlighted date means it has record files Figure 5 50 Search Then please click search button you can see the corresponding files in the list See Figure 5 51 Figure 5 51 Select the file s you want to download and then click download button system pops up a dialogue box shown as in Figure 5 52 then you can specify file name and path to download the file s to your local pc ...

Страница 102: ...up In Figure 5 53 there is a remote back pane at the left bottom of the pane It allows you to backup the record or picture to your local USB storage media via the Web remotely Click the search button you can view the available storage device See Figure 5 54 Please select from the dropdown list and then begin the backup Please refer to chapter 5 2 6 to set device download path ...

Страница 103: ...r your reference 5 5 Alarm Click alarm function you can see an interface is shown as in Figure 5 55 Here you can set device alarm type and alarm sound setup When alarm occurs system can display the alarm information in the corresponding interface For motion detect video loss camera masking you need to set the event in the motion detection interface Current series product does not support this func...

Страница 104: ...vice and can activate NVR local operation Alarm Type IPC offline alarm System can generate an alarm when the front end IPC disconnects with the local NVR Listening alarm System notifies web when alarm occurs you select from the above event type and then web can notify user Video When alarm occurs system auto enables video monitor This function only applies to video detection alarm motion detection...

Страница 105: ...99 Figure 5 56 About 5 7 Log out Click log out button you can go back to log in interface See Figure 5 57 Figure 5 57 Alarm ...

Страница 106: ...od the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such kind of substances or elements please return to the corresponding local authorities to process according to your lo...

Отзывы: