background image

 INSTALLATION MANUAL SCALA 3000 

 
 
 

Position the switch as indicated in the figure 

– Adjust the TIME selector to the minimum until it stops in anti-clockwise rotation 
– Adjust the operating distance with the SENS selector 

     

– Put an object at the desired distance 

If the sensor does not detect the object (LED ON) 
      

– Turn the SENS selector clockwise until the LED light goes off 

 

– Turn the SENS selector slightly counterclockwise until the LED lights up 

If the sensor detects the object (LED OFF) 
      

– Turn the SENS selector counterclockwise until the LED lights up 

      

– Remove the object 

Adjust the TIME selector two stripes clockwise past the MIN 

 

Содержание SCALA 3000 COMPACT

Страница 1: ...INSTALLATION MANUAL SCALA 3000 COMPACT ...

Страница 2: ...y The drain pipes of the unit should not be siphoned at any time the water should drain without problems In addition there is a shut off valve with tap for emptying the water tank 21 mm diameter or 38 mm diameter depending on the unit The machinery must be hoisted with care not to move the gear motor on the evaporator Use a lift or crane with straps using the unit s base Keep in mind that the air ...

Страница 3: ...and another to start stop the water evaporator cooler In addition it has LEDs indicating Reducer gear Full of ice Cooler gear Thermal reducer failure Thermal compressor failure Lack of water Remote box For the connection a signal cable is required 12x1 mm2 The cable is connected to the terminal board of the remote panel and from there to the terminal board in the box of the condenser unit of the g...

Страница 4: ... 3000 Terminal box condenser unit generator In addition there are two outputs to power the cooler evaporator which is located in the chamber upper part to cool the water that goes to the generator Use a 3x1 5 mm2 cable to feed ...

Страница 5: ...L 2 Phase N 3 Reduction gear 4 Reduction gear 5 Full ice photocell 6 Full ice photocell 7 Thermal reducer 8 Thermal compressor 9 Lack of water 10 Lack of water 11 Stop start generator 12 Stop start generator 13 Cooler 14 Cooler Q Circuit breaker 10A Heater thermostat ...

Страница 6: ...install the cooler we recommend making a bypass system to be able to cancel it if necessary Below we show photos of an installation for two Scala 3000 units Mounting pipes with bypass in covered shed Cooler housing The water tank has an upper overflow pipe to avoid possible overflow of water float valve as well as a key in the lower part for emptying the water tank It is advisable to install a dra...

Страница 7: ...lines to come out by the rotation of the milling cutter that causes the ice to fall from the evaporator wall You have to make a drop to drive the ice into the box It is usually a hopper outlet and then flow into the silo It can be in stainless or food PVC The drop must have an adequate slope so do not make an exit of more than 30 to prevent the ice from caking Below are photographs taken in a stai...

Страница 8: ...e chamber to stop the ice falling if the fall is completely conducted it is not necessary since it stops just below the evaporator which has the stop photocell for full of ice Here is how the photocell connects A 5x1 mm2 hose is needed to feed the photocell and the signal from the location of the photocell to the electrical panel of the ice generator ...

Страница 9: ...ector Put an object at the desired distance If the sensor does not detect the object LED ON Turn the SENS selector clockwise until the LED light goes off Turn the SENS selector slightly counterclockwise until the LED lights up If the sensor detects the object LED OFF Turn the SENS selector counterclockwise until the LED lights up Remove the object Adjust the TIME selector two stripes clockwise pas...

Страница 10: ...s The evaporator panel comes with a speed variator which allows modifying the frequency of rotation of the motor allowing speeds below 50Hz factory parameter achieving thicknesses greater than 1 5 mm and up to 3 mm The production loss is not more than 20 at a speed of about 30 Hz We do not advise lowering more than 30 Hz The variable speed drive also has the function of heat gear motor It is respo...

Страница 11: ...rgency stop Fc Photocell Ip Main switch PW Lack of water pressure switch Ta Start timer SL Solenoid liquid Ra Starter relay Mr Gear motor Mb Water pump Pd Remote stop Rs External relay signal free voltage I Thermal II Pump running III Full tank IV No water V Motor gear running ...

Отзывы: