4. INSTALLATION

Positioning and Mechanical Requirements

1.   For maximum effectiveness, position the Phoenix as close as possible to the charged 

surface to be neutralized.  Direct the air stream longitudinally, and in the same 

direction as, the target material movement to maximize the time the charged surface 

remains in the air stream.  Ensure that the ionized air stream covers the entire 

target surface, and that the material to be neutralized is not in direct contact with a 

background surface.

2.   The Phoenix can be placed on any flat, level surface using the built-in bench stand.  

It can also be wall or ceiling mounted using the tapped mounting holes in the base of 

the stand.  The Phoenix may also be placed on an OPTIONAL vertically adjustable 

floor stand that can be moved and positioned as required.

Electrical Connections

1.  The Phoenix requires 120 VAC, 60 Hz or 230 VAC, 50/60 Hz for operation. 

Depending on the model, terminate line cord with plug if required.  Connect the line 

cord to a 3-terminal grounded receptacle.

2.  The unit MUST be grounded for ionization to occur.

NOTE

 – Do not attempt to operate at voltages other than those specified.

NOTE

 – For 230 VAC, 50/60 Hz units, performance is slower for 230 VAC  

50 Hz operation by approximately 20%.

CAUTION – Fire Hazard

Do not install or operate equipment in close proximity to any flammable solvents 

or in explosive atmospheres.

Содержание SIMCO-ION Phoenix

Страница 1: ...Phoenix Ionizing Blower 5200632 Rev E Phoenix Ionizing Blower INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...ix Ionizing Air Blower 120 VAC 3 Phoenix Ionizing Air Blower 230 VAC 4 4 INSTALLATION 5 Positioning and Mechanical Requirements 5 Electrical Connections 5 5 OPERATION 6 6 TROUBLESHOOTING 7 Operational Check 7 Ion Balance Adjustment 7 7 MAINTENANCE 8 Front Screen 8 Ionizing Emitter Points 8 Air Intake Filters 8 8 REPLACEMENT PARTS ADDITIONAL ITEMS 9 9 WARRANTY 9 ...

Страница 3: ...instruction manual before installing or operating equipment 2 Only qualified service personnel are to perform installation and repairs 3 All equipment must be properly grounded including the machine frame to which the equipment is mounted 4 Do not operate device in excess of specifications NOTE Do not attempt to operate at voltages other than those specified NOTE Do not allow dust dirt or debris t...

Страница 4: ...a bench stand to aid in directing the ionized air stream An optional floor stand with wheels is also available Receipt of Equipment 1 Carefully remove the equipment from its carton 2 Inspect contents for damage that may have occurred during shipment If any damage has occurred the local carrier should be notified at once A report should be forwarded to Simco Ion 2257 North Penn Road Hatfield PA 194...

Страница 5: ...e Air Speed Characteristics 2 000 FPM at 1 ft fan speed high 1 250 FPM at 2 ft fan speed high 800 FPM at 4 ft fan speed high Noise Level 68 dB at high fan speed 2 ft from blower Ionization Indicator Status lamp illuminates when high voltage is present at the emitter points Short Circuit Current 0 175 mA max emitter point to ground Typical Discharge Times 0 5 sec at 1 ft 5000V to 500V 1 0 sec at 2 ...

Страница 6: ...cs 2 000 FPM at 1 ft fan speed high 1 250 FPM at 2 ft fan speed high 800 FPM at 4 ft fan speed high Noise Level 68 dB at high fan speed 2 from blower Ionization Indicator Status lamp illuminates when high voltage is present at the emitter points Short Circuit Current 0 175 mA max emitter point to ground Typical Discharge Times 0 5 sec at 1 ft 5000V to 500V 1 0 sec at 2 ft 5000V to 500V 2 0 sec at ...

Страница 7: ...bench stand It can also be wall or ceiling mounted using the tapped mounting holes in the base of the stand The Phoenix may also be placed on an OPTIONAL vertically adjustable floor stand that can be moved and positioned as required Electrical Connections 1 The Phoenix requires 120 VAC 60 Hz or 230 VAC 50 60 Hz for operation Depending on the model terminate line cord with plug if required Connect ...

Страница 8: ...to the desired airflow setting Use the highest airspeed that the application allows With the fan speed set to maximum the Phoenix will neutralize static charges at a distance of ten feet As the fan speed is decreased neutralization range will also decrease NOTE Do not allow dust dirt or debris to block or obstruct the airflow inlets or outlets CAUTION Electrical Shock Hazard Always disconnect powe...

Страница 9: ...or your local Simco Ion Representative NOTE Never use a spark test to check operation The balancing circuit design of the Phoenix makes the spark test inconclusive and can permanently damage the circuit Ion Balance Adjustment 1 An electronic balancing circuit in the blower controls the output ration of negative to positive ions The circuit is preset at the factory and normally requires no further ...

Страница 10: ...ill reduce the effectiveness of the blower The ionization points must be cleaned periodically to prevent deposits from accumulating 2 Simply turn OFF the unit and slide the built in Point Cleaner located on the front face of the blower from one side to the other and back again 3 Frequency of cleaning should be at least once monthly or as determined by inspections based on operating conditions Air ...

Страница 11: ...d PA 19440 transportation prepaid and insured for its replacement cost Prior to returning any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equipment has been tampered with misused improperly installed altered has received damage through abuse carelessness...

Страница 12: ...Phoenix Ionizing Blower 5200632 Rev E Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2015 Simco Ion Printed in the U S A ...

Отзывы: