ITT

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Copyright (c) 2009 ITT Corporation

Goulds Pumps and the ITT Engineered Blocks Symbol are  
registered trademarks and tradenames of ITT Corporation.

Engineered for life

HYDROQSG 

July, 2009

www.goulds.com

100

 

SUBMENU

BASIC SET

TINGS

200

 

SUBMENU

CONF INVERTER

300

 

SUBMENU

REGULA

TION

400

 

SUBMENU

SENSOR

500

 

SUBMENU

SEQUENCE CNTR

100

 

SUBMENU

BASIC SET

TINGS

60

 

SUBMENU

SET

TINGS

200

 

SUBMENU

CONF INVERTER

300

 

SUBMENU

REGULA

TION

400

 

SUBMENU

SENSOR

500

 

SUBMENU

SEQUENCE CNTR

61

 

PAS

SWORD

 

0000

105

 

MODE

 

Controller

202

 

SOF

TW

ARE

 

HV V01.3

205

 MAX. 

UNITS

 

6

210

 

INVERTER

 

ALL

215

 

RAMP 1

 

4 sec

225

 

RAMP 3

 

70 sec

260

 

FMIN TIME

 

0 sec

265

 

BOOST

 

5 %

310

 

WINDOW

 

10 %

510

 

ACT

.V

AL.DEC

 

2 PSI

540

 

DROP FREQ

 

42.0 Hz

410

 CONF SENSOR

 

Sensor 1

315

 HYSTERESIS

 

80 %

515

 ENABLE FREQ

 

48 Hz

545

 

OVERV

AL

UE

 

disabled

415

 

SENSOR TYPE

 

analog I 4-20mA

320

 REG. MODE

 

normal

520

 

ENABLE DL

Y

 

5 sec

550

 

OVERV

AL DL

Y

 

0 sec

420

 SENS. RANGE

 

300 PSI

325

 

FRQ. LIF

T

 

30.0 Hz

525

 

SWITCH DL

Y

 

2 sec

555

 

SWITCH INTV

 

24 hours

425

 

SENS. CURVE

 

linear

330

 LIF

T AMOUNT

 

0.0 %

530

 DISABLE FRQ

 

30.0 Hz

560

 

SYNCH.LIM.

 

0.0 Hz

565

 

SYNCH.WIN.

 

2 Hz

570

 MSTPRIORITY

 

ON

430

 SENS1 CAL 0

 

0 % = x,xx PSI

440

 

SENS2 CAL 0

 

0 % = x,xx PSI

435

 

SENS1 CAL X

 0 % = xx,xx PSI

445

 

SENS2 CAL X

 0 % = xx,xx PSI

285

 

SKIPFRQ CTR

 

0.0 Hz

270

 KNEE FREQ.

 

60 Hz

286

 SKIPFRQ RNG

 

60 Hz

275

 POWER RED.

 

OFF

290

 

CURR. LIMIT

 

OFF

280

 

SEL.SW

.FRQ.

 

Auto

291

 

CURR. LIMIT

 

100 %

230

 

RAMP 4

 

70 sec

235

 RAMP FMIN A

 

2 sec

240

 RAMP FMIN D

 

2 sec

245

 MAX. FREQ

 

60 Hz

250

 MIN. FREQ

 

20 Hz

220

 

RAMP 2

 

4 sec

203

 

SET VER INV

sel. 01

 

act. 01

106

 PUMP ADDR

 

1

110

 SET P

AS

SW

.

 

0066

115

 L

OCK FUNCT

.

 

0066

120

 DISP

. CONTR.

 

75 %

125

 DISP

. BRIGHT

 

100 %

62

 

JOG

 

Hz

 

50 PSI

305

 

JOG

 

Hz

 

50 PSI

505

 

ACT

.V

AL.INC

 

5 PSI

535

 

DISABLE DL

Y

 

5 sec

405

 

DIMENS. UNIT

 

PSI

255

 CONF

. FMIN

 

F  > 0

1000

 

SUBMENU

TESTRUN

800

 

SUBMENU

REQUIRED V

AL

UES

700

 

SUBMENU

OUTPUTS

1000

 

SUBMENU

TESTRUN

1100

 

SUBMENU

SETUPS

1100

 

SUBMENU

SETUPS

605

 

MIN.THRESH.

 

disabled

705

 

ANAL

OG OUT1

Output frequency

1005

 

TESTRUN

 

100 hours

610

 

DELA

Y TIME

 

2 sec

1010

 TESTRUN FREQ.

 

30 Hz

710

 

ANAL

OG OUT2

Actual value

810

 

C.REQ.V

AL.2

 

OFF

1120

 

PAS

SWORD 2

 

0000

907

 

OFFS.INPUT

 

100

1210

 

BA

UDRA

TE

 

9600

1215

 

FORMA

T

 

RTU N81

830

 

ACTU

A

T.FRQ1

 

0.0 Hz

1220

 

PUMP ADDR

 

1

835

 

ACTU

A

T.FRQ2

 

0.0 Hz

805

 

C.REQ.V

AL.1

 

digital

1110

 

FACTORY SET

 

USA

905

 

OFFS.INPUT

 

OFF

1205

 

ADDRES

S

 

1

615

 

ERROR RESET

 

ON

1015

 

TESTR.BOOST

 

10 %

715

 

CONF REL 1

 

Running

815

 

SW REQ.V

AL

 

Setpoint 1

1125

 

CLR ERRORS

 

ALL

910

 

LEVEL 1

 

0

915

 

LEVEL 2

 

100

1020

 

TESTR.TIME

 

5 sec

720

 

CONF REL 2

 

Errors

820

 

REQ.V

AL.1

 

50 PSI

1130

 CLR MOTORH.

 

ALL

912

 

OFFSET X1

 

0

917

 

OFFSET X2

 

100

1025

 

SEL.DEVICE

 

01

1030

 

TESTRUN MAN

 

Press > 3 sec

825

 

REQ.V

AL.2

 

50 PSI

1135

 

CLR OPERA

T.

 

Press > 3 sec

913

 

OFFSET Y1

 

0 PSI

918

 

OFFSET Y2

 

0 PSI

800

 

SUBMENU

REQUIRED V

AL

UES

600

 

SUBMENU

ERRORS

600

 

SUBMENU

ERRORS

700

 

SUBMENU

OUTPUTS

1200

 

SUBMENU

RS485-INTERF

ACE

1200

 

SUBMENU

RS485-INTERF

ACE

900

 

SUBMENU

OFFSET

900

 

SUBMENU

OFFSET