ITT neo-dyn 100p Скачать руководство пользователя страница 2

 

 

Enclosure 6N Pressure Switches 

Page i

  

Manual No. 610-0010 REV G 

Neo-Dyn

®

 

28150 Industry Drive 

Valencia, CA 91355 

Tel: (661) 295-4000 

Fax: (661) 294-1750 

World Wide Web: www.neodyn.com 

©Copyright 2002 

ITT Industries 

Important Information 

The product warranty applicable to this ITT Neo-Dyn

®

 instrument is as stated on page the last 

page of this manual. 

Should any after-delivery problems arise, please contact ITT  Neo-Dyn’s Customer Service 

using the information above. Our normal business hours are weekdays, 7:00 am to 3:30 PM, 

Pacific Time. 

Before installing this Pressure Switch, become familiar with the installation and adjustment 

instructions in Chapters 2 and 3 

WARNING 

Indicates a hazard which can cause severe personal injury, death, or substantial 

property damage if the warning is ignored.

 

CAUTION 

Indicates a hazard which will or can cause minor personal injury or property damage if the 

caution is ignored. 

SPECIAL CONDITIONS 

FOR SAFE USE 

 

The electrical snap switch assemblies shall be installed such that the equipment wiring is 

protected from mechanical damage by the use of metal conduit or a method providing 

equivalent protection. The equipment wiring must not be subjected to tension or torque. If it is 

to be terminated within a potentially explosive atmosphere, a suitably certified termination 

facility must be used.

 

 

NOTE 

Indicates additional information about a particular item necessary to the operation of the unit. 

This document contains proprietary information, which is the property of Neo-Dyn

®

, a unit of 

ITT industries. This document may not be reproduced, either in part or in full, without the 

consent of ITT industries. 

 

Содержание neo-dyn 100p

Страница 1: ...N MODELS 100P 110P 142P 180P 200P ADJUSTABLE PRESSURE SWITCHES MODEL 160P ADJUSTABLE DIFFERENTIAL PRESSURE SWITCHES ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES INSTALLATION AND OPERATION MANUAL PN 610 0010...

Страница 2: ...injury death or substantial property damage if the warning is ignored CAUTION Indicates a hazard which will or can cause minor personal injury or property damage if the caution is ignored SPECIAL COND...

Страница 3: ...IGURATIONS 2 CHAPTER 2 INSTALLATION 3 MOUNTING 3 PROCESS CONNECTIONS 4 PROCESS MEDIA 4 POTENTIALLY EXPLOSIVE ATMOSPHERES HAZARDOUS LOCATIONS 5 ELECTRICAL CONNECTIONS 5 CHAPTER 3 ADJUSTMENTS AFTER INST...

Страница 4: ...e a polyimide Kapton sensing diaphragm nitrile O ring and aluminum alloy or corrosion resistant steel CRES pressure port CRES diaphragms and all welded constructions are also available in some models...

Страница 5: ...re Switches that are not covered in this manual you can contact Neo Dyn or our representatives in several ways The Neo Dyn customer service phone number is 661 295 4000 Our customer service department...

Страница 6: ...NG Do not remove switch while under pressure MOUNTING The Pressure Switch can be mounted directly to the process connection if there is no significant vibration and the fluid lines are capable of supp...

Страница 7: ...ipe joint sealing compound CAUTION Avoid excessive torque on all threaded connections WARNING Do not exceed the marked maximum operating pressure in normal operation WARNING Do not use as a safety dev...

Страница 8: ...tandard with a green wire grounded to the case 72 inch 183 cm leads are available as R Option and other lead lengths may be ordered as special configurations The leads are intended for installation in...

Страница 9: ...check the increasing setpoint of a pressure switch connect a pressure source and a calibrated pressure gauge or transducer to the pressure port and slowly apply increasing pressure or vacuum on Model...

Страница 10: ...Switch If application of pressure or vacuum 10 greater than the adjusted setpoint fails to produce actuation first check for contamination in the process connection and verify that the expected press...

Страница 11: ...erfaces Weight approximately 3 pounds 1 4 kg each Conduit Connection 14 NPT male Standard Pressure Port Wetted Material 1 18 NPT female Wetted Materials 4 9 14 NPT female Models 160P both ports and 18...

Страница 12: ...umber Breakdown Wetted Materials Table 1 No Description 1 Aluminum alloy port Teflon coated polyimide Kapton diaphragm and nitrile O ring 1 Aluminum alloy port and piston Teflon seal Nitrile O ring on...

Страница 13: ...06 9 5000 344 8 100P 5 6N 5 3000 206 9 5000 344 8 100P 7 6N 7 3000 206 9 5000 344 8 100P 8 6N 8 3000 206 9 5000 344 8 Pressure Ratings Model 110P Table 3 Part No Range No Max Operating Pressure psig b...

Страница 14: ...11250 776 200P18 6N 8 10000 690 15000 1034 200P18 6EN 8 9500 655 15000 1034 Pressure Ratings Model 160P Table 6 Part No Range No Max Operating Pressure psig bar Proof Pressure psig bar 160P 2 6N 2 30...

Страница 15: ...and Ambient Temperature Ratings Minimum ambient temperature is 40 C 40 F except with B Option and Kalrez O rings it is 26 C 15 F Form C6N SPDT 11 amp 125 or 250 VAC to 70 C 158 F max T5 11 amp 125 or...

Страница 16: ...erials 100P 110P 160P 180P 200P C EPR O Ring Refer to Wetted Materials 100P 110P 160P 180P 200P E 7 16 20 SAE Port Wetted Material 1 Only 100P 200P except Range 8 G 14 NPT Male Port 110P Wetted Materi...

Страница 17: ...pped prepaid C Exclusion from Warranty THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS OR OTHERWISE Components manufactured by...

Отзывы: