20
Keep pressed the button while switching on main front switch. Wash cycle is activated and only
the water recirculation pump is running. There is a maximum time for this cycle of 30 min. After
this time, pump stops.
Wash cycle is finished by switching off main power.
Read cleaning and sanitizing instructions for proper usage of this function.
4.4 DRAIN FORCE
4.4.1 SEQUENCE OF OPERATION
While the machine is turn on, there is water that need to be evacuated between each cycle. There are 2
possible outlet water, one is if the ice in the storage bin melts (#1) and the other is when the production
time ends, the water electrovalve opens and fills the water tray(#2) to renovate the water. The excess of
water goes out by the overflow (#3) to the drain force water reservoir (#4).
When the water reservoir is full of water covering the 2 electrodes (#5), the pump (#6) turns on and
evacuates water for 5 seconds. After 5 seconds, the pump turns off if the electrodes are not covered by
the water, otherwise, the pump will start again for 5 seconds.
In case that the system does not work for any issue, the water will flood the ice bin. There is a ventilation
tube (#7) that allows the system to remove any air that may remain in the water reservoir. The Vent tube
must be always over the mouth of the front door (#8).
In case that the pump works for 5 min continuously, it will stop for 5 seconds automatically in order to
refrigerate.