SERVICE SETTINGS
3 OF 3
RETURN
ACCESS CODE:
----
STOP
1:
0 m/min
123
3
Manual #50-14 Revised 8/08
Page 4-- 33
C. 1998
PC-Communication Setup (Option)
Use this menu to select RS232 or RS485 data protocol
and adjust the baud rate.
Note!
This menu is functional only when the
Data Option (X30) has been installed.
Press button 2.
Enter Access Code if this function is
protected.
Press Enter Button.
Use buttons F1 or F2 to select the item to be
changed.
Press buttons F2 or F3 to change the
selected item.
Press Enter Button.
Repeat this procedure for each parameter to be
changed.
Note!
If the RS485 Interface is activated,
the Slave Address is adjustable.
Press F4 to return to previous menu.
Change Profibus Address (Option)
Use this menu to change the Profibus address.
Note!
This menu is functional only when the
Profibus Option (X28 & X29) has been
installed.
Press button 3.
STOP
1:
0 m/min
2:
0 m/min
3:
0 m/min
PC COMMUNICATION MENU
Baudrate :
Port
:
4:
0 m/min
RETURN
1,2 k
RS 232
Содержание DY 2008
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 82: ...Appendix A pg 4 ITW Dynatec c 2003 Revised 2 05 DY2008 Controller Manual 50 14 ITW Dynatec c 2005 ...
Страница 91: ...ITW Dynatec c 2003 Appendix B pg 9 DY2008 Controller Manual 50 14 Revised 1 09 ...
Страница 92: ...Appendix B pg 10 ITW Dynatec c 2003 Revised 1 09 DY2008 Controller Manual 50 14 c 2003 ITW Dynatec ...
Страница 98: ...Appendix C pg 6 ITW Dynatec c 2003 Revised 8 08 DY2008 Controller Manual 50 14 c 2003 ITW Dynatec ...