Electrical and Ambient Temperature Ratings
Minimum ambient temperature is -40 °C (-40 °F), except with
B Option which is -26°C (-15°F)
Form C3X and CC3X are suitable to 82 °C (180 °F)
11 amp @ 125 or 250 VAC; 5 amp @ 125 or 250 VAC;
5 amp resistive , 3 amp inductive @ 28 VDC;
0.5 amp resistive @ 125 VDC
Form C3MX or CC3MX (M Option) suitable to 82 °C (180 °F):
1 amp @ 125 VAC
Form C6N (SPDT):
11 amp @ 125 or 250 VAC to +75 °C (+167 °F) max, T5;
11 amp @ 125 or 250 VAC to +60 °C (+140 °F) max, T6;
5 amp @ 125 or 250 VAC, 5 amp resistive , 3 amp inductive
@ 28 VDC; 0.5 amp resistive @ 125 VDC to +70 °C
(+158 °F) max, T6.
Form CC6N (DPDT):
11 amp @ 125 or 250 VAC to +65 °C (+176 °F) max, T4;
11 amp @ 125 or 250 VAC to +45 °C (+116 °F) max, T6;
5 amp @ 125 or 250 VAC; 5 amp resistive , 3 amp inductive @
28 VDC; 0.5 amp resistive, @ 125 VDC to +70 °C (+158 °F)
max, T6.
Form C6MN or CC6MN (SPDT or DPDT with M Option):
1 amp @ 125 VAC to +70 °C (+158 °F) max. T6